Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

RBC Resistance Bridge Calibrators

- Temperature Coefficient: < ±0.3 ppm/ °C.

- The problem: Temperature measurement is one of the most demanding applications of resistance measurement. Calibrate thermometry bridges quickly, simply and in-house

- Calibrate ac and dc thermometry bridges

- High accuracy - better than 0.01 ppm at 100 Ohms (RBC100A)

- Patented design licensed from IRL

- Windows application for full analysis and reporting

Brief specifications


More details

Operating principles The problem: Temperature measurement is one of the most demanding applications of resistance measurement. It requires the measurement of resistance ratios to accuracies of 0.1ppm or better. While dc resistance standards are sometimes available at this level, ac resistance standards are generally not. So how can we show our bridges are accurate at this level, and that our resistance and temperature measurements are traceable? The linearity check One simple method for checking a resistance bridge is to measure a pair of resistors separately, and then measure the two in series. Ideally the series measurement should equal the sum of the two individual measurements. If not, then the measurements give us a bit of information about the errors in the bridge readings. Note that we do not need to know the values of the resistors to make this test work. The complement check Another check is to measure the ratio of two resistances, say R1/R2, then swap the resistors and measure the reciprocal ratio (or complement), R2/R1. Ideally the product of the two measurements should equal 1.0 exactly, if not, the measurements give us more information on the bridge errors. Once again, we do not need to know the values of the resistors to make this test work. The combinatorial method The RBC exploits the same principles as the linearity and complement check. It uses a network of four stable four terminal resistors that can be connected in 35 different series and parallel combinations. By measuring each RBC combination in the two different ways (as with the complement check) up to 70 different measurements can be made. Since the RBC has just four unknown resistance values, we have up to 66 independent measurements containing information about the errors in the bridge readings. The combinatorial calibration method is particularly powerful because it is not necessary to know the actual values of the four resistors, or their frequency dependence. This means we can calibrate any ac or dc bridge to any accuracy, so long as the various resistance combinations are accurate. The patented RBC Calibrators are a result of research carried out by Rod White at the Measurement Standards Laboratory of New Zealand, which operates within Industrial Research Ltd (IRL). Isothermal Technology Ltd has an exclusive licence from IRL to develop, sell and produce the RBC. Introducing the RBC


ВимірюванняГенерація (Імітація)


RBC Resistance Bridge Calibrators

- Temperature Coefficient: < ±0.3 ppm/ °C.

- The problem: Temperature measurement is one of the most demanding applications of resistance measurement. Calibrate thermometry bridges quickly, simply and in-house

- Calibrate ac and dc thermometry bridges

- High accuracy - better than 0.01 ppm at 100 Ohms (RBC100A)

- Patented design licensed from IRL

- Windows application for full analysis and reporting

Featured Products

PM620 Pressure Modules
PM620 Pressure Modules
The PM620 series is the latest development in digital output sensor technology incorporating a number of key innovations to allow pressure re-ranging of compatible equipment. A simple screw fit makes both the pressure and electrical connect...
Код: PM620
Handheld Water Activity Meter - Rotronic HygroPalm HP23-AW
Handheld Water Activity Meter - Rotronic HygroPalm HP23-AW
In many situations it can be very useful to measure water activity at goods-in, production or storage rooms, e.g. inspection of bulk materials to ensure they meet specifications...
Код: HP23-AW
microK Channel Expander
microK Channel Expander
The microsKanner can be used with any member of the microK family to add further channels, up to a maximum of 90 expansion channels. Easy to Use: The use of plug-and-play technology means that the extra channels appear automatically on your...
Код: microK
AII GPR-1500 PPM Oxygen Analyzer/ Transmitter
AII GPR-1500 PPM Oxygen Analyzer/ Transmitter
A wall mounted oxygen analyzer in a NEMA enclosure, suitable for indoor or outdoor. This single channel oxygen monitor is supplied with a stainless steel O2 sensor housing for trace oxygen gas analysis in safe as well as hazardous areas whe...
Код: GPR-1500
Hydrocarbon Dew Point Analyzer - Condumax II Transportable
Hydrocarbon Dew Point Analyzer - Condumax II Transportable
Transportable hydrocarbon dew-point analyzer system for field-measurements in natural gas. Suitable for IEC Zone 1 or 2 hazardous area, NEC Class I, Division 1 Groups B, C, D. A complete transportable natural gas dew-point analysis system ...
Код: Condumax II Trans
PDCR/PMP 4300 Series High-Temp Pressure Transducers
PDCR/PMP 4300 Series High-Temp Pressure Transducers
Success in motorsport depends on hundreds of components working together under extreme conditions, and Baker Hughes continues to develop Druck pressure transducers that give the ultimate performance. Druck motorsport sensors have become a w...
Код: PDCR/PMP
NPL Platinum / Palladium Thermocouple
NPL Platinum / Palladium Thermocouple
These Platinum / Palladium Thermocouples (Pt/Pd) are manufactured by the National Physical Laboratory (NPL) who have developed a novel physical mechanism which mitigates the mechanical stresses caused by the different thermal expansion of P...
4.3333/5 3text_more_review
Код: NPL
Calisto 4953
Calisto 4953
Need advice on which model? Dry Block Selection Guide These models will calibrate temperature probes from -45°C to 250°C with unrivalled flexibility. As a traditional Dry Block, several thermometers can be quickly calibrated. Accessories ar...
Код: 4953
Fast-Cal High
Fast-Cal High
Fast-Cal – the product range you designed During early 2004 20 experienced engineers from many parts of the world were asked to produce their ideal specification for industrial calibration. Their top ten requirements, in order of priority, ...
5.0000/5 1text_less_review
Код: High
PROGRAPH Measurement Analysis Software
Software Designed to be used in conjunction with the 8000 Precision Multimeter Series and 8500 Low Thermal Scanner, ProGraph provides an instant solution for graphing stability, temperature and many other parameters. ProGraph is a 'plug and...
Код: PROGRAPH
Venus 4951
Venus 4951
Multi Function: Six Modes including Dry Block and Liquid Bath Fast Response 35mm x 160mm Calibration Volume Calibrate Whole Measurement Loop Need advice on which model? Dry Block Selection Guide These models will calibrate temperature probe...
Код: 4951
Filters and Filter Carriers for Rotronic HC2A Humidity Probes
Filters and Filter Carriers for Rotronic HC2A Humidity Probes
Filter carriers protect the humidity and temperature sensors and probes against mechanical damage. Filters act as a protective barrier against contaminants/pollutants that can influence the sensor. When choosing the correct combination of f...
Код: HC2A
6634A SERIES
6634A SERIES
GUILDLINE INSTRUMENTS 6634A SERIES is a modular series of Resistance Standards that can be rack mountable or simply set on a bench. The 6634A Series provides a set of up to 10 precision resistance standards enclosed in a temperature control...
Код: 6634A
Medusa R Model 999
Medusa R Model 999
The Medusa R Blackbody Calibration Source allows for calibration of noncontact infrared thermometers over the temperature range 30°C to 550°C. It is suitable for use as a radiation source for infrared thermometers. The cavity is 45 x 285mm ...
Код: 999
AII GPR-2600 Oxygen Analyzer
Our range of oxygen analyzers are designed to monitor gas produced or used in industrial processes where trace oxygen from low parts per million to pure O2 must be precisely measured. Utilizing AII’s high performance galvanic oxygen sensors...
Код: GPR-2600
ADT959A Hydraulic Pressure Test Pump
ADT959A Hydraulic Pressure Test Pump
The new Additel 959A Hydraulic Pressure Test Pump is a benchtop pressure pump designed to generate pressure to 40,000 psi (2,800 bar). This pump incorporates a dual-piston system which is ideal for filling large volume workload with the han...
Код: ADT959A
5030 SERIES
5030 SERIES
GUILDLINE INSTRUMENTS 5030 SERIES are precision air baths providing uniform constant temperature over a range of operating environments. To improve measurements and reduce the uncertainty contribution from temperature effects, these high qu...
Код: 5030
787 Model
787 Model
The Model 787 calibrator redefines industry standards by blending industry leading performance and speed of operation within a robust design tailored for extreme conditions. The maximum operating temperature is 660°C allowing wide range of ...
Код: 786
Humidity Transmitter HVAC - Rotronic HygroFlex HF1
Humidity Transmitter HVAC - Rotronic HygroFlex HF1
The HygroFlex1 series is the latest development in inexpensive HVAC transmitters for relative humidity and temperature. The devices are equipped with the tried-and-tested Rotronic Hygromer® IN-1 sensor and boast unbeatable value for money....
Код: HF1
Differential Pressure Transmitter - Rotronic PF4/5
Differential Pressure Transmitter - Rotronic PF4/5
Measuring and Monitoring differential Pressure in Clean Rooms, Food and Pharma. Choice of two different sensor technologies (thermal measuring method and diaphragm sensor) The new differential pressure transmitters PF4 and PF5 with two dif...
Код: PF4/5