Categories
-
Pressure
-
Temperature
-
Humidity
-
Electrical signals
- Calibrator of electrical signals
- Reference multimeters
- Voltage, resistance, frequency standards
- Precision bridges
- Teraohmmeter
- Reference electricity meters
- Installations for verification of electricity meters
- Power analyzers
- Voltage dividers
- Current shunts
- Precision current transformers
- Systems for measuring current
- Precision measuring systems
- Test Equipment
- Liquid and air baths for resistance measures
- Standards of conductivity (salinity)
- Software
- Accessories
- Multifunction calibrators
-
Flow measurement
-
Chemical composition
-
Complex solutions
-
Services
4010 advanced multiproduct calibrator
- DC voltage 0 - ± 1025 V (± 8 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 1 MHz (0.015%)
- AC current 20 μA - 30 A, 10 Hz - 30 kHz (0.04%)
- Resistance (passive) 0 Ohm - 1 GOhm (18 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (1 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Resistance (simulation) 0 ohm - 1 GOhm (100 ppm)
4015 advanced multiproduct calibrator
- DC voltage 0 - ± 1025 V (± 15 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 500 KHz (0.015%)
- AC current 20 μA - 30 A, 10 Hz - 30 kHz (0.04%)
- Resistance (passive) 0 Ohm - 1 GOhm (40 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Resistance (simulation) 0 ohm - 1 GOhm (100 ppm)
4610M ADVANCED MULTIPRODUCT CALIBRATOR
AC & DC Voltage to 1000V
AC & DC Current to 30A
2/4 wire Decade and Variable Resistance to 1G
Decade and Variable Capacitance to 100mF
Frequency to 1MHz
Thermocouple Source & Measure
GPIB (IEEE-488) & USB interface standard
7″ full color touch screen
0 - 1000V DC
1mV - 1000V AC, 10Hz to 1MHz
Variable Resistance 0 Ohms to 1GOhms
Variable Capacitance 1nF to 100mF
10Hz to 1MHz Frequency Output
3010A precision multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 8 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 1 MHz (0.015%)
- AC current 20 μA - 30 A, 10 Hz - 10 kHz (0.04%)
- Resistance (passive) 0 Ohm - 1 GOhm (18 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm / 1 ppm optional)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
3041A precision multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 25 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 500 KHz (0.04%)
- AC current 20 μA - 30 A, 10 Hz - 10 kHz (0.06%)
- Resistance (passive) 0 Ohm - 1 GOhm (40 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm / 1 ppm optional)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
3050A precision multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 50 ppm)
- DC current 0 - ± 22 A (± 100 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 100 KHz
- AC current 20 μA - 22 A, 10 Hz - 10 kHz (0.07%)
- Resistance (passive) 0 Ohm - 100 MΩ (60 ppm)
- Capacitance (passive) 10 nF - 1 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
1000A PORTABLE ultra portable calibrator
- DC voltage 0 - ± 1000 V (± 80 ppm)
- DC current 0 - ± 10A (± 0.05%)
- AC voltage 0 - ± 1000 V (± 0.08%)
- AC current 0 - ± 10 A (± 0.1%)
- Resistance (passive) 0 Ohm - ± 100 MΩ (± 0.02%)
- Capacitance (passive) 10 nF - 1 μF (0.8%)
- Frequency 1 Hz - 100 KHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.22 ° C)
- Weight 9.2 kg
- Dimensions 257 * 432 * 180 mm (H, W, D)
1000B BENCHTOP ultra portable calibrator
- DC voltage 0 - ± 1000 V (± 80 ppm)
- DC current 0 - ± 10A (± 0.05%)
- AC voltage 0 - ± 1000 V (± 0.08%)
- AC current 0 - ± 10 A (± 0.1%)
- Resistance (passive) 0 Ohm - ± 100 MΩ (± 0.02%)
- Capacitance (passive) 10 nF - 1 μF (0.8%)
- Frequency 1 Hz - 100 KHz (20ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.22 ° C)
- Weight 9.5 kg
- Dimensions 180 * 447 * 297 mm (H, W, D)
9041A transportable multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 50 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 500 KHz (0.04%)
- AC current 20 μA - 30 A, 10 Hz - 10 kHz (0.06%)
- Resistance (passive) 0 Ohm - 1 GOhm (40 ppm)
- Capacitance (passive) 10 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm / 1 ppm optional)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Dry block temperature (optional) 25 ° C- 200 ° C (1 ° C)
- Blackbody temperature source (optional) 25 ° C- 200 ° C (1 ° C)
9050A transportable multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 50 ppm)
- DC current 0 - ± 22 A (± 100 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 100 KHz
- AC current 20 μA - 22 A, 10 Hz - 10 kHz (0.07%)
- Resistance (passive) 0 Ohm - 100 MΩ (60 ppm)
- Capacitance (passive) 10 nF - 1 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Dry block temperature (optional) 25 ° C- 200 ° C (1 ° C)
- Blackbody temperature source (optional) 25 ° C- 200 ° C (1 ° C)
3200B BENCHTOP electrical test equipment calibrator
- Continuity resistance standard accuracy 0.2Ω - 1kΩ 1% (0.25% Option)
- Continuity current 0 - 320mA 1.3%
- Insulation test voltage measurement 0Ω - 2GΩ 0.3% (0.1% Option)
- AC voltage output 100V - 400V 0.2%
- Loop resistance 3mA - 3A 1.2%
- PAT earth bond resistance 0.05Ω - 1kΩ 0.5%
- PAT earth bond current measurement 100mA - 30A 1.5%
- PAT insulation resistance 0Ω - 2GΩ 0.3% (0.1% Option)
- PAT leakage current 2mA - 7.7mA 1.5%
- PAT leakage test voltage 100V - 300V 1.5%
9200B PORTABLE electrical tesr equipment calibrator
- Continuity resistance standard accuracy 0.2Ω - 1kΩ 1% (0.25% Option)
- Continuity current 0 - 320mA 1.3%
- Insulation test voltage measurement 0Ω - 2GΩ 0.3% (0.1% Option)
- AC voltage output 100V - 400V 0.2%
- Loop resistance 3mA - 3A 1.2%
- PAT earth bond resistance 0.05Ω - 1kΩ 0.5%
- PAT earth bond current measurement 100mA - 30A 1.5%
- PAT insulation resistance 0Ω - 2GΩ 0.3% (0.1% Option)
- PAT leakage current 2mA - 7.7mA 1.5%
- PAT leakage test voltage 100V - 300V 1.5%
3310A precision multiproduct calibrator
- DC voltage 0 - ± 20 V (0 - ± 1000 V optional) (± 8 ppm)
- DC current (optional) 0 - ± 30 A (± 50 ppm)
- AC voltage (optional) 20 mV - 1000 V, 10 Hz -1 MHz (0.015%)
- AC current (optional) 20 μA - 30A, 10 Hz - 10 kHz (0.04%)
- Resistance (passive) (optional) 0 ohm - 1 GOhm (18 ppm)
- Capacitance (passive) (optional) 1 nF - 1 μF (0.25%)
3341A precision multiproduct calibrator
- DC voltage 0 - ± 20 V (0 - ± 1000 V optional) (± 25 ppm)
- DC current (optional) 0 - ± 30 A (± 50 ppm)
- AC voltage (optional) 20 mV - 1000 V, 10 Hz - 500 KHz (0.04%)
- AC current (optional) 20 μA - 30A, 10 Hz - 10 kHz (0.06%)
- Resistance (passive) (optional) 0 ohm - 1 GOhm (40 ppm)
- Capacitance (passive) (optional) 1 nF - 10 μF (0.25%)
3350A precision multiproduct calibrator
- DC voltage 0 - ± 20 V (0 - ± 1000 V optional) (± 50 ppm)
- DC current (optional) 0 - ± 22 A (± 100 ppm)
- AC voltage (optional) 20 mV - 1000 V, 10 Hz - 100 kHz
- AC current (optional) 20 μA - 22A, 10 Hz - 10 kHz (0.07%)
- Resistance (passive) (optional) 0 Ohm - 100 MΩ (60 ppm)
- Capacitance (passive) (optional) 10 nF - 1 μF (0.25%)

-350x280.jpg)
-350x280.jpg)





-350x280.jpeg)