Additel 878 Reference Dry Well Calibrator

- Three models from -40℃ to 700℃

- Reference level of accuracy

- The best stability and homogeneity

- Large touch display

- Wi-Fi and Bluetooth wireless technologies

Brief specifications


More details

Additel takes temperature calibration to the next level with the ADT878 reference dry block calibrators. If you're looking for the best dry-block calibrator on the market, you've found it! Additel's commitment to continuous improvement, quality and efficient working time savings is fully embodied in the ADT878 series. Choosing from three models ranging from -40 to 700 °C, you will find the perfect solution for your calibration. The Process Calibrator option adds a separate input for an external PTO reference, dual-channel readout for the HRTs under test, and a full suite of capabilities to help with everything from measuring temperature sensor signals to calibrating thermocouples, as well as self-calibrating the reference dry-block calibrator and setting up HART transducers. Each unit comes standard with a large touchscreen display, dual-zone temperature control and Additel's commitment to the best customer service in the industry. The calibrator interface has nine localizations, including English and Ukrainian. We're sure you'll be delighted with the impressive performance of these state-of-the-art dry-block calibrators!

Process Calibrator option

Each model can be purchased with a Process Calibrator (PC) option. This option combines a wealth of useful features combined into a full-featured documenting process calibrator with built-in HART communicator and reference-level dry-block temperature calibrator. This option includes the ability to measure the reference PTO signal with virtually any type of connection and to measure signals from two devices under test with the ability to measure mA, voltage, temperature relay, PTO or thermocouple. Calibrations of the most common types of PTO and thermocouples are already included in the internal software of the calibrator, other calibrations are also possible by additional order. In addition to these measurement functions, you have full documentation capability with the creation of automatic calibration jobs, saving of initial and post-adjustment results, and the ability to communicate with a HARTsmart transmitter. The Process Calibrator option also features a built-in full-featured HART switch that allows users to read, configure, and calibrate HART transducers. The screen snapshot function allows you to capture all the information displayed on the display with just one click. This option allows you to record the data of all channels during the implementation of the automatic step function. Using a reference PTO, you can also choose to control the dry-block thermostat setpoint temperature by the value of either the built-in sensor or an external reference PTO.

Self-calibration

We are convinced that using an external reference sensor as a standard is the best choice for temperature calibrations. However, we also recognize that this method is not always necessary and convenient, and depending on specific applications, using an internal built-in reference sensor may be a more rational alternative. Traditionally, the internal control sensor has lower accuracy, which is largely due to its long-term drift. The built-in self-calibration function allows you to automatically calibrate the internal reference sensor using your external standard. In just a few clicks, the calibration will run automatically, giving you a new, traceable calibration of the internal sensor, improving its accuracy as you don't have to account for its long-term drift if you decide to use it as a reference.

Automation functions

Traditionally, dry-block thermostats were simply a steady source of heat. To increase the ease of use of our reference dry block calibrators, we have added automation features that allow these amazing devices to be used as a highly stable heat source, a triple water point apparatus, and as an annealing furnace. In conjunction with the ADT878-TPW-KIT, the ADT878-160 Dry Block Reference Calibrator can be used to automatically reproduce and maintain the triple point water ampoule. Traditional methods require time and deep practical skills to reproduce the triple point of water (TPW). Additel has simplified this process with the feature of automatic realization of PTV. Simply insert the PTO ampoule into the well of the reference dry block calibrator and run the appropriate procedure. The automatic program will notify you when the ampoule reaches the state of hypothermia. Remove the ampoule and shake it, then you can maintain the PTV simply by reimmersing the ampoule in the calibrator well. In this way, you will be able to control the drift of your PTO. For more information, please see the technical information for the ADT878-TPW-KIT. When you buy our reference 700 °C dry block temperature calibrator, you will find, among other things, an automatic function technical annealing of PTO. We have preset annealing procedures that set a specific annealing time, temperature and cooling rate. You can also create your own annealing routines.

Together with the Additel calibrators of the ADT878 series, you can order the Additel protective transport case 9915-878, which provides protection of the equipment located inside from various mechanical damages such as shocks (including falls) and vibrations.


ВимірюванняГенерація (Імітація)


Additel 878 Reference Dry Well Calibrator

- Three models from -40℃ to 700℃

- Reference level of accuracy

- The best stability and homogeneity

- Large touch display

- Wi-Fi and Bluetooth wireless technologies

Featured Products

P5543 Angle Adapter
To calibrate gauges with the pressure connection on the rear (for example, panel mount gauges) in their correct operating position, an angle adaptor should be used. The angle adapter uses the standard gauge adapters and positions the gauges...
Код: P5543
New Reference Standard
New Reference Standard
The Reference Standard RS 3330 is designed for the highest possible precision meter for quantities related to electrical power and energy measurements. The Reference Standard is designed to meet all requirements put on a reference standard ...
Код: New Reference Standard
Multi Junction Laboratory Probes
Multi Junction Laboratory Probes
Probes are suitable for use with all Isotech thermocouple reference units or may be used with any other equipment including ice flasks and ice point reference units. They can be supplied to suit a single thermocouple, or up to ten double ju...
Код:
Medusa 511
Medusa 511
Isotech have a wide range of Dry Blocks to suit probes requiring a large immersion depth. These products feature large and deep calibration volumes. As such they are less portable than the earlier Dry Blocks, but have higher capacities and ...
Код: 511
Standard Thermocouple Model 1600
Standard Thermocouple Model 1600
The Isothermal range of Thermocouple Standards are the result of many years development. The type R and S standards will cover the range from 0°C to 1600°C. The measuring assembly comprises a 7mm x 300mm or 600mm gas tight 99.7% recrystalli...
Код: 1600
ACal (9530) Calibration Software
ACal (9530) Calibration Software
Additel ACal (9530) is a powerful software package designed for varying degrees of automation of calibrations and management of your laboratory. ACal combines pressure and temperature instrument calibration automation features with laborato...
Код: Acal
Miniature Fixed Resistor Model 836
Isotech produces a miniature resistor with ultra-low temperature coefficient and ultra-high stability. This is achieved because the resistors are oil filled and hermetically sealed. The function of hermetic sealing is to eliminate the ingre...
Код: 836
9334A SERIES of Resistance Standards
9334A SERIES of Resistance Standards
GUILDLINE INSTRUMENTS 9334A SERIES of Resistance Standards are designed as very stable laboratory standards for high accuracy resistance calibration in air, without the need for a temperature controlled bath. PRODUCT FEATURES 12 Month Stabi...
Код: 9334A
Humidity and Temperature Probe Calibrator - Michell OptiCal
Humidity and Temperature Probe Calibrator - Michell OptiCal
The OptiCal is a premium, self-contained calibrator for humidity sensors. It features an integrated chilled-mirror reference which enables the operator to perform calibrations that are traceable to national standards. The calibration chamb...
Код: OptiCal
DG2, DG3, DG4 and VDS3 - Michell Dew-Point Generators
DG2, DG3, DG4 and VDS3 - Michell Dew-Point Generators
The Michell range of dew-point generators provides flexibility and control at a competitive price. Based on the volumetric mixing of dry and wet gases, the instruments can be controlled either manually or automatically to suit a wide range ...
Код: DG
Ice mantle maker for water triple point cells
Ice mantle maker for water triple point cells
Are you fed up with cold wet hands, and hours of frustration when you produce an ice mantle in your Triple Point Cell? Change your life and try the Isotech Ice Mantle Maker. It works by using a specially designed anti-gravity heat pipe. The...
Код: Ice mantle
Precision Chilled Mirror Hygrometer - Michell S8000
Precision Chilled Mirror Hygrometer - Michell S8000
The S8000 precision hygrometer provides a direct measurement of dew point, temperature and pressure. Suitable for both industrial and laboratory applications, the instrument is compact and self-contained. Dew-point measurement is based on ...
Код: S8000
Thermo-Paramagnetic Oxygen Analyzer - Michell XTP501
Thermo-Paramagnetic Oxygen Analyzer - Michell XTP501
A lightweight oxygen analyzer or transmitter for cost-effective quality control in safe area applications, such as monitoring oxygen purity. Using Michell’s tried and tested Thermo-Paramagnetic oxygen sensing technology the XTP501 has no co...
Код: XTP501
OEM Transmitter Temperature and Humidity - Rotronic XB32A
OEM Transmitter Temperature and Humidity - Rotronic XB32A
The XB32A OEM transmitter consists of a cable probe and PCB without housing. Thanks to its compact size, high accuracy and various selection possibilities, the transmitter can be adapted to customer wishes and used practically everywhere...
Код: XB32A
Michell Condumax II and OptiPEAK TDL600 Dew-Point Analyzer
Michell Condumax II and OptiPEAK TDL600 Dew-Point Analyzer
Hydrocarbon dew point (HCDP) and moisture are key quality parameters to ensure the quality of pipeline transmission gas. With the combined Condumax II and OptiPEAK TDL600 analyzer system pipeline operators have the assurance of the most wid...
Код: TDL600 Dew-Point
787 Model
787 Model
The Model 787 calibrator redefines industry standards by blending industry leading performance and speed of operation within a robust design tailored for extreme conditions. The maximum operating temperature is 660°C allowing wide range of ...
Код: 786
IO620-USB-PC USB cable
USB cable Connects the DPI620G or DPI620G-IS to a PC...
Код: IO620-USB-PC
6645Q Quantum Hall System
Guildline's 6645Q Quantum Hall System has been designed and developed to meet the needs of Standards Laboratories around the world for an improved level of accuracy in the calibration and maintenance of primary resistance standards. PRODUCT...
Код: 6645Q
Extension Cables for Rotronic Humidity Probes HC2-A and HC2
Extension Cables for Rotronic Humidity Probes HC2-A and HC2
The HC2-A extension cables extend the HC2-A probes away from transmitters, handheld instruments or data loggers and data loggers. The HC2-A extension cables can be used up to 5 meters...
Код: HC2
P5510  Pneumatic Pressure Test Pump
P5510  Pneumatic Pressure Test Pump
This pneumatic pressure comparator is designed for testing pressure measuring instruments against master test instruments. This cost effective instrument provides precise control for important calibration requirements and include many featu...
Код: P5510
Спасибо!