Electricity Meter Test Equipment ELMA

The Electricity Meter Test Equipment ELMA due to modular concept enables to tailor specifications to specific laboratory demand Automated equipment for electricity meter testing The accuracy of the power and energy reference meter is available up to 0.01 %. The reference meter measures all main and influencing quantities inclusive harmonic analysis and distortion of the test signals. The available power and the maximum current of 240 A of extremely pure synthesized 4-quadrant test signal covers the needs of both precision and high capacity testing laboratories. The test signal can be created with user defined harmonic content and predefined signal shapes. The intelligent high resolution Local Evaluation Units use reflective optical sensors scanning the marks on meter's disk and passive sensors scanning the LED output of electronic meters. The sensors are insensitive to external light condition and possess auto-calibration capability eliminating manual adjustment. The optional optical communication channel enables simultaneous data exchange with electronic meters. The built-in remotely controlled dividers enable to evaluate high constant meters with light impulses up to 1 kHz. The handling system has capacity of several mobile meter trolleys with 20 tested meters each. The trolleys are prepared either for manual wiring of heavy current meters or can be equipped with quick-acting connectors for lower currents. Static version of handling system is also available. The optional precision electronically compensated transformers enable simultaneous test of electricity meters with interconnected current and voltage circuits. The wireless data acquisition Hand-Held Unit with integrated barcode laser scanner enables versatile local data acquisition from the tested meters. The supplied Control Software for Microsoft Windows enables multilingual operation with user definable vocabularies, user friendly configuration of testing procedures, database operations and Microsoft Office compatible user defined form of output documents to any system output device. Local net and database ensures automated data interchange, central evaluation and archivation in laboratories with multiple test equipments.

Brief specifications


More details

The accuracy of the power and energy reference meter is available up to 0.01 %. The reference meter measures all main and influencing quantities inclusive harmonic analysis and distortion of the test signals. The available power and the maximum current of 240 A of extremely pure synthesized 4-quadrant test signal covers the needs of both precision and high capacity testing laboratories. The test signal can be created with user defined harmonic content. The intelligent high resolution Local Evaluation Units use reflective optical sensors scanning the marks on meter's disk and passive sensors scanning the LED output of electronic meters. The sensors are insensitive to external light condition and possess auto-calibration capability eliminating manual adjustment. The optional optical communication channel enables simultaneous data exchange with electronic meters. The built-in remotely controlled dividers enable to evaluate high constant meters with light impulses up to 1 kHz. Suspension frame for 1, 2 or 3 positions is equipped with quick-acting connector system. The optional precision electronically compensated transformers enable simultaneous test of electricity meters with interconnected current and voltage circuits. The supplied Control Software for Microsoft Windows enables multilingual operation with user definable vocabularies, user friendly configuration of testing procedures, database operations and Microsoft Office compatible user defined form of output documents to any system output device. Optional local net and database ensures automated data interchange, central evaluation and archivation in laboratories with multiple test equipments.


ВимірюванняГенерація (Імітація)


Electricity Meter Test Equipment ELMA

The Electricity Meter Test Equipment ELMA due to modular concept enables to tailor specifications to specific laboratory demand Automated equipment for electricity meter testing The accuracy of the power and energy reference meter is available up to 0.01 %. The reference meter measures all main and influencing quantities inclusive harmonic analysis and distortion of the test signals. The available power and the maximum current of 240 A of extremely pure synthesized 4-quadrant test signal covers the needs of both precision and high capacity testing laboratories. The test signal can be created with user defined harmonic content and predefined signal shapes. The intelligent high resolution Local Evaluation Units use reflective optical sensors scanning the marks on meter's disk and passive sensors scanning the LED output of electronic meters. The sensors are insensitive to external light condition and possess auto-calibration capability eliminating manual adjustment. The optional optical communication channel enables simultaneous data exchange with electronic meters. The built-in remotely controlled dividers enable to evaluate high constant meters with light impulses up to 1 kHz. The handling system has capacity of several mobile meter trolleys with 20 tested meters each. The trolleys are prepared either for manual wiring of heavy current meters or can be equipped with quick-acting connectors for lower currents. Static version of handling system is also available. The optional precision electronically compensated transformers enable simultaneous test of electricity meters with interconnected current and voltage circuits. The wireless data acquisition Hand-Held Unit with integrated barcode laser scanner enables versatile local data acquisition from the tested meters. The supplied Control Software for Microsoft Windows enables multilingual operation with user definable vocabularies, user friendly configuration of testing procedures, database operations and Microsoft Office compatible user defined form of output documents to any system output device. Local net and database ensures automated data interchange, central evaluation and archivation in laboratories with multiple test equipments.

Featured Products

E-DWT 6531/6532 Electronic Deadweight Tester
E-DWT 6531/6532 Electronic Deadweight Tester
The E-DWT-H is used in the lab or instrument shop or can be taken into the field for performing in-situ calibrations and tests. This hydraulic pressure calibration system combines a high performance electronic reference pressure monitor and...
Код: E-DWT
PRTCalc
PRTCalc
PRTCalc is a free utility for those involved with PT100 platinum resistance thermometers. It allows for the accurate conversion of resistance to temperature or temperature to resistance. PRTCalc conforms with IEC 751 Amendment 2: December 1...
Код: PRTCalc
ISOTowers
ISOTowers
The most accurately defined temperatures are those defining points (fixed points) of ITS-90. The leading Primary Laboratories use large fixed point cells in deep calibration furnaces that utilise heat pipes to eliminate temperature gradient...
Код: ISOTowers
PDCR/PTX1800 Series Submersible Pressure Transducers
PDCR/PTX1800 Series Submersible Pressure Transducers
The PDCR1800 transducer (mV output) and the PTX 1800 transmitter (4 to 20 mA output) are the latest generation of fully submersible titanium high-performance sensors for the measurement of hydrostatic liquid levels. The 1800 Series incorpor...
Код: PDCR/PTX1800
PV210  Low-Pressure Pneumatic Vacuum Pump
PV210  Low-Pressure Pneumatic Vacuum Pump
The PV210 is a lightweight, yet rugged and durable, low pressure and vacuum hand pump offering exceptional fine control. Thermally insulated to eliminate hand held temperature effects and supplied with a built-in pressure relief valve to pr...
Код: PV210
Cyclops Model 878
Cyclops Model 878
The Cyclops Model 878 is a spherical blackbody source. It consists of an inner black sphere that sits inside a spherical furnace and is suitable for use as a radiation source for infrared thermometers. The inner sphere has a nominal diamete...
4.0000/5 2text_more_review
Код: 879
7334 Series of AC/DC Air Resistance Standards
7334 Series of AC/DC Air Resistance Standards
Guildline Instruments 7334 Series of AC/DC Air Resistance Standards are designed for high accuracy resistance calibration in air, without the need for stabilization in a temperature controlled bath. PRODUCT FEATURES Typical AC/DC Error ...
Код: 7334
Medusa 510
Medusa 510
Isotech have a wide range of Dry Blocks to suit probes requiring a large immersion depth. These products feature large and deep calibration volumes. As such they are less portable than the earlier Dry Blocks, but have higher capacities and ...
Код: 510
I-Cal EASY
I-Cal EASY
Use I-Cal Easy to automate sensor calibration, enter up to 20 calibration points and let the software set the bath, wait for stability and log the data automatically. Choose the stability criteria and how many points to record at each calib...
Код: EASY
DPI610E Hand-held pressure calibrator
DPI610E Hand-held pressure calibrator
The DPI610E combines effortless pressure measurement and generation, signal measurement and loop power with significantly improved pump capabilities and a powerful touch and button user interface. With a robust design, the unit has been ...
Код: DPI610E
Benchtop Water Activity Meter - Rotronic HygroLab
Benchtop Water Activity Meter - Rotronic HygroLab
The Rotronic HygroLab is an innovative high-end laboratory analyzer for water activity measurements with up to four measurement probe inputs. Simultaneous or asynchronous measurement with the tried-and-tested AW Quick measuring function for...
Код: HygroLab
8104 precision multimeter
8104 precision multimeter
The 8100 Series from Transmille is the most advanced multimeter available on the market. Featuring a full colour screen, the 8100 Series offers a wide range of functionality and covers a wide range of input parameters whilst achieving break...
Код: 8104
Rotronic PC33 - Analog RH and Temperature Probe
The PC33 series offers a comprehensive range of relative humidity probes for accurate, stable and repeatable measurements. Available with analog output signals, the PC series can be installed in a wide variety of applications...
Код: PC33
Cost-Effective Oxygen Analyser for Combustion - OXY-FLEX Series
Cost-Effective Oxygen Analyser for Combustion - OXY-FLEX Series
The XZR200 Oxygen Analyzer is suitable for measuring in oxygen closed systems, such as ventilation pipes and boiler exhaust flues. A cost effective zirconium-dioxide analyzer to measure percentage level oxygen in combustion processes, ambi...
Код: XZR200
9041A transportable multiproduct calibrator
9041A transportable multiproduct calibrator
The 9000A series range of multiproduct calibrators offers the widest workload of any calibration system presently available. The 9000A series provides all of the functionality of the 3000A series multiproduct calibrator in a dedicated rugge...
4.4000/5 5text_lot_review
Код: 9041A
2080 17TH EDITION ELECTRICAL CHECK BOX electrical test equipment
Designed with low cost, portability and ease of use in mind, the 2080 provides on or off site verification of RCD testers, Loop testers, Continuity and Insulation testers and multifunction testers. The 2080 is simple to use and provides the...
Код: 2080
AII GPR-18
The GPR-1800 series of intrinsically safe trace oxygen analyzers are designed for use in demanding process environments where the low detection limit down the AII’s industrial oxygen sensors can be well utilized. Typical for Analytical Indu...
Код: GPR-18
9334A SERIES of Resistance Standards
9334A SERIES of Resistance Standards
GUILDLINE INSTRUMENTS 9334A SERIES of Resistance Standards are designed as very stable laboratory standards for high accuracy resistance calibration in air, without the need for a temperature controlled bath. PRODUCT FEATURES 12 Month Stabi...
Код: 9334A
Oberon – for Slim Cells
Oberon – for Slim Cells
Model 426 is for Aluminium, Silver, Gold or Copper slim fixed point cells as well as for comparison calibration. Heat pipes provide the ideal conditions for the creation and maintenance of slim ITS-90 cells. The furnace core is a specially-...
4.2500/5 4text_more_review
Код:
Adapters
Adapters
A complete list of possible adapters is indicated in the specifications...