Weather Shields - Rotronic AC Series
-Type: Naturally ventilated
Probe diameter: Ø 15; Ø 25
Number of plates: 9;10;21
Dimension: Ø 130 x 140 mm; Ø 130 x 160 mm; Ø 130 x 215 mm
Compatible probes: HC2A-(S)3; MP100A/400A; MP102H/402H
Water Activity Probe - Rotronic HC2-AW
-Operating ranges: Humidity 0...1 aw / 0…100 %rh Temperature -40…85 °C
Output signal: Digital UART or USB
Accuracy at 23 °C: Humidity ±0.008 aw / ±0.8 %rh / Temperature ±0.1K
Dimensions: 60mm / ∅ 68mm
Water Activity Meter - AW-THERM
-Operating conditions: 1...40 °C
Measurement range: 0.005...1.000 aw
Accuracy: ±0.005 aw (10...30 °C), ±0.1 °C
Temperature control range: 0...60 °C
Interface: Micro USB
Trace Moisture Transmitter - Michell Pura
- Hygrometer For Trace Moisture in Pure Gases
- Features
-
- Measurement range down to -120°Cdp (1ppbV)
- Stable and repeatable measurement
- Analog and digital output
- Simple installation
- VCR process connections
- Optional display / alarm unit
- Compact design
- Fast response
- Optional Hazardous Area Approval
- Service exchange program
Self-Contained Hygrometer- Michell Drycheck
- Simple Dew-Point Measurement in Wide Measurement Range
- Features
-
- Integrated instrument and sampling system
- Simple installation
- Wide measurement range
- Dew point or moisture content
- Analog output, display and dual alarms
- IP65 (NEMA 12) enclosure
Self-Calibrating Trace Moisture Analyzer - Michell QMA401
- Low Maintenance Quartz Microbalance Technology
- Features
-
- Precision measurement from 0.1 to 2000ppmV
- Fast response in both dry to wet and wet to dry transitions
- Simple, low cost, on-site maintenance with long service intervals
- Dryer can be replaced by the user in 10 minutes
- Accuracy of 0.1ppmV or 10% of reading, whichever is greater
- Intuitive user interface
- Ethernet or USB digital communications
- SD card data logging
- Optional internal sample handling and bypass loop
-Type: Service Cable
Used: For programming (setting, scaling, firmware update). Requires HW4/HW5
Range of application: -40…70 °C
Cable Length: 1.8m/3.6m
Connector A Side: USB
Rotronic PCMini52 - Digital RH Mini Probe with Temperature output
-Accuracy: ±2 %rh (10...90 %rh), ±0.2 K @ 23 °C
Application range: 0…100 %rh, -20…80 °C
Stability: ±1 %rh/year
Output signal: Modbus RTU 0 to 1, 0 to 5, 0 to 10 V
Power supply: 14…35 VDC (0…5 V/0…10 V output) 6…35 VDC (0…1 V output)
Rotronic PC62 & PC62V – digital relative humidity and temperature probe
-Accuracy: ± 2 %rH (10…90 % rH)
Application range: 0…100 %rh, -20…80 °C
Stability: ±1 %rh/year
Output signal: 0–1, 0–5, 0–10 V, RS232, RS485
Power supply: 14…30 VDC (0…5 V/ 0…10 V output) 5…30 VDC (0…1 V)
Rotronic PC52 - Analog RH and Temperature Probe
-Accuracy: ±2 %rh (10…90 %rh) / ±0.2 K
Application range: -20…80 °C / 0…100 %rh
Stability: ±1 %rh/year
Output signal: 4–20 mA, 0 to 1, 0 to 5, 0 to 10 V
Power supply: 14…30 VDC (0…5 V/ 0…10 V output); 5…30 VDC (0…1 V & mA output)
Rotronic PC33 - Analog RH and Temperature Probe
-Accuracy: ±3 %rh (30...80 %rh), ±0.3 K @ 23 °C
Application range: 0…100 %rh, -20…80 °C
Stability: ±1 %rh/year
Output signal: 4–20 mA, 0 to 1, 0 to 5, 0 to 10 V
Power supply: 14…30 VDC (0…5 V/ 0…10 V output); 5…30 VDC (0…1 V & mA output)
RH and Temperature Probe Calibrator - Rotronic HygroGen 2
-Control probe specification ±0.8 %RH (10…30 °C), ±2 %RH (0…60 °C) ±0.1K (10…30 °C), ±0.3K (0…60 °C)
Working volume: 1.5 litres 17 litres
Typical calibration uncertainty: ±1.5 %RH (k=2) at 23 °C, ±0.15 °C (k=2) 15...50 °C
Sensor: HygroClip2, capacitive RH sensor, Pt100 temperature sensor
Generation method Mixed flow with desiccant drier cell and piezoelectric humidifier; Peltier thermoelectric element with radial chamber mixing fan

-350x280.jpg)
-350x280.jpg)





-350x280.jpeg)