- Continuity resistance standard accuracy 0.2Ω - 1kΩ 1% (0.25% Option)

- Continuity current 0 - 320mA 1.3%

- Insulation test voltage measurement 0Ω - 2GΩ 0.3% (0.1% Option)

- AC voltage output 100V - 400V 0.2%

- Loop resistance 3mA - 3A 1.2%

- PAT earth bond resistance 0.05Ω - 1kΩ 0.5%

- PAT earth bond current measurement 100mA - 30A 1.5%

- PAT insulation resistance 0Ω - 2GΩ 0.3% (0.1% Option)

- PAT leakage current 2mA - 7.7mA 1.5%

- PAT leakage test voltage 100V - 300V 1.5%

Brief specifications


More details

The industry leading 3200B series provides by far the fastest and safest solution for calibration of Loop, RCD, PAT's and insulation testers. By using the 3200B series, calibration time can be drastically reduced, while superior accuracy means that cost-effective calibration can be put easily in to practice, ensuring a fast return on investment. FAST, EFFICIENT AND SAFE ELECTRICAL TEST EQUIPMENT CALIBRATION The industry leading 3200B series provides by far the fastest and safest solution for calibration of Loop, RCD, PAT's and insulation testers. Traditional testing practices require many pieces of test equipment and exposure to hazardous voltages, with a typical multifunction tester taking up to 45 minutes to test. Using the 3200B, calibration time can be dramatically reduced to under 15 minutes, all while increasing safety. Cost effective calibration can be put into practice easily, providing a fast return on investment. pat testing calibration electrical calibration equipment A dedicated localized mains socket on the front panel provides direct connect for Loop and RCD testers, removing the need to make connections to the mains/line voltage using 4mm type test leads and crocodile clips. This important safety feature eliminates the risk of shock to the engineer as connections are made with standard mains/line plugs. SUPERIOR ACCURACY Electric tester tools are continually improving, adding ranges, functions and getting ever more accurate. The 3200B/9200B provides suitable accuracy for calibration of even the most accurate electricians test tools whilst remaining competitively priced and easy to use. The 3200B/9200B achieve a test uncertainty ratio (TUR) of 4:1 when calibrating electricians test tools to provide confidence whilst calibrating. 17th edition test equipment electric tester PORTABILITY The 3200B and 9200B have been designed to have short warm up times for the ultimate in portability. The 3200B/9200B can be up and testing in less than 20 minutes, and are light enough to be carried everywhere.


ВимірюванняГенерація (Імітація)


9200B PORTABLE electrical tesr equipment calibrator

- Continuity resistance standard accuracy 0.2Ω - 1kΩ 1% (0.25% Option)

- Continuity current 0 - 320mA 1.3%

- Insulation test voltage measurement 0Ω - 2GΩ 0.3% (0.1% Option)

- AC voltage output 100V - 400V 0.2%

- Loop resistance 3mA - 3A 1.2%

- PAT earth bond resistance 0.05Ω - 1kΩ 0.5%

- PAT earth bond current measurement 100mA - 30A 1.5%

- PAT insulation resistance 0Ω - 2GΩ 0.3% (0.1% Option)

- PAT leakage current 2mA - 7.7mA 1.5%

- PAT leakage test voltage 100V - 300V 1.5%

Featured Products

Greybody Source Model 975
Greybody Source Model 975
When the high accuracy of the Gemini R is not necessary this product offers a cost effective solution for the calibration and testing of infrared thermometers. The Greybody Model 975 gives fast accurate results with a larger sensing area. A...
Код: 975
4Sight2 Calibration Software
4Sight2 Calibration Software
4Sight2 Calibration software is a web-based calibration management tool that helps you maintain and control your calibration environment to the highest metrology standards. 4Sight2 from Druck, a Baker Hughes business, offers easy-to-use, co...
Код: 4Sight2
Additel 878 Reference Dry Well Calibrator
Additel 878 Reference Dry Well Calibrator
Additel takes temperature calibration to the next level with the ADT878 reference dry block calibrators. If you're looking for the best dry-block calibrator on the market, you've found it! Additel's commitment to continuous improvement, qua...
Код: ADT878-700
PRTCalc
PRTCalc
PRTCalc is a free utility for those involved with PT100 platinum resistance thermometers. It allows for the accurate conversion of resistance to temperature or temperature to resistance. PRTCalc conforms with IEC 751 Amendment 2: December 1...
Код: PRTCalc
Cryostat Model 459
Cryostat Model 459
When we considered low temperature comparison calibration, we had to take into account Health and Safety considerations, both of the liquids used in compressors to generate low temperatures and also the liquids used in the calibration volum...
4.6667/5 3text_more_review
Код: 460
Meteorology RH and T Probes - Rotronic MP100A/MP400A
The MP100A is a combined humidity and temperature probe designed primarily for meteorological and general outdoor applications. Operation from DC voltage and low power consumption make the MP101A particularly suitable for operation at remot...
Код: MP100A/MP400A
P3000 Pneumatic Deadweight Testers
P3000 Pneumatic Deadweight Testers
The P3000 Series is the culmination of over 50 years of experience in the production and design of high performance pressure standards. With features designed to improve accuracy and performance, increase reliability and simplify operation ...
Код: P3000
Large Volume Liquid Bath Model 820
Large Volume Liquid Bath Model 820
If you have a large number of sensors to calibrate then this economically priced stirred liquid bath is the solution. The 820 bath has been introduced to provide a liquid calibration bath with a large volume. This is to allow the bath to be...
5.0000/5 1text_less_review
Код: 820
IO620-BSP  A set of test point adaptors
IO620-BSP  A set of test point adaptors
A set of test point adaptors to connect the tool less quick fit PV62XG, MC620G and the extension hoses to the device under test...
Код: IO620-BSP
ADTS552F Air data test system
ADTS552F Air data test system
The ADTS552F air data test set is a portable two-channel flightline pitot static tester with large pitot static volume capability for use on a wide range of aircraft, from light aircraft to wide body passenger and freight aircraft. It provi...
Код: ADTS552F
7330 Series of Oil Based Resistance Standards
7330 Series of Oil Based Resistance Standards
Guildline Instruments 7330 Series of Oil Based Resistance Standards are designed for high accuracy resistance calibration in oil (Fluid Baths) or in air. PRODUCT FEATURES Typical AC/DC Error ...
Код: 7330
ADTS542F Air data test system
ADTS542F Air data test system
The ADTS542F air data test set is a small, lightweight and cost-effective portable two-channel flightline pitot static tester for ‘Aircraft on the Ramp’ testing. The ADTS542F is also ideal for any aircraft with low pitot static volume deman...
Код: ADTS542F
Binary Gas Analyzer for Hydrogen Monitoring - Michell XTC601
Binary Gas Analyzer for Hydrogen Monitoring - Michell XTC601
A robust, linear and stable thermal conductivity analyzer for measurement of binary gas mixes such as air in hydrogen, nitrogen, argon, helium or carbon-dioxide. The sensor is housed in a rugged casing, making it suitable for a wide range o...
Код: XTC601
ATEX Humidity and Temperature Transmitter - Rotronic HF5-EX
ATEX Humidity and Temperature Transmitter - Rotronic HF5-EX
The Rotronic HygroFlex5-EX series consists of two-channel transmitters for the exact measurement of humidity and temperature in explosive atmospheres. This device conforms to the latest international standards. The robust aluminium HF5-EX h...
Код: HF5-EX
9336 SERIES OF PRECISION RESISTANCE STANDARDS
9336 SERIES OF PRECISION RESISTANCE STANDARDS
THE 9336 OR 9337 SERIES OF PRECISION RESISTANCE STANDARDS ARE EXCELLENT SOLUTIONS AS HIGH TO ULTRA HIGH LABORATORY RESISTANCE STANDARDS OR FOR PORTABLE APPLICATIONS REQUIRING HIGH ACCURACY WITH RESISTANCE VALUES FROM 10 MΩ TO 10 PΩ. PRODUCT...
Код: 9336
Hydra Model 798H
Hydra Model 798H
Precision calibration of thermometers calls for the use of stirred liquid calibration baths. The Hydra models set new standards in terms of price to performance ratio. Now Calibration Engineers and Metrologists can choose from a range of ba...
Код: 798H
6622T Temperature Bridge Series
6622T Temperature Bridge Series
The 6622T Temperature Bridge Series expands upon the success of 6622A Series Resistance Bridges by utilizing new design features to offer leading uncertainties and stabilities for Temperature Bridges. The 6622T Operating Range is from 0.1 Ω...
Код: 6622T
Simple Nitrogen Boiling Point Apparatus Model 461
Simple Nitrogen Boiling Point Apparatus Model 461
This model is a lower cost alternative to the ITL M 18205. This model is a simple apparatus open to the atmosphere comprising a stainless steel dewar flask filled with liquid Nitrogen, an insulating layer which houses a metallic equalising ...
Код: 461
IO620-USB-PC USB cable
USB cable Connects the DPI620G or DPI620G-IS to a PC...
Код: IO620-USB-PC