Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

PEGASUS-T

- 150°C to 1100°C

- The Pegasus range offers extreme high temperature calibration in an easy to use portable package - ideal for the calibration of high temperature thermocouples. It has been designed for fast heating and finds applications in the glass, electrical power, automotive and material processing industries.

- Immersion Depth

- Calibrate Short Sensors

- Dynamic Heating Zone

Brief specifications


More details

New Solution…to Calibrate Short Sensors at High Temperatures The Pegasus range offers extreme high temperature calibration in an easy to use portable package – ideal for the calibration of high temperature thermocouples. It has been designed for fast heating and finds applications in the glass, electrical power, automotive and material processing industries. The Pegasus-T is the latest member of the Pegasus family developed for sensors that are simply too short to be calibrated in the Pegasus 4853 or other conventional calibration furnaces. The advanced control system allows the user to select optimal performance for sensors immersed at 25mm, 35mm or 50mm with three independent control loops. It also has built in over-temperature protection to protect the heater wire from over temperature thus increasing life expectancy. Immersion Depth Calibration engineers understand that to get the best accuracy temperature sensors should be immersed deeply into a calibration bath or furnace and compared to a reference thermometer. Calibrate Short Sensors But how to calibrate very short sensors such as those used in the automotive industry? These sensors are too short to go into conventional furnaces. The Isotech Pegasus Model 4853 has an immersion depth of 130mm which will suit many sensors but what if the sensor is very short, 25mm to 50mm? Large furnaces are unsuitable and calibrating these types of device provides a significant measurement challenge. Dynamic Heating Zone The new Pegasus-T has been developed for this very challenge and features a dynamic heating zone for short immersion probes providing a calibration source for sensors that are too short for other furnaces. It is being trialled and adopted at a number of customer sites in Europe and Asia and is now released for general sale. Pegasus-T allows you to choose an internal control sensor at the same depth the sensors under test, selecting from three internal noble metal control sensors or using an external control sensor placed at the same depth as the sensor under test. 1: Dynamic Heating Zone Choose one of three internal thermocouples to optimize performance for different length sensors. 2: Control From External Sensor Switch from the internal control sensor to an external Type R thermocouple that can be placed alongside the test sensor. 3: Independent Reference Channel Type R thermocouple input, can be used for external control or with a reference probe for an independent temperature measuring loop, option for UKAS calibration. Cautionary Note The operating life of the heater will vary with both the maximum operating temperature and the duty cycle. Units being used 24/7 at high temperatures may require a maintenance schedule for heater replacement Accuracy With short immersion probes there can be large errors as the sensor cannot be immersed deeply enough to allow it to reach the same temperature as the calibration block and there is a temperature gradient at the edge of the block. Tests show that the Pegasus-T is more useful than alternatives but there will always be a need to experiment and evaluate to determine the uncertainty for the conditions of use. It can be helpful to use a reference sensor of the same type as the units under test. Special Inserts We can design and manufacture inserts to suit your sensors… Calibration Blocks The Pegasus-T is supplied without an insert as most applications will require drilling to suit your requirement. Our CAD Designers can produce designs for your approval before manufacture in our workshop. Alternatively, we can provide blank inserts for you to manufacture or a pre-drilled insert with 6 x 5mm pockets, 100mm Deep. Advanced Features Fully featured high resolution display with advanced control features including multi loop control with autotune, adjustable temperature alarms with control from internal or external thermocouples Temperature Programmer Create, Edit and Store automatic programs for temperature stepping Reference Channel Input Can be used for external control or as a reference input. A Type R Thermocouple, Model 935-14-91 is included with each Pegasus-T Ethernet Interface Free Software, I-Cal Easy Log – web download Offset Elimination Connect the external reference probe and the calibrator can trim the block temperature to remove offsets USB Port Export logged data to a USB Key, controller data is continuously logged


ВимірюванняГенерація (Імітація)


PEGASUS-T

- 150°C to 1100°C

- The Pegasus range offers extreme high temperature calibration in an easy to use portable package - ideal for the calibration of high temperature thermocouples. It has been designed for fast heating and finds applications in the glass, electrical power, automotive and material processing industries.

- Immersion Depth

- Calibrate Short Sensors

- Dynamic Heating Zone

Featured Products

Interchangeable Humidity and Temperature Sensor - Michell HygroSmart I7000XP Series
The HygroSmart I7000XP sensor is designed to accurately and reliably measure relative humidity and temperature in a wide spectrum of industrial and heavy industrial applications. The sensor uses the latest HygroSmart 3 technology, providing...
Код: I7000XP
9333 SERIES of Air Resistance Standards
9333 SERIES of Air Resistance Standards
GUILDLINE INSTRUMENTS NEW 9333 SERIES of Air Resistance Standards are cost effective laboratory, portable or just general purpose resistance standards. They are very stable and are designed to be used across a wide temperature range. PRODUC...
Код: 9333
PROWEB web based certificate database
ProWeb enables creation of an online database of certificates in PDF format that can be accessed through a web portal. Enable simple access to historical certificates for both yourself and your customers, with password protected logins and ...
Код: PROWEB
Heavy Duty Transmitter Temperature and Humidity - Rotronic HF73A
Heavy Duty Transmitter Temperature and Humidity - Rotronic HF73A
The HF73A transmitter series is designed for fixed installation in industrial applications where conditions are within the range of 0 to 100 %rh and -100 to 150 °C (-148 to 302 °F). The probe of the HF73A can survive exposure to temperature...
Код: HF73A
4015 advanced multiproduct calibrator
4015 advanced multiproduct calibrator
The 4000 Series is aimed at laboratories, manufacturers and design facilities requiring a wide range of outputs with accuracies up to 8ppm. The 4000 Series builds on the trusted reliability of the 3000A series, offering an updated user inte...
Код: 4015
Process Sampling System - Michell ES70
Moisture analyzers are only as reliable as the sample extraction, handling and conditioning techniques used. The ES70 Sampling System range offers a set of configuration options to cover all process moisture and dew-point application needs,...
Код: ES70
Low Temperature Furnace
Low Temperature Furnace
Affordable Single Zone Furnace Simple Operation For Indium, Tin and Zinc Cells The Isotech Low Temperature Fixed Point Furnace is designed specifically to realize and maintain the freeze plateaux of Isotech Indium, Tin and Zinc Fixed Point ...
5.0000/5 2text_more_review
Код:
millisKanner Channel Expander
millisKanner Channel Expander
The millisKanner channel expander has eight input channels, and each can be configured individually for SPRT, PRT, Thermistor or Thermocouple input. This gives ultimate flexibility with no need for separate devices for resistance or thermoc...
Код:
P5551 Pointer Remover/Punch
The Fluke Model P5551 Pointer Remover/Punch is a specialized tool designed to efficiently remove and accurately refit the pointer of a pressure gauge. It is particularly useful for maintenance and calibration tasks involving pressure measur...
Код: P5551
Moisture in Natural Gas Analyzer - Michell OptiPEAK TDL600
Moisture in Natural Gas Analyzer - Michell OptiPEAK TDL600
The next generation TDLAS Analyzer for automatic online measurement of moisture in variable compositions of natural gas and biomethane. The OptiPEAK TDL600 Tuneable Diode Laser Analyzer employs the latest techniques in laser absorption spec...
Код: TDL600
ITS-90 Optimal Fixed Point Cells
ITS-90 Optimal Fixed Point Cells
Isotech Ultra Pure-Metal Freezing Point Cells are designed specifically to realize the liquid-solid equilibrium temperatures of certain high-purity metal elements, for calibration of thermometers at the ITS-90 Fixed Points. When you purchas...
Код: ITS-90
GL1010 SERIES
GL1010 SERIES
GUILDLINE INSTRUMENTS GL 1010 SERIES of Resistance Transfer Standards are very stable and low uncertainty calibration laboratory standards for customers looking to replace the old ESI 1010 series. PRODUCT FEATURES Transfer Accuracy better t...
Код: GL1010
Blackbody Source Model 989
Blackbody Source Model 989
Isotech first introduced the Model 988 to assist in relation to the SARS outbreak during the early 2000s. Used to increase the accuracy of thermal imagers being used to measure human skin temperature in temperature screening of applications...
5.0000/5 2text_more_review
Код: 989
AII GPR-7100 Portable PPM H2S Analyzer
The GPR-7500 analyzer utilizes the low-power electro-chemical sensor technology to provide a cost-effective and easy to maintain online-installation hydrogen sulfide measurement in a small package. The GPR-7100 is a portable H2S analyzer ve...
Код: GPR-7100
3041A precision multiproduct calibrator
3041A precision multiproduct calibrator
The 3000A Series multiproduct calibrators have been designed to help you and your business, allowing a wide range of calibration work to be performed quickly, accurately and economically. Modern calibration is a competitive market, and cost...
Код: 3041A
8 Way Selector Switches Models 954 and 958
8 Way Selector Switches Models 954 and 958
Isotech produces two eight way selector switches, one for resistance thermometers Model 954 and Model 958 for thermocouples. These switches have been designed for use in conjunction with our TTI range. The switches allow easy selection of c...
Код: 958
CAL NotePad
CAL NotePad
The purpose of Cal NotePad (CNP) is to automatically log and display the temperature of an Isotech calibration bath together with the unit under test. Cal NotePad can be used with baths (or indicators) without PC interfaces by the user typi...
Код: ePad
xTHP Hydraulic Calibration Test Pumps
xTHP Hydraulic Calibration Test Pumps
Whenever a high pressure calibration pump is needed, we offer several portable, hydraulic test pump models designed to work seamlessly with a reference gauge and process connection. The QTHP reaches test pressures up to 5000 psi (35 MPa) wh...
Код: xTHP
Gallium Fixed Point Cell
Gallium Fixed Point Cell
Second only to the Water Triple Point and in many ways, because of its ease of use and purity, superior to it, is the Gallium Melt Point. At 29.7646°C this is a very convenient temperature. Total Confidence Confidence is a major requirement...
Код: Gallium
CM Pressure module for PACE controllers
CM Pressure module for PACE controllers
Complete set of pressure modules for PACE 5000 and 6000 series controllers They have a wide measuring range up to 210 bar of pneumatic pressure. There is a wide range of measurement accuracy to choose from...
Код: PACE
Спасибо!