Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

CAL NotePad

- The purpose of Cal NotePad (CNP) is to automatically log and display the temperature of an Isotech calibration bath together with the unit under test. Cal NotePad can be used with baths (or indicators) without PC interfaces by the user typing in values from the keyboard.

Brief specifications


More details

The purpose of Cal NotePad (CNP) is to automatically log and display the temperature of an Isotech calibration bath together with the unit under test. Cal NotePad can be used with baths (or indicators) without PC interfaces by the user typing in values from the keyboard. The Cal NotePad can be used to identify the operator and the unit under test. With the click of a button data is logged with time information, it is also possible to log continually. The calibration bath temperature can be changed from the PC or from the calibration baths controller – Cal NotePad will display the temperature changes as they occur on the re-scalable chart display. For traceable calibration the unit under test should be compared to a calibrated standard thermometer. Cal NotePad can record the actual temperature of the bath from either the in-built indicator of an Isotech SITE model or from a variety of external instruments see list. If the external instrument has two channels (e.g. Isotech TTI) then the unit under test may be connected to channel B for logging with CNP. Alternatively the value can be typed in from the keyboard. Similarly the calibration bath controller value, actual temperature, SITE indicator value or unit under test value may also be entered manually. Then the manually entered data is combined with that gathered automatically and the resultant file can be opened in an external application such as Excel for the preparation of reports, certificates etc. Cal NotePad is designed for ease of use, it will give a chart of the system. When the operator determines the system is stable – easily seen from the chart then clicking a button will record time, operator, serial numbers of unit under test along with controller and indicator values. Cal NotePad can be used for semi-automatic calibration, see I-Cal Easy for a fully automated calibration solution.


ВимірюванняГенерація (Імітація)


CAL NotePad

- The purpose of Cal NotePad (CNP) is to automatically log and display the temperature of an Isotech calibration bath together with the unit under test. Cal NotePad can be used with baths (or indicators) without PC interfaces by the user typing in values from the keyboard.

Featured Products

Dew-Point Hygrometer - Michell Cermet II
A full specification on-line hygrometer for the measurement of dew point in air and process gases, with wide operating range and multiple display options...
Код: Cermet II
Mercury Triple Point Apparatus
The Isotech Model ITL-M-17725 apparatus is a self-contained, mechanically-refrigerated, system with a main well to house one mercury cell and two auxiliary wells for pre-chilling of thermometers. The cryostat temperature is adjustable from ...
Код:
PCR - Portable Calibration Rig
PCR - Portable Calibration Rig
  Request Information Service The PCR from Michell is a transportable gas blender in a flight case, suitable for calibrating a multitude of gas analyzers at virtually any location and has been designed to allow the blending of two or three...
Код: PCR
6535 RESISTANCE MEASUREMENT SYSTEM
6535 RESISTANCE MEASUREMENT SYSTEM
THE 6535 RESISTANCE MEASUREMENT SYSTEM IS THE MOST TECHNOLOGICALLY ADVANCED, HIGHLY MODULAR AND EASIEST TO USE HIGH RESISTANCE SYSTEM AVAILABLE ON THE MARKET TODAY PRODUCT FEATURES Two Modes of Operation, Bridge Mode and Direct Measurement ...
Код: 6535
PROCAL calibration software
PROCAL calibration software
Transmilles ProCal software provides a cost effective and easy to use solution for automating calibration, from a single workstation through to a network multi discipline network. ProCal comes pre loaded with drivers for many common instrum...
Код: PROCAL
ADT920, ADT920HV Pneumatic Pressure Test Pump
ADT920, ADT920HV Pneumatic Pressure Test Pump
The 920 and 920HV High Pressure Test Pumps are hand operated pressure pumps designed to generate pressure from 95% vacuum to 3,000psi (200bar). With a long lever, it just takes 40 seconds to reach 3,000 psi (200 bar). A high-quality screw p...
Код: ADT920
9337 SERIES OF PRECISION RESISTANCE STANDARDS
9337 SERIES OF PRECISION RESISTANCE STANDARDS
THE 9336 OR 9337 SERIES OF PRECISION RESISTANCE STANDARDS ARE EXCELLENT SOLUTIONS AS HIGH TO ULTRA HIGH LABORATORY RESISTANCE STANDARDS OR FOR PORTABLE APPLICATIONS REQUIRING HIGH ACCURACY WITH RESISTANCE VALUES FROM 10 MΩ TO 10 PΩ. PRODUCT...
Код: 9337
Meteorology RH and T Probes - Rotronic MP100A/MP400A
The MP100A is a combined humidity and temperature probe designed primarily for meteorological and general outdoor applications. Operation from DC voltage and low power consumption make the MP101A particularly suitable for operation at remot...
Код: MP100A/MP400A
COMPASS® for Pressure Calibration Software
COMPASS® for Pressure Software Pressure Calibration Management Software COMPASS® for Pressure Calibration Software is a universal platform for all of your pressure calibration software needs. From piston gauges calibrating individual devi...
Код: COMPASS® for Pressure
GA21 plus Portable gas analyser
GA21 plus Portable gas analyser GA21 plus is a portable analyser using advanced technologies. It can be equipped with up to 8 electrochemical and NDIR sensors. The analyser has a built-in pressure sensor, large internal memory for result...
Код: GA21
ADTS553F Air data test system
ADTS553F Air data test system
The ADTS553F air data test set is a portable three-channel flightline pitot static tester. It provides pitot static air data validation, leak testing, fault-finding and avionics instrumentation testing for any aircraft requiring angle of at...
Код: ADTS553F
3000AC voltage reference precision references and standards
The 3000AC provides laboratories with a fully traceable AC voltage source with accuracies in the order of 10ppm that can easily be verified with a DC voltage multimeter with accuracies in the 4ppm to 10ppm region. Using the latest in DAC te...
5.0000/5 2text_more_review
Код: 3000AC
Moisture in Liquid Analyzer - Michell Liquidew I.S.
Moisture in Liquid Analyzer - Michell Liquidew I.S.
Intrinsically safe moisture in liquids analyzer for fast, reliable on-line measurements. Continuous online measurement allows monitoring and control of processes to maximise efficiency for production and maintenance. Based on the Michell C...
Код: Liquidew I.S.
9334A SERIES of Resistance Standards
9334A SERIES of Resistance Standards
GUILDLINE INSTRUMENTS 9334A SERIES of Resistance Standards are designed as very stable laboratory standards for high accuracy resistance calibration in air, without the need for a temperature controlled bath. PRODUCT FEATURES 12 Month Stabi...
Код: 9334A
Additel 100 Pressure Hoses
Additel 100 Pressure Hoses
The Additel 100 series High Pressure Hose Test Kits are designed to extend your pressure calibrations to a convenient location to adapt from one pressure connection to another. Each test kit has 5 feet of flexible hose rated to 8,000 psi (5...
Код: ADT100
ISOTowers
ISOTowers
The most accurately defined temperatures are those defining points (fixed points) of ITS-90. The leading Primary Laboratories use large fixed point cells in deep calibration furnaces that utilise heat pipes to eliminate temperature gradient...
Код: ISOTowers
Self-Contained Hygrometer- Michell Drycheck
Self-Contained Hygrometer- Michell Drycheck
A simple and efficient, self-contained dew-point hygrometer, with filtration and flow control, for measurement of dew point or moisture content at point of use. It uses the Easidew On-Line to measure dew point in the range –100 to + 20 °C d...
Код: Drycheck
Parallel Tube Liquid Bath Model 915MWE
Parallel Tube Liquid Bath Model 915MWE
The Isotech Model 915 Liquid Bath is suitable has a wide temperature range, using silicon oils and other suitable liquids. All components in contact with the liquid are of stainless steel, and are insulated with materials which are complete...
Код: 915MWE
IO620-HOSE-P1-IS Pneumatic hose in hazardous area use
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Hazardous area use 1 m/3.28 ft pneumatic hose. Maximum pressure 400 bar/5800 psi...
Код: IO620-HOSE-P1-IS
Icarus
Icarus
Download Icarus – Evaluation Download Icarus Data Sheet Download Software Guide Icarus is designed to calculate and display the relationship between resistance and temperature for Standard Platinum Resistance Thermometers between the triple...
Код:
Спасибо!