Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

AII GPR-7100 Portable PPM H2S Analyzer

-Accuracy: < 2% of FS range under constant conditions

Analysis: 0-20, 0-50, 0-100 PPM FS ranges; auto-ranging or manually lock on single range

Application: Trace PPM H2S in flowing gas streams

Area Classification: Meets intrinsic safety standards for use in Class 1, Division 1, Group C, D hazardous areas

Flow Sensitivity: Maintain constant flow; air 1 SCFH, sample 1 SCFH

Pressure: Inlet - regulate to 5-30 psig to deliver constant 1 SCFH sample flow rate; vent – atmospheric

Power: Rechargeable battery, 8 hours day duty cycle

Sample System: Coalescing filter and flow meters; Air to sample gas flow ratio 1:1 SCFH

Sensor Model: OSV-72-7HH (standard ranges)

Temp. Range: -10 ºC to 45 ºC

  • AII GPR-7100 Portable PPM H2S Analyzer
Brief specifications


More details

The GPR-7500 analyzer utilizes the low-power electro-chemical sensor technology to provide a cost-effective and easy to maintain online-installation hydrogen sulfide measurement in a small package. The GPR-7100 is a portable H2S analyzer version preferably used for spot checking the process or temporary usage during servicing or commissioning of a permanent installation gas analyzer. These advanced instruments from AII are agency approved for use in flammable gas streams.


ВимірюванняГенерація (Імітація)


AII GPR-7100 Portable PPM H2S Analyzer

-Accuracy: < 2% of FS range under constant conditions

Analysis: 0-20, 0-50, 0-100 PPM FS ranges; auto-ranging or manually lock on single range

Application: Trace PPM H2S in flowing gas streams

Area Classification: Meets intrinsic safety standards for use in Class 1, Division 1, Group C, D hazardous areas

Flow Sensitivity: Maintain constant flow; air 1 SCFH, sample 1 SCFH

Pressure: Inlet - regulate to 5-30 psig to deliver constant 1 SCFH sample flow rate; vent – atmospheric

Power: Rechargeable battery, 8 hours day duty cycle

Sample System: Coalescing filter and flow meters; Air to sample gas flow ratio 1:1 SCFH

Sensor Model: OSV-72-7HH (standard ranges)

Temp. Range: -10 ºC to 45 ºC

Featured Products

ADTS542F Air data test system
ADTS542F Air data test system
The ADTS542F air data test set is a small, lightweight and cost-effective portable two-channel flightline pitot static tester for ‘Aircraft on the Ramp’ testing. The ADTS542F is also ideal for any aircraft with low pitot static volume deman...
Код: ADTS542F
HygroSmart HS3 Relative Humidity and Temperature Probe
HygroSmart HS3 Relative Humidity and Temperature Probe
The HygroSmart HS3 an advanced, digital probe with measured or calculated outputs and a rugged 10 bar pressure rated housing, designed to provide reliable humidity measurement for process control in a wide range of applications. The HS3 pro...
Код: HS3
Differential Pressure Transmitter - Rotronic PF4/5
Differential Pressure Transmitter - Rotronic PF4/5
Measuring and Monitoring differential Pressure in Clean Rooms, Food and Pharma. Choice of two different sensor technologies (thermal measuring method and diaphragm sensor) The new differential pressure transmitters PF4 and PF5 with two dif...
Код: PF4/5
6564 High to Ultra-High Resistance Scanners
6564 High to Ultra-High Resistance Scanners
Guildline’s 6564 High to Ultra-High Resistance Scanners are the first commercial scanners capable of operating with measurement capabilities to 10 PΩ’s and at voltages to 1000 Vdc. This capability greatly improves the measurement and calibr...
Код: 6564
Hydra Model 798L
Hydra Model 798L
Precision calibration of thermometers calls for the use of stirred liquid calibration baths. The Hydra models set new standards in terms of price to performance ratio. Now Calibration Engineers and Metrologists can choose from a range of ba...
Код: 798L
Fast-Cal High
Fast-Cal High
Fast-Cal – the product range you designed During early 2004 20 experienced engineers from many parts of the world were asked to produce their ideal specification for industrial calibration. Their top ten requirements, in order of priority, ...
5.0000/5 1text_less_review
Код: High
precis.io
precis.io
Application works as Control Software for products of Applied Precision. It can show measured values, control meter error measurement and generation of signals (in PTE device)...
Код: precis
Humidity Temperature Probes - Rotronic HC2A-S/S3/SM
The HC2A series are digital humidity-temperature probes based on the AirChip3000 technology. These probes feature a UART serial interface and two 0…1 V linear analog output signals. The HC2A probes are designed for use with the HygroClip2...
Код: HC2A-S/S3/SM
DPI610E Hand-held pressure calibrator
DPI610E Hand-held pressure calibrator
The DPI610E combines effortless pressure measurement and generation, signal measurement and loop power with significantly improved pump capabilities and a powerful touch and button user interface. With a robust design, the unit has been ...
Код: DPI610E
POTTS – Oceanus-6 Model 580
POTTS – Oceanus-6 Model 580
The multi-functions of the Oceanus-6 is a unique concept from Isotech, so unique that it is currently the subject of a patent application. The Oceanus-6 is a complete calibration laboratory working over the temperature range 45°C below ambi...
Код: 580
IO620-AC AC voltage measurement probe
IO620-AC AC voltage measurement probe
Replacement AC voltage measurement probe Attaches to the DPI620G, 30 V sockets to provide 300 VAC true rms measurement...
Код: IO620-AC
9211B PRECISION MULTI-TAP CURRENT SHUNT
9211B PRECISION MULTI-TAP CURRENT SHUNT
GUILDLINE INSTRUMENTS 9211B PRECISION MULTI-TAP CURRENT SHUNT is an improved version of the world's most widely fielded multi-tap shunt available, the model 9211A. PRODUCT FEATURES Accuracies as Low as ± 0.01 % Now with New Style Case with ...
Код: 9211B
AII GPR-3500 MO Portable Oxygen PurityAnalyzer
The GPR-3500MO is supplied with panel mounted flow meter for maximum portability...
Код: GPR-3500
Additel 875-1210 Thermocouple Calibration Furnaces
Additel 875-1210 Thermocouple Calibration Furnaces
We understand the many challenges associated with thermocouple calibration work. That is precisely why we decided to introduce the ADT875-1210 and ADT878-1210 Thermocouple Calibration Furnaces. With an unmatched stability, uniformity and an...
Код: ADT878-1210
6664C LOW THERMAL QUAD CHANNEL SCANNERS
6664C LOW THERMAL QUAD CHANNEL SCANNERS
THE 6664C LOW THERMAL QUAD CHANNEL SCANNERS ENABLES SOFTWARE CONTROLLED, FULLY AUTOMATED NORMAL AND HIGH OHM MEASUREMENTS WITH VOLTAGES UP TO 1000 V PRODUCT FEATURES Withstands up to 1000 Vdc to provide fully automated resistance measuremen...
Код: 6664C
microK Precision Thermometry Bridge
microK Precision Thermometry Bridge
The microK 70 and 125 models are designed for the Primary Temperature Laboratories whilst the microK 250 and 500 models were designed for the Secondary Laboratory as well as a wide range of high accuracy industrial and scientific calibratio...
3.0000/5 4text_more_review
Код: croK
Simple Nitrogen Boiling Point Apparatus Model 461
Simple Nitrogen Boiling Point Apparatus Model 461
This model is a lower cost alternative to the ITL M 18205. This model is a simple apparatus open to the atmosphere comprising a stainless steel dewar flask filled with liquid Nitrogen, an insulating layer which houses a metallic equalising ...
Код: 461
Michell Condumax II and OptiPEAK TDL600 Dew-Point Analyzer
Michell Condumax II and OptiPEAK TDL600 Dew-Point Analyzer
Hydrocarbon dew point (HCDP) and moisture are key quality parameters to ensure the quality of pipeline transmission gas. With the combined Condumax II and OptiPEAK TDL600 analyzer system pipeline operators have the assurance of the most wid...
Код: TDL600 Dew-Point
Jupiter 4852
Jupiter 4852
Need advice on which model? Dry Block Selection Guide The Jupiter Dry Block range offers industry-leading performance in an easy to use portable package – ideal for the calibration of thermocouples and platinum resistance thermometers. It h...
5.0000/5 1text_less_review
Код: 4852
Gallium Fixed Point Apparatus
Gallium Fixed Point Apparatus
Model 17402B Gallium Apparatus is not an adaptation from general purpose equipment, but is designed specifically to realize and maintain the Gallium Cell on the melt plateau, for calibration of thermometers on the International Temperature ...
Код:
Спасибо!