Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

7050LP Low Pressure Indicator

- Pressure measuring range up to 250 mbar

- Uncertainty up to 0.005%

- Two ranges in a single instrument

- Quartz Bourdon Tube Sensor

- Vacuum reference measuring (option)

- Automating pressure test and calibration

Brief specifications

Three pressure measurement ranges up to 250 mbar

Measurement Uncertainty up to ±0.005%

Two ranges in a single instrument

Quartz Bourdon Tube Sensor

Vacuum reference measuring (option)

Absolute pressure measurement mode from vacuum (option)

Automating pressure DUT test and calibration

Automatic correction for head pressure differences

Versatility to work with any type of pneumatic pressure

Liquid trap for protection system (option)

More details

The 7050LP low pressure digital pressure indicator, part of the versatile Series 7250 family, is specifically designed to meet the demanding performance requirements of calibrating low pressure sensors, transducers, mechanical gauges, portable calibrators and their plug-in modules. To accommodate bidirectional devices, the 7050LP can be supplied to operate in both positive and negative gauge modes. The 7050LP offers unmatched performance and measurement precision. Utilizing multiple ranges in a single instrument, the 7050LP combines precision, stability, and affordability. The 7050LP has a unique quartz sensor, the most accurate pressure sensing technology available in a digital pressure calibrator. Each quartz sensor is manufactured and tested to provide the ultimate performance required by a Fluke Calibration pressure calibrator, ensuring that every customer receives the highest quality, precision and stability in their instrument. Advanced precision The 7050LP is available in three different range configurations, each a dual range instrument. Select either the 10 inH20 and 30 inH2O combination, or the 20 inH2O and 60 inH2O or the 35 inH2O and 100 inH2O range combination. Each combination provides a precision to 0.005 % of reading from 10 to 100 % of the higher range. For pressures from 0 to 10 %, the precision is a fixed error equal to 0.005 % of 10 % FS. This unmatched precision is achieved by the unique quartz pressure sensing technology that puts the pressure in direct contact with the quartz element, eliminating mechanical linkages and metal diaphragms. Since this is a differential sensor, the reference side of the 7050LP can be connected to the reference side (low side) of the device under test. Therefore, disturbances due to room drafts, HVAC systems and opening/closing doors, which can have a detrimental effect on the calibration process, are eliminated. The 7050LP provides both unequalled precision and excellent long term stability due to the inherent properties of quartz. For example, the total uncertainty for a 10/30 inH2O range combination over a one year calibration interval is 0.009 % of reading or 0.00015 inH2O (whichever is greater). Automating pressure test and calibration The 7050LP is easy to use and can be automated through the remote interface. The 7050LP is provided with both an RS-232 and IEEE-488 interface, and syntax for all Series 7250s follows SCPI protocol for easy programming. COMPASS® for Pressure, an off-the-shelf software package, is available. A LabVIEW® driver is available as a free download. As a standard feature, software written for the previous generation Series 7215, 7010 and 6000 instruments is fully supported by the 7050LP. The 7050LP can be set to 510 emulation mode to use software originally written for the DPI 510. Firmware updates can be performed over the RS-232 interface (updates can be downloaded from the web site). A MET/CAL® software driver is available. Versatility to handle any pneumatic pressure calibration The 7050LP is versatile enough to handle almost any type of low pressure calibration. Dual range: The 7050LP has two ranges in one instrument, 10 inH2O and 30 inH2O, or specify the 20 inH2O and 60 inH2O or the 35 inH2O and 100 inH2O range combination. The 7050LP will automatically change ranges to ensure the highest performance at the requested pressure. Pressure units/scales: The 7050LP includes more than 12 standard units of measure, including inH2O at 4 °C (39 °F), 20 °C (68 °F), and 16°C (61 °F), in Hg at 0 °C (32 °F) and 16 °C (61 °F), kPa, bar, psi, kg/cm3, mm Hg at 0 °C (32 °F), cm Hg at 0 °C (32 °F), and cm H2O at 4°C (39 °F), and two user-defined units. Head pressure: The 7050LP automatically corrects for head pressure differences. Accredited Calibration Report: The 7050LP comes standard with an accredited calibration report. Options The 7050LP can be provided for gauge mode operation, or with: Vacuum (negative gauge) mode for bidirectional devices Rack mount kit


ВимірюванняГенерація (Імітація)


7050LP Low Pressure Indicator

- Pressure measuring range up to 250 mbar

- Uncertainty up to 0.005%

- Two ranges in a single instrument

- Quartz Bourdon Tube Sensor

- Vacuum reference measuring (option)

- Automating pressure test and calibration

Featured Products

Hydra Model 798H
Hydra Model 798H
Precision calibration of thermometers calls for the use of stirred liquid calibration baths. The Hydra models set new standards in terms of price to performance ratio. Now Calibration Engineers and Metrologists can choose from a range of ba...
Код: 798H
ADT783 Pressure Controller
ADT783 Pressure Controller
These modular pressure controllers combine cutting-edge control/measurement technology, modular design, and user-friendly features. The Additel 783 controller series is optimized for high speed to pressure without compromising accuracy and ...
Код: ADT783
Flexible Current Transformer FCT 2161
Flexible Current Transformer FCT 2161
Precision Flexible AC Current Transformer SymmProFlex® FCT 2161 is based on Rogowski principle designed to measure alternating current and to transform the measured current to standardized 5 A level...
Код: 2161
OEM Transmitter Temperature and Humidity - Rotronic XB32A
OEM Transmitter Temperature and Humidity - Rotronic XB32A
The XB32A OEM transmitter consists of a cable probe and PCB without housing. Thanks to its compact size, high accuracy and various selection possibilities, the transmitter can be adapted to customer wishes and used practically everywhere...
Код: XB32A
RH and Temperature Probe Calibrator - Rotronic HygroGen 2
RH and Temperature Probe Calibrator - Rotronic HygroGen 2
The HygroGen2 is a generator of controlled relative humidity and temperature environments, primarily for use in calibrating humidity instrumentation, but is also well suited to the calibration of temperature instrumentation, particularly ...
Код: HG2
Moisture in Natural Gas Analyzer - Michell OptiPEAK TDL600
Moisture in Natural Gas Analyzer - Michell OptiPEAK TDL600
The next generation TDLAS Analyzer for automatic online measurement of moisture in variable compositions of natural gas and biomethane. The OptiPEAK TDL600 Tuneable Diode Laser Analyzer employs the latest techniques in laser absorption spec...
Код: TDL600
PROGRAPH Measurement Analysis Software
Software Designed to be used in conjunction with the 8000 Precision Multimeter Series and 8500 Low Thermal Scanner, ProGraph provides an instant solution for graphing stability, temperature and many other parameters. ProGraph is a 'plug and...
Код: PROGRAPH
Multi Junction Laboratory Probes
Multi Junction Laboratory Probes
Probes are suitable for use with all Isotech thermocouple reference units or may be used with any other equipment including ice flasks and ice point reference units. They can be supplied to suit a single thermocouple, or up to ten double ju...
Код:
LMF – System for high precision flow measurement of gas and air
LMF – System for high precision flow measurement of gas and air
LMF® – LaminarMasterFlow® High-precision flow measurement of gas and air The EP LMF® – LaminarMasterFlow® is a complete system for high precision flow measurement of gas and air (volume and mass flow). The LMF® system consists of a fl...
Код: LMF
Oxygen Combustion Control Analyzer - Michell XZR500
Oxygen Combustion Control Analyzer - Michell XZR500
The XZR500 oxygen analyzer from Michell Instruments is designed to determine the excess air required for optimum combustion. It uses advanced Zirconium Oxide technology to measure levels of oxygen in harsh conditions such as boilers, incine...
Код: XZR500
Oberon – for Slim Cells
Oberon – for Slim Cells
Model 426 is for Aluminium, Silver, Gold or Copper slim fixed point cells as well as for comparison calibration. Heat pipes provide the ideal conditions for the creation and maintenance of slim ITS-90 cells. The furnace core is a specially-...
4.2500/5 4text_more_review
Код:
Additel 850 Laboratory Thermocouple Calibration Furnaces
Additel 850 Laboratory Thermocouple Calibration Furnaces
Thermocouple calibration work can be challenging. Here at Additel, we understand the difficulties of this type of work. Traditional furnace designs require several individual devices to meet industry standards for various calibration applic...
Код: ADT850-1200
PACE5000 Pressure Controller
PACE5000 Pressure Controller
The Pneumatic Druck PACE5000 / PACE6000 Modular Pressure Controllers bring together the latest control and measurement technology to offer an elegant fast flexible and economical solution to pressure control for automated production, test a...
Код: PACE5000
2271A Pressure Controller & Calibrator
2271A Pressure Controller & Calibrator
The Fluke Calibration 2271A Industrial Pressure Calibrator provides a complete, automated solution for calibrating a wide variety of pressure gauges and sensors. Thanks to its modular design, it can be configured to meet different needs and...
Код: 2271A
AII GPR-3100 Oxygen Purity Analyzer
Our range of oxygen analyzers are designed to monitor gas produced or used in industrial processes where trace oxygen from low parts per million to pure O2 must be precisely measured. Utilizing AII’s high performance galvanic oxygen sensors...
Код: GPR-3100
Dew-Point Transmitter - SF52
Dew-Point Transmitter - SF52
The SF52 dew-point transmitter is a simple, cost effective moisture sensor designed for use in harsh industrial dryer applications. It is reliable and tough enough to withstand the high temperatures often associated with industrial drying. ...
Код: SF52
Quick Cal High
Quick Cal High
Isotech’s Quick Cal range of testers are ideally suited to the less exacting applications where our larger, better specified baths are unnecessary. The Low Temperature Quick Cal covers the temperature range of -12°C to +140°C, making it ide...
Код: Quick Cal High
microK Gold
microK Gold
microK GOLD – a unique package Best performance, documented, guaranteed with an unmatched satisfaction promise. Award Winning In April 2017 Isotech won a Queen’s Award for Enterprise in the Innovation category for the co-development of the ...
Код: Gold
Process Moisture Analyzer - Michell Promet EExd
Process Moisture Analyzer - Michell Promet EExd
Promet EExd Process Moisture Analyzers are hazardous-area rated industrial hygrometer systems for measurement of water vapor content in process gases on natural gas platforms and terminals as well as in petrochemical plants and industrial m...
Код: Eexd
IOHOSE-NP2 Pneumatic hose
IOHOSE-NP2 Pneumatic hose
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Safe area use 2 m/3.28 ft pneumatic hose. Maximum pressure 20 bar/300 psi...
Код: IOHOSE-NP2