Standard Thermocouple Model 1600

- The type R and S standards will cover the range from 0°C to 1600°C.

- The measuring assembly comprises a 7mm x 300mm or 600mm gas tight 99.7% recrystallized alumina sheath inside which is a 2.5mm diameter twin bore tube holding the thermocouple.

- Type R and Type S

- Gas Tight Assembly

- Premium Grade Wire

Brief specifications


More details

The Isothermal range of Thermocouple Standards are the result of many years development. The type R and S standards will cover the range from 0°C to 1600°C. The measuring assembly comprises a 7mm x 300mm or 600mm gas tight 99.7% recrystallized alumina sheath inside which is a 2.5mm diameter twin bore tube holding the thermocouple. The inner 2.5mm assembly is removable since some calibration laboratories will only accept fine bore tubed thermocouples and some applications require fine bore tubing. The covered noble metal thermocouple wire connects the measuring sheath to the reference sheath which is a 4.5mm x 250mm stainless steel sheath suitable for referencing in a 0°C reference system. Two thermo electrically free multi-strand copper wires (teflon coated) connect the thermocouple to the voltage measuring device. The thermocouple material is continuous from the hot or measuring junction to the cold, or referencing junction.


ВимірюванняГенерація (Імітація)


Документация

Standard Thermocouple Model 1600

- The type R and S standards will cover the range from 0°C to 1600°C.

- The measuring assembly comprises a 7mm x 300mm or 600mm gas tight 99.7% recrystallized alumina sheath inside which is a 2.5mm diameter twin bore tube holding the thermocouple.

- Type R and Type S

- Gas Tight Assembly

- Premium Grade Wire

Featured Products

Additel 286 Multifunction Reference Thermometer Readout
Additel 286 Multifunction Reference Thermometer Readout
The Additel 286 Multifunction Reference Thermometer Readout is an industry first We have combined the capabilities of a high-end reference thermometer with a highly capable data acquisition system and 8.5 digit multimeter. The ADT286 is cap...
Код: ADT286
Standard Resistors
Standard Resistors
Eventually all resistance thermometry refers back to one or more fixed resistors. These are a key element in any laboratory which measures temperature. The resistors need to be very stable with time, temperature and transportation, and they...
Код:
PROCAL -TRACK laboratory management software
PROCAL -TRACK laboratory management software
ProCal-Track provides tools for the management of instruments from goods inwards through to despatch and all points in between. ProCal-Track can be used independently of ProCal, or can be integrated for full laboratory automation. Ease of u...
Код: PROCAL
Hyperion 4936
Hyperion 4936
Need advice on which model? Dry Block Selection Guide The Hyperion and Drago (30°C to 250°C) have large calibration volumes, 65mm x 160mm deep, which makes them ideal to use as portable liquid baths for high accuracy calibration of awkwardl...
2.0000/5 1text_less_review
Код: 4936
MPG2-H Manual Hydraulic Pressure Regulator
MPG2-H Manual Hydraulic Pressure Regulator
MPG2-H is a compact, easy-to-use and economical system for manually generating and adjusting pressure from atmosphere to as high as 200 MPa (30 000 psi) in systems where precise pressure adjustment is required. MPG2-H is very well suited f...
Код: MPG2-H
Isorac Model 844
Isorac Model 844
The function of this reference unit differs from other rack mounted systems in that the temperature of the metal block in which the thermocouple and copper leads are inserted actually varies with ambient temperature. A separate output signa...
Код: 845
Handheld Humidity Meters – Rotronic HYGROPALM HP-GTS
HygroPalm HP-GTS Measuring device for paper industry - Humidity and Temperature Measurement The HP-GTS from Rotronic is a tried-and-tested instrument for measurement of equilibrium relative humidity and temperature in stacks of paper and c...
Код: HP-GTS
2271A Pressure Controller & Calibrator
2271A Pressure Controller & Calibrator
The Fluke Calibration 2271A Industrial Pressure Calibrator provides a complete, automated solution for calibrating a wide variety of pressure gauges and sensors. Thanks to its modular design, it can be configured to meet different needs and...
Код: 2271A
8410A Portasal
8410A Portasal
The 8410A Portasal™ is a portable, high precision instrument from the world leader in Salinometers. This instrument will deliver salinity calculations on-board ship with laboratory level accuracy. PRODUCT FEATURES Completely Portable Yet Of...
Код: 8410A
AII GPR-18
The GPR-1800 series of intrinsically safe trace oxygen analyzers are designed for use in demanding process environments where the low detection limit down the AII’s industrial oxygen sensors can be well utilized. Typical for Analytical Indu...
Код: GPR-18
IOHOSE-NP2 Pneumatic hose
IOHOSE-NP2 Pneumatic hose
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Safe area use 2 m/3.28 ft pneumatic hose. Maximum pressure 20 bar/300 psi...
Код: IOHOSE-NP2
Isotech Model 96178 HTSPRT
Isotech Model 96178 HTSPRT
Isotech has produced over 200 high temperature thermometers which have been sold world-wide for use up to the silver point. As a consequence of our predelivery testing alone we have probably made more silver point calibrations than anyone e...
Код: 96178
ADROIT6200 DA Output Pressure Sensors
ADROIT6200 DA Output Pressure Sensors
The next generation pressure sensor One Sensor. No Compromises. Discover ADROIT6200 - the first release of ADROIT6000 industrial pressure sensors family. ADROIT6200 is a high performance, robust pressure measurement device. It combin...
Код: ADROIT6200
TRU Model 938
TRU Model 938
The TRU (Thermocouple Reference Unit) supplies a stable and accurate 0°C, or elevated reference temperature. It is a self-contained all solid-state unit using Peltier technology which provides maintenance free operation. The TRU features ra...
Код: 938
TRUrac Model 847
TRUrac Model 847
Thermocouple Reference System The TRUrac is a 0°C or elevated temperature thermocouple reference system mounted in a 19” chassis. It has been developed for situations where ambient temperature can be up to 65°C. The reference temperature is...
Код: 847
ADT685 Digital Pressure Gauge
ADT685 Digital Pressure Gauge
Looking for the most advanced, best performing and modern digital pressure gauge on the market? Congratulations, you’ve just found it! Additel’s ADT685 digital pressure gauges are in a class of their own with an amazingly easy to use and re...
Код: ADT685
9041A transportable multiproduct calibrator
9041A transportable multiproduct calibrator
The 9000A series range of multiproduct calibrators offers the widest workload of any calibration system presently available. The 9000A series provides all of the functionality of the 3000A series multiproduct calibrator in a dedicated rugge...
4.4000/5 5text_lot_review
Код: 9041A
ADT793 Pressure Controller & Generator
ADT793 Pressure Controller & Generator
The Additel 793 pressure controller combines the latest control/measure technology, modular design and easy to use/maintenance features into a single users friendly device. The Additel 793 provides pressure control up to 15,000 psi (1,000 B...
Код: ADT793
Oberon R Model 426
Oberon R Model 426
The Oberon R uses a Sodium heat Pipe to ensure an exceptionally low temperature gradient along the furnace core. It is ideal for the realization of Aluminium, Silver or Copper ITS-90 Fixed Points. It may be used as a blackbody source over t...
Код: 427
Thermo-Paramagnetic Oxygen Analyzer - Michell XTP501
Thermo-Paramagnetic Oxygen Analyzer - Michell XTP501
A lightweight oxygen analyzer or transmitter for cost-effective quality control in safe area applications, such as monitoring oxygen purity. Using Michell’s tried and tested Thermo-Paramagnetic oxygen sensing technology the XTP501 has no co...
Код: XTP501