Categories
-
Pressure
-
Temperature
-
Humidity
-
Electrical signals
- Calibrator of electrical signals
- Reference multimeters
- Voltage, resistance, frequency standards
- Precision bridges
- Teraohmmeter
- Reference electricity meters
- Installations for verification of electricity meters
- Power analyzers
- Voltage dividers
- Current shunts
- Precision current transformers
- Systems for measuring current
- Precision measuring systems
- Test Equipment
- Liquid and air baths for resistance measures
- Standards of conductivity (salinity)
- Software
- Accessories
- Multifunction calibrators
-
Flow measurement
-
Chemical composition
-
Complex solutions
-
Services
Self-Calibrating Trace Moisture Analyzer - Michell QMA401
- Low Maintenance Quartz Microbalance Technology
- Features
-
- Precision measurement from 0.1 to 2000ppmV
- Fast response in both dry to wet and wet to dry transitions
- Simple, low cost, on-site maintenance with long service intervals
- Dryer can be replaced by the user in 10 minutes
- Accuracy of 0.1ppmV or 10% of reading, whichever is greater
- Intuitive user interface
- Ethernet or USB digital communications
- SD card data logging
- Optional internal sample handling and bypass loop
Process Moisture Analyzer - Michell QMA601
- Measurement range: 0.1...2000ppmV
- Accuracy: ±10% of reading from 1 to 2000ppmV
- ±0.1ppmV between 0.1 & 1ppmV
- Inlet pressure: 2 barg
- Sample flow: 300ml/min total flow
- Analog signals: 2 x 4...20 mA or 1...5 V (selectable)
- Maximum load resistance 500 Ω for 4...20 mA and minimum load of 1M Ω for 1–5 V Digital communications: RS485 ModBus RTU Modbus TCP
Process Moisture Analyzer - Michell Promet I.S
- Multi-Channel Moisture Measurement in Process Gases
- Features
-
- Simple, cost efficient operation and low-maintenance
- Immune to chemical attack from H2S, mercaptans and other sulphides
- Protected against glycol or other liquid contaminants
- Accurate direct dew-point measurement at process pressure up to 45 MPa
- Moisture range from ambient to ppb level with exhaustive list of hygrometric units, including key parameters of natural gas
- Two 4-20 mA configurable outputs and digital Modbus RTU based communication
- Assured calibration integrity traceable to NPL (UK) and NIST (USA)
- User programmable or real-time active pressure compensation for moisture content calculation
- Multichannel with up to 4 independent measurement channels
- Customer configurable ES70 sample systems
Process Moisture Analyzer - Michell Promet EExd
- Natural Gas Water Dew-Point Analyzer
- Features
-
- EExd flameproof certified - IECEx, ATEX, cQPSus and TC TR Ex
- Complete hazardous area installation
- Single- or dual-channel measurement
- Moisture content, dew point and pressure
- Calibration traceable to NPL (UK) and NIST (USA)
- Range -120 to +30°Cdp (-184 to +86°F), 0.001 to 30,000 ppmV
- Remote global access options
- Sour gas compatible
- Field calibration maintenance
Moisture in Natural Gas Analyzer - Michell OptiPEAK TDL600
- Fast and Precise Moisture Measurement in Natural Gas
- Features
-
- D-MET system: Factory-ready for varying gas compositions. For example, after stream blending or injection of shale gas or biomethane to a network.
- Operating range down to 1 ppmV
- Sour gas compatible
- Simple installation and setup
- Lowest maintenance
- IECEx, ATEX and cQPSus certified for EExd flameproof
- Integrated sample handling
- Proven Michell Instruments quality: 40 years of expertise in moisture measurement built into the design
Moisture in Liquid Analyzer - Michell Liquidew I.S.
- For Moisture Measurement in Process Liquids
- Features
-
- Simple, cost-efficient operation and low maintenance
- Retrofit functionality, easy to integrate into existing sampling or distribution systems
- High integrity moisture in liquid measurement from 0.01 ppmW to saturation point
- Multi-channel with up to four completely independent measurement channels
- Robust design for undisturbed operation in many non-polar liquids over a long time
- Two 4-20 mA configurable outputs and digital Modbus RTU-based communication
- Replaceable sensor element with Michell Calibration Exchange Service for reliable cost-efficient calibration
- NIST and NPL traceable calibration
Michell Condumax II and OptiPEAK TDL600 Dew-Point Analyzer
- Hydrocarbon Dew Point and Moisture Analyzer for Natural Gas
- Features
-
- Moisture:
- Measurement range: 1ppmV to 1000ppmV.
- Measurement technology: Tuneable Diode Laser Spectroscopy.
- Latest generation of TDLAS – moisture measurements are independent to changes in background gas composition.
- Class-leading accuracy ±1ppmV even with widely varying gas compositions.
- Hydrocarbon Dew-Point:
- Fully automatic analysis.
- Fundamental chilled mirror principle.
- HCDP measurement range: up to ∆ 55K measurement depression from main unit operating temperature.
- HCDP measurement technology: direct photo-detection of hydrocarbon condensate.
- General:
- Low maintenance.
- Easy to install with a small footprint.
Industrial Humidity Transmitters HVAC - Rotronic HygroFlex HF3 and HF4
-Application range: Temperature: -40…60 °C/ -50…100 °C;
Humidity: 0…100 %rh
Accuracy at 23°C: Temperature: ±0.1 K/±0.2 K ±/0.3 K
Humidity: ±2.0%rh / ±1%rh
Output analogue signal: 0...1 V, 0...5 V, 0...10 V, 0...20 mA, 4...20 mA
Power Supply: 2-wire: 10…28 VDC/ 20…28 VDC; 3/4 wire: 18…40 VDC / 13…28 VAC
Connections: Analogue signals on screw terminals; Models with Ethernet(LAN), RS-485
Hydrocarbon Dew-Point Analyzer - Michell Condumax II
- On-Line Dew-Point Analysis in Natural Gas
- Features
-
- Fully automatic on-line analysis
- Objective, highly repeatable measurements
- 0.5°C hydrocarbon dew-point accuracy
- Fundamental chilled mirror principle
- Patented detection technique
- Self-cleaning
- No purge or cooling gas required
- Optional water dew-point analysis
- Modbus RTU
- IECEx, ATEX, cQPSus and GOST Ex certifications
Humidity Transmitter HVAC - Rotronic HygroFlex HF1
-Operating and measurement range: -20...50 °C 0...100 %RH (non-condensing)
Accuracy: type W & type D at 23°C ± 2 %RH; type S at 23°C ± 3 %RH (10...90 %RH)
Temperature precision at 23 °C: ± 0.3 °C
Outputs: 2 analog outputs 04...20 mA
Supply voltage: 12...28 VAC / 15...40 VDC
High End Humidity Transmitters - Rotronic HygroFlex HF5 and HF8
-Application range: -50...100°C/ -100...200°C; 0…100 %rh
Accuracy @ 23 °C: ±0.8 %rh/ ±1.2 %rh
Connections: Models with Ethernet (LAN), RS485, USB and analogue signals on screw terminals
Long-Term Stability: <1 %rh / year
Memory capacity: 2000 values/10000 values (%rh and °C)
Data logger for humidity, temperature, pressure and dewpoint HL-1D / BL-1D / TL-1D
-Humidity measurement: 0...100 %rh; ±2%rh @ 23°C (10…90 %rh) ±5%rh others
Temperature: -30...70 °C
Pressure: 300…1100 hPa; ±3hPa @ 0…65°C / ±5hPa others
Application range: -30...70°C; 0...100 %rh
Communication: USB-Mini port
ATEX Humidity and Temperature Transmitter - Rotronic HF5-EX
-Measurement range: 0…100 %RH
Accuracy at 23°C: 0.8 %RH
Temperature Measurement range: -40…60 °C or -40...85 °C
Application temperature: Housing/electronics -40…60 °C without display -10…60 °C with display
Analogue output: 4…20 mA, two-wire

-350x280.jpg)
-350x280.jpg)





-350x280.jpeg)




































