4010 advanced multiproduct calibrator
- DC voltage 0 - ± 1025 V (± 8 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 1 MHz (0.015%)
- AC current 20 μA - 30 A, 10 Hz - 30 kHz (0.04%)
- Resistance (passive) 0 Ohm - 1 GOhm (18 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (1 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Resistance (simulation) 0 ohm - 1 GOhm (100 ppm)
- DC voltage 0 - ± 1025V (± 4 ppm)
- DC current 0 - ± 30 A (± 7 ppm)
- DC current (electrometer input) 10 nA - ± 10 μA Ranges, 0.01 pA Resolution
- AC voltage 20 mV - 1025 V, 10 Hz -1 MHz (0.015%)
- AC current 0 A - 30A (0.03%)
- Resistance 0 Ohm - 1 GOhm (± 8 ppm)
- Resistance (electrometer) 10 mΩ - 1 TΩ, 10 V - 300 V (± 140 ppm)
- Frequency 10 Hz - 1 mHZ (± 5ppm)
- Temperature (PRT / RTD) 2.3 b 4 wires
- Temperature (thermocouple) support up to 8 thermocouples
- Rear Panel Terminals: Standard
4015 advanced multiproduct calibrator
- DC voltage 0 - ± 1025 V (± 15 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 500 KHz (0.015%)
- AC current 20 μA - 30 A, 10 Hz - 30 kHz (0.04%)
- Resistance (passive) 0 Ohm - 1 GOhm (40 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Resistance (simulation) 0 ohm - 1 GOhm (100 ppm)
- DC voltage 0 - ± 1025V (± 9 ppm)
- DC current 0 - ± 30 A (± 25 ppm)
- AC voltage 20 mV - 1025 V, 10 Hz -100 kHz (± 0.05%)
- AC current 0 A - 30A (± 0.08%)
- Resistance 0 Ohm - 1 GOhm (± 20 ppm)
- Frequency 10 Hz - 1 mHZ (± 5ppm)
4610M ADVANCED MULTIPRODUCT CALIBRATOR
AC & DC Voltage to 1000V
AC & DC Current to 30A
2/4 wire Decade and Variable Resistance to 1G
Decade and Variable Capacitance to 100mF
Frequency to 1MHz
Thermocouple Source & Measure
GPIB (IEEE-488) & USB interface standard
7″ full color touch screen
0 - 1000V DC
1mV - 1000V AC, 10Hz to 1MHz
Variable Resistance 0 Ohms to 1GOhms
Variable Capacitance 1nF to 100mF
10Hz to 1MHz Frequency Output
8158 Advanced Digitising Multimeter advanced multimeter
- DC voltage 0 - 1000 V (8 ppm)
- DC current 100 nA - 1.5 A
- AC voltage 0 - 1000 V
- AC current 100 mA - 1.5A
- Resistance 10 Ohm - 1 GOhm
- Front / Rear Inputs: Standard
3010A precision multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 8 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 1 MHz (0.015%)
- AC current 20 μA - 30 A, 10 Hz - 10 kHz (0.04%)
- Resistance (passive) 0 Ohm - 1 GOhm (18 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm / 1 ppm optional)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
8500 Low Thermal 10 Channel Scanner low thermal scanner
- Internal temperature 5 ° C to 35 ° C: Accuracy ± 0.1 ° C
- Humidity 10 to 90% RH: Accuracy 5%
- Main voltage 200V to 260V AC 50Hz
- Number of channels 10
- Changeover 4-pin changeover Kelvin: 2 Voltage: 2 Current
- Maximum voltage 200V
- Maximum current 1A
- Connection Front panel inputs 4mm terminal low thermal gold on
copper
- Thermal EMF is usually less than 150 nV
- Switching resistance Less than 0.2 ohm
- Latching relay type
- RS232 / USB interface (via adapter)
3041A precision multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 25 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 500 KHz (0.04%)
- AC current 20 μA - 30 A, 10 Hz - 10 kHz (0.06%)
- Resistance (passive) 0 Ohm - 1 GOhm (40 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm / 1 ppm optional)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
3050A precision multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 50 ppm)
- DC current 0 - ± 22 A (± 100 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 100 KHz
- AC current 20 μA - 22 A, 10 Hz - 10 kHz (0.07%)
- Resistance (passive) 0 Ohm - 100 MΩ (60 ppm)
- Capacitance (passive) 10 nF - 1 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
1000A PORTABLE ultra portable calibrator
- DC voltage 0 - ± 1000 V (± 80 ppm)
- DC current 0 - ± 10A (± 0.05%)
- AC voltage 0 - ± 1000 V (± 0.08%)
- AC current 0 - ± 10 A (± 0.1%)
- Resistance (passive) 0 Ohm - ± 100 MΩ (± 0.02%)
- Capacitance (passive) 10 nF - 1 μF (0.8%)
- Frequency 1 Hz - 100 KHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.22 ° C)
- Weight 9.2 kg
- Dimensions 257 * 432 * 180 mm (H, W, D)
1000B BENCHTOP ultra portable calibrator
- DC voltage 0 - ± 1000 V (± 80 ppm)
- DC current 0 - ± 10A (± 0.05%)
- AC voltage 0 - ± 1000 V (± 0.08%)
- AC current 0 - ± 10 A (± 0.1%)
- Resistance (passive) 0 Ohm - ± 100 MΩ (± 0.02%)
- Capacitance (passive) 10 nF - 1 μF (0.8%)
- Frequency 1 Hz - 100 KHz (20ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.22 ° C)
- Weight 9.5 kg
- Dimensions 180 * 447 * 297 mm (H, W, D)
9041A transportable multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 50 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 500 KHz (0.04%)
- AC current 20 μA - 30 A, 10 Hz - 10 kHz (0.06%)
- Resistance (passive) 0 Ohm - 1 GOhm (40 ppm)
- Capacitance (passive) 10 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm / 1 ppm optional)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Dry block temperature (optional) 25 ° C- 200 ° C (1 ° C)
- Blackbody temperature source (optional) 25 ° C- 200 ° C (1 ° C)
9050A transportable multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 50 ppm)
- DC current 0 - ± 22 A (± 100 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 100 KHz
- AC current 20 μA - 22 A, 10 Hz - 10 kHz (0.07%)
- Resistance (passive) 0 Ohm - 100 MΩ (60 ppm)
- Capacitance (passive) 10 nF - 1 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Dry block temperature (optional) 25 ° C- 200 ° C (1 ° C)
- Blackbody temperature source (optional) 25 ° C- 200 ° C (1 ° C)
3200B BENCHTOP electrical test equipment calibrator
- Continuity resistance standard accuracy 0.2Ω - 1kΩ 1% (0.25% Option)
- Continuity current 0 - 320mA 1.3%
- Insulation test voltage measurement 0Ω - 2GΩ 0.3% (0.1% Option)
- AC voltage output 100V - 400V 0.2%
- Loop resistance 3mA - 3A 1.2%
- PAT earth bond resistance 0.05Ω - 1kΩ 0.5%
- PAT earth bond current measurement 100mA - 30A 1.5%
- PAT insulation resistance 0Ω - 2GΩ 0.3% (0.1% Option)
- PAT leakage current 2mA - 7.7mA 1.5%
- PAT leakage test voltage 100V - 300V 1.5%
9200B PORTABLE electrical tesr equipment calibrator
- Continuity resistance standard accuracy 0.2Ω - 1kΩ 1% (0.25% Option)
- Continuity current 0 - 320mA 1.3%
- Insulation test voltage measurement 0Ω - 2GΩ 0.3% (0.1% Option)
- AC voltage output 100V - 400V 0.2%
- Loop resistance 3mA - 3A 1.2%
- PAT earth bond resistance 0.05Ω - 1kΩ 0.5%
- PAT earth bond current measurement 100mA - 30A 1.5%
- PAT insulation resistance 0Ω - 2GΩ 0.3% (0.1% Option)
- PAT leakage current 2mA - 7.7mA 1.5%
- PAT leakage test voltage 100V - 300V 1.5%
3310A precision multiproduct calibrator
- DC voltage 0 - ± 20 V (0 - ± 1000 V optional) (± 8 ppm)
- DC current (optional) 0 - ± 30 A (± 50 ppm)
- AC voltage (optional) 20 mV - 1000 V, 10 Hz -1 MHz (0.015%)
- AC current (optional) 20 μA - 30A, 10 Hz - 10 kHz (0.04%)
- Resistance (passive) (optional) 0 ohm - 1 GOhm (18 ppm)
- Capacitance (passive) (optional) 1 nF - 1 μF (0.25%)
3341A precision multiproduct calibrator
- DC voltage 0 - ± 20 V (0 - ± 1000 V optional) (± 25 ppm)
- DC current (optional) 0 - ± 30 A (± 50 ppm)
- AC voltage (optional) 20 mV - 1000 V, 10 Hz - 500 KHz (0.04%)
- AC current (optional) 20 μA - 30A, 10 Hz - 10 kHz (0.06%)
- Resistance (passive) (optional) 0 ohm - 1 GOhm (40 ppm)
- Capacitance (passive) (optional) 1 nF - 10 μF (0.25%)
3350A precision multiproduct calibrator
- DC voltage 0 - ± 20 V (0 - ± 1000 V optional) (± 50 ppm)
- DC current (optional) 0 - ± 22 A (± 100 ppm)
- AC voltage (optional) 20 mV - 1000 V, 10 Hz - 100 kHz
- AC current (optional) 20 μA - 22A, 10 Hz - 10 kHz (0.07%)
- Resistance (passive) (optional) 0 Ohm - 100 MΩ (60 ppm)
- Capacitance (passive) (optional) 10 nF - 1 μF (0.25%)
2080 17TH EDITION ELECTRICAL CHECK BOX electrical test equipment
Insulation Testers
RCD Testers
Loop Testers
Wiring Check
Included calibration checksheet for your instrument
2090 PROGRAMMABLE DECADE RESISTANCE BOX precision references and standards
0 - 10 kOhm
0.1% Accuracy (0.01% Accuracy option)
RS232 Interface
1 Watt power rating
Front panel display & controls
Virtual Front Panel software for PC
3000AC voltage reference precision references and standards
Calculable AC voltage reference source
Accuracy in the order of 10ppm
Traceable to any DC voltage multimeter with suitable accuracies
AC voltage with frequency to 1kHz
3000CS precision curent shunts precision references and standards
Precision current shunt array
Values 10mA through to 10A
1 year stability of up to 5ppm
4-Wire PT100 Output
Temperature coefficients of less than 0.6ppm/°C
3000HR precision resistance standard precision references and standards
Electrometer currents to 10nA
REsistance from 1 Mohm to 100 Gohm
Traceable to 1 GOhm standard
3000RS precision resistance standard precision references and standards
Decade resistances from 1 Ohm to 10MOhm
Temperature co-efficients as low as 0.1ppm/°C
Annual stabilities of better than 5ppm
Precision decade resistance reference
3000ZR precision zener reference precision references & standards
4 Banks of 10V and 1.018V outputs
Stability of better than 2ppm/year
Internal battery backup for transportation