Blackbody Source Model 989

- Covers 20°C to 50°C with Fast Thermal Response

- Model 989 has the same performance as the earlier 988 but is smaller and has two easy mounting points fitted allowing for easy mounting. When used in conjunction with IR cameras the device can easily be suspended from above or below using standard tripod mounting brackets.

- Improves accuracy of Fever Detection Systems

- Check Non-Contact Thermometers

- Uses a solid state thermoelectric heat pump so that the block can be both cooled and heated

Brief specifications


More details

Isotech first introduced the Model 988 to assist in relation to the SARS outbreak during the early 2000s. Used to increase the accuracy of thermal imagers being used to measure human skin temperature in temperature screening of applications. It can also be used to check non-contact clinical thermometers. Following the increased demand in relation to COVID-19, Isotech have now introduced an updated blackbody source, Model 989. Model 989 has the same performance as the earlier 988 but is smaller and has two easy mounting points fitted allowing for ease of use. When used in conjunction with IR cameras, the device can easily be suspended from above or below using standard tripod mounting brackets. The upgraded controller that is used can either be locked to a single temperature or it can be adjusted over a new wider temperature range of 20°C to 50°C. Model 989 also has a PC interface fitted as standard that allows the temperature to be both monitored and adjusted from a PC. This Model 989 blackbody source meets the demand for a simple, cost effective but high accuracy device for the calibration of thermal imagers and infrared thermometers that are used at temperatures around that of the human body. Unlike heat only devices, this model uses a solid state thermoelectric heat pump so that the block can be both cooled and heated. This brings two benefits, the blackbody can maintain its set point in high ambient temperature conditions and it can also operate below the ambient temperature. Response time is very fast, typically less than five minutes to achieve the required temperature (see graphs). The Model 989 can be used either horizontally or vertically. The device features a high emissivity ridged plate that is 70mm in diameter. The temperature of the plate can be set from 20°C to 50°C to a resolution of 0.01°C. To reduce sensitivity to air draughts and ambient temperature effects, a stainless steel tube can be fitted in front of the plate with evaluation showing this has advantages over an open plate design. The longer tube length is 210mm while the shorter tube is 40mm long and is particularly useful for checking medical thermometers. For applications where the unit is used at a single fixed temperature, e.g. 38°C, the set temperature on the controller can be locked to prevent accidental change or tampering. The operating unit can be changed from Celsius to Fahrenheit.


ВимірюванняГенерація (Імітація)


Blackbody Source Model 989

- Covers 20°C to 50°C with Fast Thermal Response

- Model 989 has the same performance as the earlier 988 but is smaller and has two easy mounting points fitted allowing for easy mounting. When used in conjunction with IR cameras the device can easily be suspended from above or below using standard tripod mounting brackets.

- Improves accuracy of Fever Detection Systems

- Check Non-Contact Thermometers

- Uses a solid state thermoelectric heat pump so that the block can be both cooled and heated

Featured Products

Icarus
Icarus
Download Icarus – Evaluation Download Icarus Data Sheet Download Software Guide Icarus is designed to calculate and display the relationship between resistance and temperature for Standard Platinum Resistance Thermometers between the triple...
Код:
AC Shunt Accessories
Complete Selection of Measurement Accessories for the 7340 and 7350 Series of AC Shunts. AVAILABLE PRODUCTS AND FEATURES Forced Air Convection Unit provides excellent heat dissipation and a more stable output AC Buffer Amplifier for low cur...
Код: AC
Additel 875-1210 Thermocouple Calibration Furnaces
Additel 875-1210 Thermocouple Calibration Furnaces
We understand the many challenges associated with thermocouple calibration work. That is precisely why we decided to introduce the ADT875-1210 and ADT878-1210 Thermocouple Calibration Furnaces. With an unmatched stability, uniformity and an...
Код: ADT875-1210
Dew-Point Calibration System - Michell DCS
Dew-Point Calibration System - Michell DCS
The DCS system is a complete rack-mounted calibration station capable of producing a flow of air (or nitrogen) at a pre-specified range of dew-point temperatures from a minimum of -100°C (-148°F) to a maximum of +20°C (+68°F). Through custo...
Код: DCS
AII GPR-18
The GPR-1800 series of intrinsically safe trace oxygen analyzers are designed for use in demanding process environments where the low detection limit down the AII’s industrial oxygen sensors can be well utilized. Typical for Analytical Indu...
Код: GPR-18
Gallium Fixed Point Cell
Gallium Fixed Point Cell
Second only to the Water Triple Point and in many ways, because of its ease of use and purity, superior to it, is the Gallium Melt Point. At 29.7646°C this is a very convenient temperature. Total Confidence Confidence is a major requirement...
Код: Gallium
Venus 4951
Venus 4951
Multi Function: Six Modes including Dry Block and Liquid Bath Fast Response 35mm x 160mm Calibration Volume Calibrate Whole Measurement Loop Need advice on which model? Dry Block Selection Guide These models will calibrate temperature probe...
Код: 4951
PG9602/9607 Piston Gauge
PG9602/9607 Piston Gauge
The PG9607 is the next generation of absolute pressure piston gauge from Fluke Calibration. It supports the use of a 100 kg mass set to define gauge and absolute pressures from 11 to 500 kPa with a single piston-cylinder. The PG9602 is the ...
Код: PG9602/9607
IO620-HOSE-H1-IS High pressure hydraulic hose in hazardous area use
A high pressure hydraulic hose rated to 1,000 bar (15,000 psi) and terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. The hose is self sealing to avoid leakage...
Код: IO620-HOSE-H1-IS
ADTS552F Air data test system
ADTS552F Air data test system
The ADTS552F air data test set is a portable two-channel flightline pitot static tester with large pitot static volume capability for use on a wide range of aircraft, from light aircraft to wide body passenger and freight aircraft. It provi...
Код: ADTS552F
Diagnostic Communication Tool for Michell Easidew and Pura
A comprehensive and self-contained tool to make routine service and maintenance of the Easidew and Pura ranges of dew-point transmitters simple to carry out. The Universal Communications Kit comprises: Electronic communications platform ...
Код: Tool
Precision Chilled Mirror Hygrometer - Michell S8000
Precision Chilled Mirror Hygrometer - Michell S8000
The S8000 precision hygrometer provides a direct measurement of dew point, temperature and pressure. Suitable for both industrial and laboratory applications, the instrument is compact and self-contained. Dew-point measurement is based on ...
Код: S8000
Oxygen Analyzer for Gas Purity Measurements - Michell XZR400
Oxygen Analyzer for Gas Purity Measurements - Michell XZR400
The XZR400 zirconium oxide gas purity analyzer from Michell Instruments is designed to measure oxygen as an impurity in inert gases such as nitrogen, carbon dioxide, helium and argon. A range of trace oxygen analyzers utilizing Michell's M...
Код: XZR400
6640Q QUANTUM HALL RESISTANCE (QHR) BRIDGE
6640Q QUANTUM HALL RESISTANCE (QHR) BRIDGE
GUILDLINE INSTRUMENTS 6640Q QUANTUM HALL RESISTANCE (QHR) BRIDGE has been completely redesigned to provide better uncertainties and more operational capability. PRODUCT FEATURES New Patented Toroid Design New Dual Processor Design New Dedic...
Код: 6640Q
ADT793 Pressure Controller & Generator
ADT793 Pressure Controller & Generator
The Additel 793 pressure controller combines the latest control/measure technology, modular design and easy to use/maintenance features into a single users friendly device. The Additel 793 provides pressure control up to 15,000 psi (1,000 B...
Код: ADT793
Large Volume Liquid Bath Model 820
Large Volume Liquid Bath Model 820
If you have a large number of sensors to calibrate then this economically priced stirred liquid bath is the solution. The 820 bath has been introduced to provide a liquid calibration bath with a large volume. This is to allow the bath to be...
5.0000/5 1text_less_review
Код: 820
Hydrocarbon Dew-Point Analyzer - Michell Condumax II
Hydrocarbon Dew-Point Analyzer - Michell Condumax II
The Condumax II hydrocarbon and water dew-point analyzer provides continuous, automatic measurements of these two critical parameters of natural gas quality. It uses the ‘Dark Spot’ direct chilled-mirror technique to measure hydrocarbon dew...
Код: Condumax II
Benchtop Water Activity Meter - Rotronic HygroLab
Benchtop Water Activity Meter - Rotronic HygroLab
The Rotronic HygroLab is an innovative high-end laboratory analyzer for water activity measurements with up to four measurement probe inputs. Simultaneous or asynchronous measurement with the tried-and-tested AW Quick measuring function for...
Код: HygroLab
Gallium Fixed Point Apparatus
Gallium Fixed Point Apparatus
Model 17402B Gallium Apparatus is not an adaptation from general purpose equipment, but is designed specifically to realize and maintain the Gallium Cell on the melt plateau, for calibration of thermometers on the International Temperature ...
Код:
Michell XTC501 Thermal Conductivity Analyser
Michell XTC501 Thermal Conductivity Analyser
A lightweight and compact binary gas analyzer for measuring gas mixtures – such as air in argon or carbon dioxide in air. Suitable for installation in safe areas the XTC501 has a tough, IP55-rated housing. Available with an optional display...