ISOTowers

- 156°C to 660°C

- Isothermal Towers, ISOTower, are simple to use, and very robust. Operation is risk free, as a combined apparatus there is no need to handle a fragile cell. No need for specialist training courses. Isothermal Towers remove the mystery from fixed point calibration.

- High accuracy

- Fast to temperature

- Simple to use

Brief specifications


More details

The most accurately defined temperatures are those defining points (fixed points) of ITS-90. The leading Primary Laboratories use large fixed point cells in deep calibration furnaces that utilise heat pipes to eliminate temperature gradients. This combination of cell and furnace gives the smallest of uncertainties. In the patented Isothermal Towers the fixed point cell and heat pipe (or heat siphon) have been combined to produce the ideal realisations for calibrating standard thermometers. Thermometers can only be calibrated accurately if they are immersed sufficiently. In Isothermal Towers a heated block (Immersion Compensator, patent applied for) sits on top the heat siphon/cell to fully compensate for the immersion characteristics of the unit under test. The Isothermal Towers performance has been fully evaluated against the most detailed and demanding requirements ever written: CCT/2000-13. All Isothermal Towers; Indium, Tin, Zinc and Aluminium meet all the requirements of CCT/2000-13 allowing laboratories to realise the smallest uncertainties, at a fraction of the cost of conventional Metrology Furnaces with Primary Standard Cells. Introducing the ISOTOwers You can purchase three Isothermal Towers; Tin, Zinc and Aluminium for a similar price as one conventional cell and heat pipe apparatus Isothermal Towers are simple to use, and very robust. Operation is risk free, as a combined apparatus there is no need to handle a fragile cell. No need for specialist training courses. Isothermal Towers remove the mystery from fixed point calibration. Easily set to provide a melt or freeze of 24 hours or more, lending themselves for automatic calibration and providing your lab with an all day long plateau.


ВимірюванняГенерація (Імітація)


Документация

ISOTowers

- 156°C to 660°C

- Isothermal Towers, ISOTower, are simple to use, and very robust. Operation is risk free, as a combined apparatus there is no need to handle a fragile cell. No need for specialist training courses. Isothermal Towers remove the mystery from fixed point calibration.

- High accuracy

- Fast to temperature

- Simple to use

Featured Products

6640T SERIES OF TEMPERATURE BRIDGES
6640T SERIES OF TEMPERATURE BRIDGES
GUILDLINE’S NEW 6640T SERIES OF TEMPERATURE BRIDGES are redesigned to provide better uncertainties, faster measurement rates and more operational capability. PRODUCT FEATURES Best Accuracy: ± 0.015 ppm with 1 mA of Current Linearity: < ± 0....
Код: 6640T
Dew-Point Calibration System - Michell DCS
Dew-Point Calibration System - Michell DCS
The DCS system is a complete rack-mounted calibration station capable of producing a flow of air (or nitrogen) at a pre-specified range of dew-point temperatures from a minimum of -100°C (-148°F) to a maximum of +20°C (+68°F). Through custo...
Код: DCS
5030 SERIES
5030 SERIES
GUILDLINE INSTRUMENTS 5030 SERIES are precision air baths providing uniform constant temperature over a range of operating environments. To improve measurements and reduce the uncertainty contribution from temperature effects, these high qu...
Код: 5030
Rotronic CO2 Display for Indoor Air Quality Monitoring (CL11, CP11)
Rotronic CO2 Display for Indoor Air Quality Monitoring (CL11, CP11)
Indoor Air Quality (IAQ) measurements in offices, conference rooms, schools, etc. Application range: 0...50 °C / 0...95 %rh, non-condensing CO2 Measurement principle: Infrared (NDIR) with automatic calibration (ABC) CO2 Display Wal...
Код: CL11_ CP11
Self-Contained Hygrometer- Michell Drycheck
Self-Contained Hygrometer- Michell Drycheck
A simple and efficient, self-contained dew-point hygrometer, with filtration and flow control, for measurement of dew point or moisture content at point of use. It uses the Easidew On-Line to measure dew point in the range –100 to + 20 °C d...
Код: Drycheck
Extension Cables for Rotronic Humidity Probes HC2-A and HC2
Extension Cables for Rotronic Humidity Probes HC2-A and HC2
The HC2-A extension cables extend the HC2-A probes away from transmitters, handheld instruments or data loggers and data loggers. The HC2-A extension cables can be used up to 5 meters...
Код: HC2
HYGROLOG HL-20D - ECONOMICAL DATA LOGGER
HYGROLOG HL-20D - ECONOMICAL DATA LOGGER
The new HygroLog HL20 series is the latest development of data loggers for relative humidity, temperature, dew point and frost point. These loggers give you the accuracy and reliability to measure and record your essential data whether it b...
Код: HL-20D
Model 471 Simple Argon Apparatus
Model 471 Simple Argon Apparatus
The Isotech Argon Triple Point Apparatus is a robust, simple to use and affordable solution for the realisation of the argon triple point. Many laboratories use liquid nitrogen comparators which are convenient and can be low cost but the ni...
3.5000/5 6text_lot_review
Код: 471
3341A precision multiproduct calibrator
3341A precision multiproduct calibrator
The 33XXA Series multiproduct calibrators are modular versions of the class leading 3000A Series Calibrators. Designed to reduce cost, the 33XXA Series feature 0 - 20V DC output as standard with a wide range of options including 20V - 1000V...
Код: 3341A
IOHOSE-NP2 Pneumatic hose
IOHOSE-NP2 Pneumatic hose
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Safe area use 2 m/3.28 ft pneumatic hose. Maximum pressure 20 bar/300 psi...
Код: IOHOSE-NP2
Heavy Duty Transmitter Temperature and Humidity - Rotronic HF73A
Heavy Duty Transmitter Temperature and Humidity - Rotronic HF73A
The HF73A transmitter series is designed for fixed installation in industrial applications where conditions are within the range of 0 to 100 %rh and -100 to 150 °C (-148 to 302 °F). The probe of the HF73A can survive exposure to temperature...
Код: HF73A
ADT946A Hydraulic Pressure Test Pump
ADT946A Hydraulic Pressure Test Pump
The new Additel 946A Hydraulic Pressure Test Pump is a benchtop pressure pump designed to generate pressure to 15,000 psi (1,000 bar). This pump incorporates a dual-piston system which is ideal for filling large volume workload with the han...
Код: ADT946A
Simple Nitrogen Boiling Point Apparatus Model 461
Simple Nitrogen Boiling Point Apparatus Model 461
This model is a lower cost alternative to the ITL M 18205. This model is a simple apparatus open to the atmosphere comprising a stainless steel dewar flask filled with liquid Nitrogen, an insulating layer which houses a metallic equalising ...
Код: 461
P5515  Hydraulic Pressure Test Pump
P5515  Hydraulic Pressure Test Pump
These instruments are used for checking pressure measuring instruments against master test gauges, indicators or transducers. These hydraulic pressure comparators provide a quick and easy solution for checking pressure measuring instruments...
Код: P5515
IO620-BLANK Blanking plug
IO620-BLANK Blanking plug
Blanking plug Allows the PV621G and 622G to be used as pressure generators independently of the DPI620G and PM620 by blanking the PV62XG pressure module port. Not required for the PV623G as the port is self-sealing...
Код: IO620-BLANK
IO620-HOSE-P2 Pneumatic hose
IO620-HOSE-P2 Pneumatic hose
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Safe area use 2 m/3.28 ft pneumatic hose. Maximum pressure 400 bar/5800 psi...
Код: IO620-HOSE-P2
ADT104-HP Set of Adapters and Fittings
ADT104-HP Set of Adapters and Fittings
The Additel ADT104-HP is a high-pressure adapter kit designed to support various calibration and pressure testing needs. It includes a set of 17 adapters with a 1/4HP male (Autoclave M-250-C) connection, compatible with Additel models such ...
Код: ADT104
Compact Sampling System - Michell ES20
Compact Sampling System - Michell ES20
The ES20 Compact Sampling System is designed to reliably and accurately measure dew point or moisture content in a wide variety of industrial gas applications up to 20 barg. This sampling system is an economical and high-quality solution wi...
Код: ES20
Amplifier and digital Modbus / USB converter for Rotronic HC2(A) probes
Amplifier and digital Modbus / USB converter for Rotronic HC2(A) probes
The HC2-A extension cables extend the HC2-A probes away from transmitters, handheld instruments or data loggers and data loggers. The HC2-A extension cables can be used up to 5 meters. For longer cable runs, use the AC3003 signal amplifier ...
Код: HC2(A)
7340 Series features High Stability, Voltage Rated AC/DC Current Calibration Standards
7340 Series features High Stability, Voltage Rated AC/DC Current Calibration Standards
GUILDLINE INSTRUMENTS provides two series of the best performing, most compact, wide-band AC current shunts that are commercially available PRODUCT FEATURES High Current Values to 100 A AC/DC Difference Essentially Zero at Power Frequencies...
Код: 7340