Qmin.: 0.01 m³/h to Qmax.: 16 m³/h
Measurement range: > 1:1000
Measurement accuracy(@atmospheric conditions, air) 0.5 % MV + 0.005 % FS
Pulse value: 77.000 imp/m³ / 153.000 imp/m³
HF pulse generator 1 piece / 2 piece
Medium: air, nitrogen, natural gas, helium, hydrogen, other non-flammable and non-aggressive gases
Connection DIN flange DN20 PN10
Installation length 130 mm
RPD Reference gas meters
The gold standard for low flow measurement
The rotary piston gas meters GM16 meet the highest demands on the reliable and precise reference measurement of low flow up to 0.01 m³/h. You achieve an excellent measuring accuracy of 0.5% MW + 0.005% EW. Both variants – with 1 or 2 HF pulse generators – are suitable for operation up to 6 bar overpressure. The new generation of reference gas meters is not only suitable for air, but also for hydrogen, natural gas and other non-flammable and non-aggressive gases. With the continuous, absolutely pulsation-free and highly precise flow measurement, the reference gas meters from Ehrler Prüftechnik are the gold standard in the field of low flow measurement – also for hydrogen.
Measuring principle
The reference gas meters GM16 operate according to the direct displacement principle (RPD -rotary positive displacement), in which two counter-rotating pistons convey a fixed volume from the inlet to the outlet of the gas meter with each full revolution. Due to the specially shaped pistons, an absolutely pulsation-free continuous operation can be realized (patent pending).
Applications
Industrial applications
Calibration & transfer standards
Measurement sections for test benches
Flow measurement of hydrogen
RPD Reference gas meters
- Qmin.: 0.01 m³/h to Qmax.: 16 m³/h
- Measurement range: > 1:1000
- Measurement accuracy 0.5 % MV
- Pulse value: 77.000 imp/m³ / 153.000 imp/m³
- HF pulse generator 1 piece / 2 piece