-Accuracy: < 2% of FS range under constant conditions

Ranges: 0-1, 0-10, 0-100, 0-1000 PPM, 0-1%, 0-25% Auto-ranging or manual lock on a single range

Application: Oxygen analysis in inert, helium, hydrogen, mixed and acid/ non-acid (CO2) gas streams

Area Classification: General purpose

Flow: Not flow sensitive or Sensitive; recommended flow rate 2 SCFH

Pressure: Inlet - regulate to 5-30 psig to deliver 1-2 SCFH flow; vent - atmospheric

Sensor Model: GPR non-acid (CO2) gas streams or XLT gases containing > 0.5% CO2

Power: Universal; specify 100/120/220/240 VAC or 12-28 VDC

Temp. Range: -10ºC to 45ºC (GPR), -20ºC to 45ºC (XLT sensor)

  • AII GPR-1900 Oxygen Analyzer With Remote Sensor
Brief specifications


More details

A panel mounted oxygen analyser with a remote sensor allows flexibility of installation. The GPR-1900 gas analyzer is suitable for trace oxygen measurements as low as 0-10 ppm; the GPR-2900 measures O2 up to 100%. The remote sensor block allows a very easy oxygen sensor replacement for simple and fast maintenance and low cost of ownership. All versions can be locked manually to a single range or auto-range. The user is always aware of the oxygen measurement range used via the range ID output.


ВимірюванняГенерація (Імітація)


AII GPR-1900 Oxygen Analyzer With Remote Sensor

-Accuracy: < 2% of FS range under constant conditions

Ranges: 0-1, 0-10, 0-100, 0-1000 PPM, 0-1%, 0-25% Auto-ranging or manual lock on a single range

Application: Oxygen analysis in inert, helium, hydrogen, mixed and acid/ non-acid (CO2) gas streams

Area Classification: General purpose

Flow: Not flow sensitive or Sensitive; recommended flow rate 2 SCFH

Pressure: Inlet - regulate to 5-30 psig to deliver 1-2 SCFH flow; vent - atmospheric

Sensor Model: GPR non-acid (CO2) gas streams or XLT gases containing > 0.5% CO2

Power: Universal; specify 100/120/220/240 VAC or 12-28 VDC

Temp. Range: -10ºC to 45ºC (GPR), -20ºC to 45ºC (XLT sensor)

Featured Products

AII GPR-18
The GPR-1800 series of intrinsically safe trace oxygen analyzers are designed for use in demanding process environments where the low detection limit down the AII’s industrial oxygen sensors can be well utilized. Typical for Analytical Indu...
Код: GPR-18
ITS-90 Optimal Fixed Point Cells
ITS-90 Optimal Fixed Point Cells
Isotech Ultra Pure-Metal Freezing Point Cells are designed specifically to realize the liquid-solid equilibrium temperatures of certain high-purity metal elements, for calibration of thermometers at the ITS-90 Fixed Points. When you purchas...
Код: ITS-90
Standard Thermocouple Model 1600 NCJ
Standard Thermocouple Model 1600 NCJ
The Isothermal range of Thermocouple Standards are the result of many years development. The type R and S standards will cover the range from 0°C to 1600°C. The measuring assembly comprises a 7mm x 300mm or 600mm gas tight 99.7% recrystalli...
4.5000/5 2text_more_review
Код:
QuickCal Blackbody
QuickCal Blackbody
When the high accuracy of the Gemini R is not necessary this product offers a cost effective solution for the calibration and testing of infrared thermometers. The QuickCal Blackbody is ideal for rapid and portable checking of infrared ther...
4.8182/5 11text_less_review
Код: QuickCal Blackbody
Automatic Humidity Probe Calibrator - Michell HG10
Automatic Humidity Probe Calibrator - Michell HG10
The Michell HG10 Humidity Calibration System is a computer-controlled automatic calibration system for humidity sensors. The HG10 is capable of repeatable generation of temperature and relative humidity set points over the range 1 to 95% RH...
Код: HG10
ADT912A  Low Pressure Test Pump
ADT912A  Low Pressure Test Pump
The ADT912A Pneumatic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 60 psi (4 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up...
Код: ADT912A
IO620-NPT A set of test point adaptors
IO620-NPT A set of test point adaptors
A set of test point adaptors to connect the tool less quick fit PV62XG, MC620G and the extension hoses to the device under test...
Код: IO620-NPT
ATEX Humidity and Temperature Transmitter - Rotronic HF5-EX
ATEX Humidity and Temperature Transmitter - Rotronic HF5-EX
The Rotronic HygroFlex5-EX series consists of two-channel transmitters for the exact measurement of humidity and temperature in explosive atmospheres. This device conforms to the latest international standards. The robust aluminium HF5-EX h...
Код: HF5-EX
Rotronic PC33 - Analog RH and Temperature Probe
The PC33 series offers a comprehensive range of relative humidity probes for accurate, stable and repeatable measurements. Available with analog output signals, the PC series can be installed in a wide variety of applications...
Код: PC33
ADT927 Hydraulic Pressure Test Pump
ADT927 Hydraulic Pressure Test Pump
The 927 Hydraulic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 85% vacuum to 10,000 psi (700bar). With the patented screw press technology, high pressures can be easily generated, as well as increas...
Код: ADT927
Portable Hygrometer - Michell Easidew Portable
Portable Hygrometer - Michell Easidew Portable
Simple to use and rugged, the Easidew portable hygrometer is the ideal tool for a wide range of on-site maintenance spot checks and dry dew-point online measurements. The robust integral sample system and wide measurement range ceramic meta...
Код: Easidew Portable
P5544 Two Gauge Stand
This adapter mounts directly to the test port of the calibrator and allows for the calibration of two instruments at the same time, or the connection of a reference test instrument. Maximum working pressure is 10,000 psi (700 bar)...
Код: P5544
microK Channel Expander
microK Channel Expander
The microsKanner can be used with any member of the microK family to add further channels, up to a maximum of 90 expansion channels. Easy to Use: The use of plug-and-play technology means that the extra channels appear automatically on your...
Код: microK
Fast-Cal Medium
Fast-Cal Medium
Fast-Cal – the product range you designed During early 2004 20 experienced engineers from many parts of the world were asked to produce their ideal specification for industrial calibration. Their top ten requirements, in order of priority, ...
5.0000/5 1text_less_review
Код: Medium
Handheld Water Activity Meter - Rotronic HygroPalm HP23-AW
Handheld Water Activity Meter - Rotronic HygroPalm HP23-AW
In many situations it can be very useful to measure water activity at goods-in, production or storage rooms, e.g. inspection of bulk materials to ensure they meet specifications...
Код: HP23-AW
Process Moisture Analyzer - Michell QMA601
Process Moisture Analyzer - Michell QMA601
The QMA601 Process Moisture Analyzer provides highly reliable, fast and accurate measurement of moisture content in a wide variety of carrier gases. It has a lower detection limit of 0.1 ppmV with reliable accuracy at sub-ppm trace moisture...
Код: QMA6010
8158 Advanced Digitising Multimeter advanced multimeter
The NEW 8158 Advanced Digitising Multimeter from Transmille has been designed as a modern replacement for aging multimeters without compromise. Capable of measurements at a rate of over 100,000 Samples per second, the 8158 8.5 Digit Multime...
4.2000/5 5text_lot_review
Код: 8158
Dew-Point Transmitter - Michell Easidew 34
The Easidew 34 is a dew-point transmitter with a 3/4” process connection. Designed for use in industrial conditions, it has a wide measurement range from -110 to + 20 °C dew point. Based on Ceramic Metal-Oxide Moisture Sensor the Easidew 3...
Код: Easidew 34
COMPASS® for Pressure Calibration Software
COMPASS® for Pressure Software Pressure Calibration Management Software COMPASS® for Pressure Calibration Software is a universal platform for all of your pressure calibration software needs. From piston gauges calibrating individual devi...
Код: COMPASS® for Pressure
Model 944
Model 944
The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from the surface of the hot-plate causes a localised cold spot to be created which means that th...
Код: 944