Thermo-Paramagnetic Oxygen Analyzer - Michell XTP501
- Non-Depleting Rugged Paramagnetic Sensor
- Features
-
- Compact, lightweight and easy to install
- Intuitive user interface
- Tough IP55 housing
- Low cost of ownership due to minimal maintenance
- Measurement ranges from 0 to 1% up to 0 to 25% O2 and 20/80/90-100% O2
- Accuracy of better than ±1% full scale
- 2 x 4–20 mA outputs and MODBUS RTU over RS485 protocol as standard
Oxygen Combustion Control Analyzer - Michell XZR500
- Robust Long-Life MSRS Zirconia Sensor
- Features
-
- Measurement range: 0.01 to 25% O2
- Various probe for stack temperatures up to 1,300°C
- No air reference required with our Metallic Sealed Reference Sensor
- Long life zirconia cell with reliable accurate measurements
- Simple to maintain, easy to calibrate every 6 months
- Robust design that is simple to use
- Quick and easy to install
Oxygen Analyzer for Gas Purity Measurements - Michell XZR400
- Fast Responding With Metallic Sealed Reference Sensor
- Features
-
- Fast response time
- Simple and easy operation
- Low maintenance and cost of ownership
- No need for reference air
- Barometric pressure compensation
- Multiple Outputs available from 4-20 mA, RS485 Modbus RTU and RS232
- Rack, wall-mount, bench-mount, and transportable versions available
- Optional built-in Easidew Transmitter with rack-mount version
Oxygen Analyzer - Michell XTP601
- Low Maintenance O2 Measurement
- Features
-
- General purpose or ATEX, IECEx, CCSAUS, TC, TR & Ex hazardous area certified models
- Meets the requirements of IEC61508 SIL 2
- Ranges available: 0–0.5% up to 0–50% & 20, 80 or 90–100%
- Touch-screen display allows calibration or adjustment without the need for a hot works permit
- Intrinsic error (accuracy) is better than 1% full scale
- Zero span stability better than 0.25% of span per month
- Outputs include RS485 and two 4-20mA (following NAMUR NE 44 standard)
- Low cost of ownership due to minimal maintenance and no consumable parts
-Features of Fixed Ambient Oxygen Deficiency Monitors with Alarms
Low maintenance with typically 32 months oxygen sensor life
Audible and visual oxygen deficiency alarm available
Up to four measurement ranges
Accuracy of <2% of span
Mains power with battery back-up (GPR-35)
Remote oxygen sensor & pump options (GPR-35)
Analog output for connection to DCS
12-28 V DC operation (GPR-2500 versions)
Cost-Effective Oxygen Analyser for Combustion - OXY-FLEX Series
- Long-Life, Non-Depleting Oxygen Measurement
- Features
-
- Configurable outputs: 4-20 mA and 0 to 10 V DC or RS232 comms interface
- Cycling 3.3 V DC logic output allows direct monitoring of the O2 sensor for diagnostic purposes
- Can be calibrated in normal air (20.7% O2) or in any other known O2 concentration
- Selectable output filtering allows fast and dynamic or slow and stable output
- Externally triggered automatic or manual calibration
- Diecast aluminium case IP65 with stainless steel probe
- Sample temperature up to +400°C
AII GPR-3500 MOVR Portable Purity Oxygen Analyzer
-Accuracy: < 2% at constant conditions
Analysis Ranges: 0-100% Auto-ranging or manual lock on a single range
Application: Continuous monitoring of oxygen levels up to 100% O2
Not flow sensitive
Power: Rechargeable battery, 60 day cycle, 8 hrs with pump
Sensor Model: GPR-11-120-OP
Temp. Range: -10ºC to 45ºC
Area Classification: General purpose only
AII GPR-3500 MO Portable Oxygen PurityAnalyzer
-Accuracy: < 2% of FS range under constant conditions, e.g. constant temperature, flow rate and ambient pressure
Analysis: 0-100% FS range
Application: Intermittent monitoring of oxygen levels up to 100% O2
Area Classification: General purpose
Not flow sensitive
Pressure: Inlet - regulate to 5-30 psig to deliver 1-2 SCFH flow;
vent - atmospheric
Power: Rechargeable battery, 60 day cycle
Sample System: Flow indicator & control valve
Sensitivity: < 0.5% of FS range
Sensor Model: GPR-11-120-RTS
Operating Range: 5ºC to 45ºC
AII GPR-35 Ambient Oxygen Monitors
-Accuracy: < 2% of reading under constant conditions
Analysis: 0-25% FS ranges
Application: Monitor oxygen content of ambient atmospheres or confined spaces where oxygen depletion is a concern
Area Classification: General purpose (Category, II; pollution degree, 2)
Flow: Sampling - not applicable to ambient monitoring
Power: 100/110/220/240 VAC with fluctuation not to exceed +10%; battery back-up on trickle charge; battery life 30 days normal mode or 8 hours in alarm mode
Operating Range: 0º to 45ºC
Alarms: Two adjustable SPDT Form C non-latching relay contacts, preset to OHSA 20.0% Caution, 19.5% Danger settings
AII GPR-3100 Oxygen Purity Analyzer
-Accuracy: < 2% of FS range under constant conditions, e.g. constant temperature, flow rate and ambient pressure: +5% with temperature fluctuation of +10°F
Accuracy: < 1% of FS range at constant conditions; inherent accuracy of 0.1% following calibration with 95-100% oxygen
Analysis: 90-100%, 80-100%, 50-100% and 0-100% or 0-5%, 0-10%, 0-25% and 0-100%; Auto-ranging or fixed single range
Application: Continuous analysis of high purity oxygen concentrations up to 100% oxygen in inert, He, H2 and mixed gases
Area Classification: General purpose
Connections: Compression tube fittings 1/4" inlet, 1/4” vent or Compression tube fittings 1/8" inlet, 1/4” vent
Not flow sensitive
Pressure: Inlet - regulate to 5-30 psig to deliver 2 SCFH flow; vent – atmospheric
Power: Universal; specify 100/110 or 200/220 VAC for heater system
Sensitivity: < 0.1% oxygen
Temp. Range: 5ºC to 45ºC
AII GPR-2900 Oxygen Analyzer With Remote Sensor
-Accuracy: < 2% of FS range under constant conditions
Analysis: 0-1%, 0-5%, 0-10%, 0-25% FS ranges; optional 0-1%, 0-5%, 0-10%, 0-100% FS ranges: auto-ranging or fixed single range
Application: Oxygen analysis in inert, helium, hydrogen, mixed and acid (CO2) gas streams
Area Classification: General purpose
Flow: Not flow sensitive
Pressure: Inlet - regulate to 5-30 psig to deliver 1-2 SCFH flow; vent – atmospheric
Power: Universal; specify 100/120/220/240 VAC or 12-28 VDC
Sensor Model: non-acid (CO2) gas streams or gases containing > 0.5% CO2
Temp. Range: 5ºC to 45ºC (GPR sensor); -10ºC to 45ºC (XLT sensor)
AII GPR-2800 Process Oxygen Analyzers
-Accuracy: < 2% of FS range under constant conditions
Analysis: 0-1%, 0-5%, 0-10%, 0-25% FS ranges; auto-ranging or fixed single range or 0-25% O2 FS ranges
Application: Oxygen analysis in hazardous ambient areas and confined spaces
Area Classification: Certified for use in hazardous areas
Connections: 1/8" or 1/4" compression tube fittings
Enclosure: NEMA Type 3R for rain in outdoor applications (UL) NEMA 4X (ATEX)
Flow: Not flow sensitive
Pressure: Inlet - regulate to 5-30 psig to deliver 1-2 SCFH flow; vent – atmospheric or Atmospheric
Power: 18-24 VDC or 12-28 VDC (UL, ATEX Certified), 110-220 VAC (ATEX Certified)
Sensor Model: GPR for non-acid (CO2) gas streams; XLT for gases containing > 0.5% CO2
Operating Range: 5ºC to 45ºC (GPR sensor); -10º to 45ºC (XLT); -10ºC to 45ºC (GPR sensor)