7252/7252i Pressure Controllers

- Pressure regulation up to 172 bar

- Control stability 0.001%

- Uncertainty up to 0.003%

- Two precision pressure modules

- Barometric reference (option)

- Protection overpressure for the DUT

Brief specifications

Pressure measurement and regulating ranges 0.4 to 172 bar

Control stability up to 0.001%

Total uncertainty pressure measure up to 0.003%

Two models to choose from, 7252i or 7252

Automatic correction for head pressure differences

Autovent and autozero

Two precision pressure modules in one device

Barometric reference (option)

Protection overpressure for the DUT

Automating pressure test and calibration

More details

Adding to the flexibility of the Series 7252, two performance models are available: the Model 7252i that offers percent of reading performance further extending the capabilities of a single calibrator, or the Model 7252, that provides percent of full scale (FS) performance for each range. The Model 7252i provides a precision of 0.005 % of Reading from 25 % to 100 % of each installed range. For pressures below the lower threshold of 25 %, the precision becomes 0.005 % of the 25 % value. Alternatively, the Model 7252 provides a precision of 0.003 % of FS for each installed range. Both models provide a one year stability of 0.0075 % of Reading allowing a one year calibration interval. Both the 7252i and 7252 are available in a variety of pressure ranges. Choose from any pressure range combination from as low as 10 inH2O (25 mbar) up to 2500 psi (172 bar). For example, either the Model 7252 or 7252i can be configured with a lower pressure range of 10 psi (1 bar) and an upper range of 1 000 psi (70 bar). Or, a Model 7252i could include a 10 inH2O (25 mbar) range and 2 500 psi (172 bar) to cover very low and very high pressure calibration requirements. Only Fluke Calibration provides such a broad pressure range coverage factor in a dual output pressure controller. For absolute mode calibrations, the Series 7252 can be supplied with a Barometric Reference option, or the Vacuum Reference option where a vacuum pump is connected to the reference port(s). While the former offers a high degree of convenience by allowing instantaneous transition from gauge to absolute mode, the Vacuum Reference option provides the ultimate performance solution, since it does not introduce the additional uncertainty of a secondary, barometric sensor. Instruments with the Vacuum Reference option include an on-board vacuum sensor to allow fully automatic zeroing when operating in absolute mode. For applications where absolute calibrations are performed exclusively, permanent absolute ranges to 50 psia (4 bar) are available. The Series 7252 also provides negative gauge operation to support the calibration of a wide variety of test devices and applications. The Series 7252 is a dual output pressure controller, which increases throughput, while providing maximum stability for each range. With simultaneous pressure control, it can actually perform two calibrations at the same time. For Series 7252s configured with dual ranges between 10 (1 bar) and 1 000 psi (70 bar), the two test ports can be interconnected. The instrument will then auto range from the lowest to the highest sensor and vice versa. For performing single calibrations, this feature provides a high degree of performance over the full range. Increased throughput is also accomplished via the digital control valve technology, that ensures fast control speed with no overshoot. For example, each range will control in 10 % increments in 15 seconds, or less, into a 245 cubic centimeters (15 cubic inch) volume. No other controller combines this speed coupled with no overshoot control. For ease of use, the large, bright, active matrix color display provides the operator with menus that are presented in plain text with a logical navigation structure similar to all other Ruska digital pressure controllers and indicators, with multi-lingual support. Automating pressure test and calibration The Model 7252i and Model 7252 are easy to use and can automate your calibrations in several ways: Step up/down: For calibrations where the increments are fixed intervals, enter a user-defined step value. The Series 7252 increases or decreases the pressure by the step amount with the jog dial—no lengthy keystroke sequences to program. Sweep test: For simple exercising routines, as with dial gauges, enter a start value, a stop value and number of times to repeat the cycle. The Series 7252 will automatically exercise the device under test prior to the calibration run. Computer interface: Every Series 7252 is provided with both an RS-232 and IEEE-488 interface, and all Series 7252’s syntax follow SCPI protocol for easy programming. Intecal, an off-the-shelf software package, is available in addition to a LabVIEW® driver, a free download. Firmware updates can also be performed over the RS-232 interface (updates can be downloaded from the website). A MET/CAL driver is also an available option. Versatility to handle any pneumatic pressure calibration The Series 7252 is versatile enough to handle almost any type of pneumatic pressure calibration. Wide pressure range: The Series 7252 is available in a variety of full scale (FS) pressure ranges from 10 inH2O (25 mbar) to 2 500 psi (172 bar). Pressure units/scales: Select from over fifteen standard units of measure, including inHg at 0 °C and 60 °F, kPa, bar, psi, inH2O at 4 °C, 20 °C and 60 °F, kg/cm2, mmHg at 0 °C, cmHg at 0 °C, and cmH2O at 4 °C, and two user defined units. Head pressure: The Series 7252 automatically corrects for head pressure differences. Autovent and autozero: With a few keystrokes, the Series 7252 will vent the test port to atmosphere or automatically zero itself (autovent is not applicable to permanent absolute models). Protection of the device under test: Set upper and lower pressure limits to ensure protection of the device under test.


ВимірюванняГенерація (Імітація)


7252/7252i Pressure Controllers

- Pressure regulation up to 172 bar

- Control stability 0.001%

- Uncertainty up to 0.003%

- Two precision pressure modules

- Barometric reference (option)

- Protection overpressure for the DUT

Featured Products

P5543 Angle Adapter
To calibrate gauges with the pressure connection on the rear (for example, panel mount gauges) in their correct operating position, an angle adaptor should be used. The angle adapter uses the standard gauge adapters and positions the gauges...
Код: P5543
Laminar Flow Elements
Laminar Flow Elements
Laminar Flow Elements Flow measurement elements with highest accuracy EP Ehrler Prüftechnik manufactures LFEs in the flow range from 0.012 to 4000 m³/h. In addition to the standard range, EP offers customer-specific LFEs that are perf...
Код: LFE
2700G  Reference Pressure Gauge
2700G  Reference Pressure Gauge
The 2700G Reference Pressure Gauges provide best-in-class measurement performance in a rugged, easy-to-use, economical package. Improved measurement accuracy allows it to be used for a wide variety of applications. It is ideal for calibrati...
Код: 2700G
Water Activity Meter - AW-THERM
Water Activity Meter - AW-THERM
With AwTherm, Rotronic offers a professional, high-end laboratory unit for temperature-stabilized measurement of water activity. The wide control range permits measurements to be integrated directly in the tempered manufacturing or storage ...
Код: AW-THERM
Diagnostic Communication Tool for Michell Easidew and Pura
A comprehensive and self-contained tool to make routine service and maintenance of the Easidew and Pura ranges of dew-point transmitters simple to carry out. The Universal Communications Kit comprises: Electronic communications platform ...
Код: Tool
Miniature Fixed Resistor Model 836
Isotech produces a miniature resistor with ultra-low temperature coefficient and ultra-high stability. This is achieved because the resistors are oil filled and hermetically sealed. The function of hermetic sealing is to eliminate the ingre...
Код: 836
P5513 Pneumatic Comparator
P5513 Pneumatic Comparator
This pneumatic comparison pressure comparator is designed for testing pressure measuring instruments against master test instruments. This cost effective instrument provides precise control for important calibration requirements and includ...
Код: P5513
AII GPR-1200 MS-2 Premium Portable PPM Oxygen Analyzer
GPR-1200 MS-2 (ATEX) Designed for spot-checking ultra-high purity gases, the GPR-1200 MS-2 has a range of 0-1 ppm and LDL of 5 ppb O2 – the lowest oxygen measurements available with a portable instrument. ATEX-approved version available...
Код: GPR-1200
RPD Reference gas meters
RPD Reference gas meters The gold standard for low flow measurement The rotary piston gas meters GM16 meet the highest demands on the reliable and precise reference measurement of low flow up to 0.01 m³/h. You achieve an excellent mea...
Код: RPD-R
AII GPR-3500 MOVR Portable Purity Oxygen Analyzer
The GPR-3500 MOVR Portable Oxygen Purity Analyzer is the only electrochemical oxygen sensor based analyzer capable of measuring 100% oxygen on a continuous 24/7 basis for the purpose of verifying the purity of medical grade oxygen transport...
Код: GPR-3500
Hydra Model 798L
Hydra Model 798L
Precision calibration of thermometers calls for the use of stirred liquid calibration baths. The Hydra models set new standards in terms of price to performance ratio. Now Calibration Engineers and Metrologists can choose from a range of ba...
Код: 798L
3000AC voltage reference precision references and standards
The 3000AC provides laboratories with a fully traceable AC voltage source with accuracies in the order of 10ppm that can easily be verified with a DC voltage multimeter with accuracies in the 4ppm to 10ppm region. Using the latest in DAC te...
5.0000/5 2text_more_review
Код: 3000AC
Blackbody Source Model 989
Blackbody Source Model 989
Isotech first introduced the Model 988 to assist in relation to the SARS outbreak during the early 2000s. Used to increase the accuracy of thermal imagers being used to measure human skin temperature in temperature screening of applications...
5.0000/5 2text_more_review
Код: 989
ADT762(W) Automated Hydraulic Pressure Calibrator
ADT762(W) Automated Hydraulic Pressure Calibrator
The Additel 762 Automated Pressure Calibrator is unlike any other pressure calibrator on the market. This revolutionary product is a complete turnkey solution for automation of pressure calibration work up to 15,000 PSI. Designed for use i...
Код: ADT762(W)
Copper Point SPRT Model 108462
Copper Point SPRT Model 108462
The ITS-90 specifies the SPRT to the freezing point of silver, 961.78°C. Thermocouples can be used beyond this temperature but it is difficult to see small changes in temperature. For a Type R thermocouple the voltage sensitivity at the cop...
Код: 8462
Terminal Adapter Model 956
Terminal Adapter Model 956
Our TTI range use high quality ‘Lemo’ connectors for the Pt100 inputs. This simple accessory provides 4mm Terminal Posts for the connection of bare wires, spade terminals or 4mm plugs – useful if a lot of probes are going to be used with th...
4.5000/5 2text_more_review
Код: 956
DPS5000 Series  Digital Pressure Sensors
DPS5000 Series  Digital Pressure Sensors
The DPS5000 I2C from Druck, part of the UNIK5000 family, offers integrated digital electronics to enhance the performance level of the UNIK5000 Pressure Sensing Platform to levels unmatched by traditional analog sensors. It features an I2C ...
Код: DPS5000
I-Cal EASY
I-Cal EASY
Use I-Cal Easy to automate sensor calibration, enter up to 20 calibration points and let the software set the bath, wait for stability and log the data automatically. Choose the stability criteria and how many points to record at each calib...
Код: EASY
ATEX Humidity and Temperature Transmitter - Rotronic HF5-EX
ATEX Humidity and Temperature Transmitter - Rotronic HF5-EX
The Rotronic HygroFlex5-EX series consists of two-channel transmitters for the exact measurement of humidity and temperature in explosive atmospheres. This device conforms to the latest international standards. The robust aluminium HF5-EX h...
Код: HF5-EX
Model 944
Model 944
The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from the surface of the hot-plate causes a localised cold spot to be created which means that th...
Код: 944
Спасибо!