XGA301 Industrial Gas Analyzer
- Sensor choices from zirconia, galvanic electrochemical, infrared and ceramic impedance technologies
- Variable speed pump (optional)
- Zirconia sensor cleaning facility which can be operated at any time during use
- Intuitive HMI with back-lit display
- Two fully-programmable alarms
- 2 x voltage outputs and 2 x 4–20 mA outputs
- Digital RS232 output
- Software package includes live graphing and Excel™ compatible data-logging
- Password protection
Thermo-Paramagnetic Oxygen Analyzer - Michell XTP501
- Non-Depleting Rugged Paramagnetic Sensor
- Features
-
- Compact, lightweight and easy to install
- Intuitive user interface
- Tough IP55 housing
- Low cost of ownership due to minimal maintenance
- Measurement ranges from 0 to 1% up to 0 to 25% O2 and 20/80/90-100% O2
- Accuracy of better than ±1% full scale
- 2 x 4–20 mA outputs and MODBUS RTU over RS485 protocol as standard
Oxygen Combustion Control Analyzer - Michell XZR500
- Robust Long-Life MSRS Zirconia Sensor
- Features
-
- Measurement range: 0.01 to 25% O2
- Various probe for stack temperatures up to 1,300°C
- No air reference required with our Metallic Sealed Reference Sensor
- Long life zirconia cell with reliable accurate measurements
- Simple to maintain, easy to calibrate every 6 months
- Robust design that is simple to use
- Quick and easy to install
Oxygen Analyzer for Gas Purity Measurements - Michell XZR400
- Fast Responding With Metallic Sealed Reference Sensor
- Features
-
- Fast response time
- Simple and easy operation
- Low maintenance and cost of ownership
- No need for reference air
- Barometric pressure compensation
- Multiple Outputs available from 4-20 mA, RS485 Modbus RTU and RS232
- Rack, wall-mount, bench-mount, and transportable versions available
- Optional built-in Easidew Transmitter with rack-mount version
Oxygen Analyzer - Michell XTP601
- Low Maintenance O2 Measurement
- Features
-
- General purpose or ATEX, IECEx, CCSAUS, TC, TR & Ex hazardous area certified models
- Meets the requirements of IEC61508 SIL 2
- Ranges available: 0–0.5% up to 0–50% & 20, 80 or 90–100%
- Touch-screen display allows calibration or adjustment without the need for a hot works permit
- Intrinsic error (accuracy) is better than 1% full scale
- Zero span stability better than 0.25% of span per month
- Outputs include RS485 and two 4-20mA (following NAMUR NE 44 standard)
- Low cost of ownership due to minimal maintenance and no consumable parts
Michell XTC501 Thermal Conductivity Analyser
- Hydrogen, Binary Gas and Gas Mixtures Measurement
- Features
-
- Compact, lightweight and easy to install
- Intuitive user interface
- Tough IP55 housing
- Low cost of ownership due to minimal maintenance
- Measurement ranges from 0 to 5% up to 0 to 100% and 50/80/90 to 100%
- Accuracy of better than ±1% full scale
- 2 x 4–20 mA outputs and MODBUS RTU over RS485 protocol as standard
-Features of Fixed Ambient Oxygen Deficiency Monitors with Alarms
Low maintenance with typically 32 months oxygen sensor life
Audible and visual oxygen deficiency alarm available
Up to four measurement ranges
Accuracy of <2% of span
Mains power with battery back-up (GPR-35)
Remote oxygen sensor & pump options (GPR-35)
Analog output for connection to DCS
12-28 V DC operation (GPR-2500 versions)
Cost-Effective Oxygen Analyser for Combustion - OXY-FLEX Series
- Long-Life, Non-Depleting Oxygen Measurement
- Features
-
- Configurable outputs: 4-20 mA and 0 to 10 V DC or RS232 comms interface
- Cycling 3.3 V DC logic output allows direct monitoring of the O2 sensor for diagnostic purposes
- Can be calibrated in normal air (20.7% O2) or in any other known O2 concentration
- Selectable output filtering allows fast and dynamic or slow and stable output
- Externally triggered automatic or manual calibration
- Diecast aluminium case IP65 with stainless steel probe
- Sample temperature up to +400°C
Binary Gas Analyzer for Hydrogen Monitoring - Michell XTC601
- Thermal Conductivity Technology in Safe or Hazardous Areas
- Features
-
- Suitable for use in ATEX, IECEx, TC TR Ex & CCSAUS certified Hazardous Areas
- Optional status LED’s following NAMUR standard
- Compact and rugged design with an EExd enclosure and 4-20 mA output
- Touch-screen display allows calibration or adjustment without the need for a hot works permit
- Accuracy of better than ±2% full scale
- IP66 rated enclosure
- Low cost of ownership due to minimal maintenance
- Typical ranges available: 0-5% up to 0-100% (others gas dependent)
- Stability ±0.5% per month (of span)
-Accuracy: 2% of FS range under constant conditions
Analysis: 0-20, 0-50, 0-100 PPM FS ranges; Auto-ranging or manually lock on single range
Application: Trace H2S in flowing gas streams
Area Classification: Certified for use in hazardous areas - see lower right
Enclosure: NEMA Type 3R for rain in outdoor applications (UL) NEMA 4X (ATEX)
Flow: Maintain constant flow of Sample and Air at 1 SCFH; maintain Sample to Air ratio of 1:1
Pressure: Inlet - regulate to 5-30 psig to deliver constant 1 SCFH flow; vent – atmospheric
Power: 12-28 VDC Transmitter, 12 VDC Pump; 12-28 VDC (UL or ATEX Certified) 110-220 VAC (ATEX Certified) Transmitter, 12-24 VDC PUMP
Sample System: Coalescing filter, flow meters, sample/span valve; Flow through SS sensor housing, flow control valve, sample flow meter, 3-way sample/span valve, air pump, air flow meter
Sensor Model: OSV-72-7HH (standard ranges)/ OSV-72-7HH-LD (standard ranges)
Temp. Range: -10 ºC to 45ºC
AII GPR-7100 Portable PPM H2S Analyzer
-Accuracy: < 2% of FS range under constant conditions
Analysis: 0-20, 0-50, 0-100 PPM FS ranges; auto-ranging or manually lock on single range
Application: Trace PPM H2S in flowing gas streams
Area Classification: Meets intrinsic safety standards for use in Class 1, Division 1, Group C, D hazardous areas
Flow Sensitivity: Maintain constant flow; air 1 SCFH, sample 1 SCFH
Pressure: Inlet - regulate to 5-30 psig to deliver constant 1 SCFH sample flow rate; vent – atmospheric
Power: Rechargeable battery, 8 hours day duty cycle
Sample System: Coalescing filter and flow meters; Air to sample gas flow ratio 1:1 SCFH
Sensor Model: OSV-72-7HH (standard ranges)
Temp. Range: -10 ºC to 45 ºC
AII GPR-3500 MOVR Portable Purity Oxygen Analyzer
-Accuracy: < 2% at constant conditions
Analysis Ranges: 0-100% Auto-ranging or manual lock on a single range
Application: Continuous monitoring of oxygen levels up to 100% O2
Not flow sensitive
Power: Rechargeable battery, 60 day cycle, 8 hrs with pump
Sensor Model: GPR-11-120-OP
Temp. Range: -10ºC to 45ºC
Area Classification: General purpose only
AII GPR-3500 MO Portable Oxygen PurityAnalyzer
-Accuracy: < 2% of FS range under constant conditions, e.g. constant temperature, flow rate and ambient pressure
Analysis: 0-100% FS range
Application: Intermittent monitoring of oxygen levels up to 100% O2
Area Classification: General purpose
Not flow sensitive
Pressure: Inlet - regulate to 5-30 psig to deliver 1-2 SCFH flow;
vent - atmospheric
Power: Rechargeable battery, 60 day cycle
Sample System: Flow indicator & control valve
Sensitivity: < 0.5% of FS range
Sensor Model: GPR-11-120-RTS
Operating Range: 5ºC to 45ºC
AII GPR-35 Ambient Oxygen Monitors
-Accuracy: < 2% of reading under constant conditions
Analysis: 0-25% FS ranges
Application: Monitor oxygen content of ambient atmospheres or confined spaces where oxygen depletion is a concern
Area Classification: General purpose (Category, II; pollution degree, 2)
Flow: Sampling - not applicable to ambient monitoring
Power: 100/110/220/240 VAC with fluctuation not to exceed +10%; battery back-up on trickle charge; battery life 30 days normal mode or 8 hours in alarm mode
Operating Range: 0º to 45ºC
Alarms: Two adjustable SPDT Form C non-latching relay contacts, preset to OHSA 20.0% Caution, 19.5% Danger settings
AII GPR-3100 Oxygen Purity Analyzer
-Accuracy: < 2% of FS range under constant conditions, e.g. constant temperature, flow rate and ambient pressure: +5% with temperature fluctuation of +10°F
Accuracy: < 1% of FS range at constant conditions; inherent accuracy of 0.1% following calibration with 95-100% oxygen
Analysis: 90-100%, 80-100%, 50-100% and 0-100% or 0-5%, 0-10%, 0-25% and 0-100%; Auto-ranging or fixed single range
Application: Continuous analysis of high purity oxygen concentrations up to 100% oxygen in inert, He, H2 and mixed gases
Area Classification: General purpose
Connections: Compression tube fittings 1/4" inlet, 1/4” vent or Compression tube fittings 1/8" inlet, 1/4” vent
Not flow sensitive
Pressure: Inlet - regulate to 5-30 psig to deliver 2 SCFH flow; vent – atmospheric
Power: Universal; specify 100/110 or 200/220 VAC for heater system
Sensitivity: < 0.1% oxygen
Temp. Range: 5ºC to 45ºC
AII GPR-2900 Oxygen Analyzer With Remote Sensor
-Accuracy: < 2% of FS range under constant conditions
Analysis: 0-1%, 0-5%, 0-10%, 0-25% FS ranges; optional 0-1%, 0-5%, 0-10%, 0-100% FS ranges: auto-ranging or fixed single range
Application: Oxygen analysis in inert, helium, hydrogen, mixed and acid (CO2) gas streams
Area Classification: General purpose
Flow: Not flow sensitive
Pressure: Inlet - regulate to 5-30 psig to deliver 1-2 SCFH flow; vent – atmospheric
Power: Universal; specify 100/120/220/240 VAC or 12-28 VDC
Sensor Model: non-acid (CO2) gas streams or gases containing > 0.5% CO2
Temp. Range: 5ºC to 45ºC (GPR sensor); -10ºC to 45ºC (XLT sensor)
AII GPR-2800 Process Oxygen Analyzers
-Accuracy: < 2% of FS range under constant conditions
Analysis: 0-1%, 0-5%, 0-10%, 0-25% FS ranges; auto-ranging or fixed single range or 0-25% O2 FS ranges
Application: Oxygen analysis in hazardous ambient areas and confined spaces
Area Classification: Certified for use in hazardous areas
Connections: 1/8" or 1/4" compression tube fittings
Enclosure: NEMA Type 3R for rain in outdoor applications (UL) NEMA 4X (ATEX)
Flow: Not flow sensitive
Pressure: Inlet - regulate to 5-30 psig to deliver 1-2 SCFH flow; vent – atmospheric or Atmospheric
Power: 18-24 VDC or 12-28 VDC (UL, ATEX Certified), 110-220 VAC (ATEX Certified)
Sensor Model: GPR for non-acid (CO2) gas streams; XLT for gases containing > 0.5% CO2
Operating Range: 5ºC to 45ºC (GPR sensor); -10º to 45ºC (XLT); -10ºC to 45ºC (GPR sensor)
-Accuracy: < 2% of FS range under constant conditions
Analysis: 0-1%, 0-5%, 0-10%, 0-25% FS ranges Auto-ranging or manual lock on a single range
Application: Oxygen analysis in inert, helium, hydrogen, mixed and acid (CO2) gas streams
Area Classification: General purpose
Flow: Not flow sensitive
Pressure: Inlet - regulate to 5-30 psig to deliver 2 SCFH flow; vent – atmospheric
Power: Universal; specify 100 or 200 VAC for heater system
Sensor Model: GPR sensor for non-acid (CO2) gas streams and XLT sensor for gas mixture with > 0.5% CO2
Temp. Range: 5ºC to 45ºC (GPR sensor), -10°C to 45° (XLT sensor)
Remote Communication via USB, RS232, RS485
AII GPR-2500 Percent Oxygen Analyzer
-Accuracy: < 2% of FS range under constant conditions
Analysis: 0-1%, 0-5%, 0-10%, 0-25% FS ranges; auto-ranging or fixed single range
Application: Oxygen analysis in inert, hydrocarbon, helium, hydrogen, mixed and acid (CO2) gas streams
Area Classification: General purpose or Certified for use in hazardous areas
Connections: 1/8" compression tube fittings
Enclosure: Fiberglass NEMA 4X; NEMA Type 3R for rain in outdoor applications (UL) NEMA 4X (ATEX) or Painted aluminum
Flow Sensitivity: Not flow sensitive, 1-2 SCFH recommended
Pressure: Inlet - regulate to 5-30 psig to deliver 1-2 SCFH flow; vent - atmospheric
Power: 18-24 VDC (2 Wire Loop)
Sample System: None or Sample flow meter; options available, see other side
Sensor Model: GPR-11-32-4 for non-acid (CO2) gas streams XLT-11-24-4 for gases containing > 0.5% CO2
Operating Range: 5ºC to 45ºC (GPR sensor), -10º to 45ºC (XLT sensor)
AII GPR-2000 Portable Oxygen Analyzer
-Accuracy: < 2% of FS range under constant conditions
Analysis Ranges: 0-1%, 0-5%, 0-10%, 0-25% FS Auto-ranging or manual lock on a single range
Application: Oxygen analysis in inert, helium, hydrogen, mixed and acid (CO2) gas streams
Area Classification: General purpose or Class I, Division 1, Groups C, D (Certified for use hazardous areas)
Not flow sensitive
Pressure: Inlet - regulate to 5-30 psig to deliver 2 SCFH flow;
vent – atmospheric
Power: Rechargeable battery, 60 day cycle, 8 hrs with pump
Sample System: None; optional integral sample pump and panel mounted flow meter and/or coalescing filter
Sensitivity: < 0.5% of FS range
Sensor Model: GPR for non-acid (CO2) gas streams, XLT for gas mixture with > 0.5% CO2
Temp. Range: 5º to 45ºC (GPR sensor), -10º to 45ºC (XLT sensor)
Wetted Parts: Brass, plastic or Stainless steel flow housing, tubing and fittings
AII GPR-1900 Oxygen Analyzer With Remote Sensor
-Accuracy: < 2% of FS range under constant conditions
Ranges: 0-1, 0-10, 0-100, 0-1000 PPM, 0-1%, 0-25% Auto-ranging or manual lock on a single range
Application: Oxygen analysis in inert, helium, hydrogen, mixed and acid/ non-acid (CO2) gas streams
Area Classification: General purpose
Flow: Not flow sensitive or Sensitive; recommended flow rate 2 SCFH
Pressure: Inlet - regulate to 5-30 psig to deliver 1-2 SCFH flow; vent - atmospheric
Sensor Model: GPR non-acid (CO2) gas streams or XLT gases containing > 0.5% CO2
Power: Universal; specify 100/120/220/240 VAC or 12-28 VDC
Temp. Range: -10ºC to 45ºC (GPR), -20ºC to 45ºC (XLT sensor)
AII GPR-1800 PPM Oxygen Analyzer
-Accuracy: < 2% of FS range under constant conditions
Analysis: 0-10, 0-100, 0-1000 PPM, 0-1%, 0-25% (CAL) FS Auto-ranging or manual lock on a single range
Application: Oxygen analysis in inert, hydrocarbon, helium, hydrogen, mixed and acid (CO2) gas streams
Area Classification: Certified for use in hazardous areas
Connections: 1/8" compression tube fittings
Enclosure: NEMA Type 3R suitable for rain in outdoor applications (UL); NEMA 4X (ATEX)
Flow: Not flow sensitive; recommended flow rate 1-2 SCFH
Pressure: Inlet - regulate to 5-30 psig to deliver 1-2 SCFH flow; vent - atmospheric
Power: 12-28 VDC (ULc and ATEX Certified); 110-220 VAC (ATEX Certified); 18-24 VDC
Sample System: Sample flow meter; Unique liquid drain sensor manifold, flow indicator; options available, see other side
Sensor Model: GPR-12-333-LD for non-acid (CO2) gas streams; XLT-12-333-LD for gases containing > 0.5% CO2; XLT-12-333 for gases containing > 0.5% CO2
Operating Range: 5ºC to 45ºC (GPR sensor); -10ºC to 45ºC (GPR sensor); -10º to 45ºC (XLT sensor)
-Features of Trace Oxygen Analyzer for Process Industries
Four measurement ranges provided
LDL of 50 ppb
Measures in CO2 with XLT sensor
Sensor life of up to 24 months
Simple, intuitive HMI
Barometric pressure and temperature compensation
Two user configurable alarms
Optional Modbus
Range of sampling options available

-350x280.jpg)
-350x280.jpg)





-350x280.jpeg)