AII GPR-7500 PPM H2S Analyzer

-Accuracy: 2% of FS range under constant conditions

Analysis: 0-20, 0-50, 0-100 PPM FS ranges; Auto-ranging or manually lock on single range

Application: Trace H2S in flowing gas streams

Area Classification: Certified for use in hazardous areas - see lower right

Enclosure: NEMA Type 3R for rain in outdoor applications (UL) NEMA 4X (ATEX)

Flow: Maintain constant flow of Sample and Air at 1 SCFH; maintain Sample to Air ratio of 1:1

Pressure: Inlet - regulate to 5-30 psig to deliver constant 1 SCFH flow; vent – atmospheric

Power: 12-28 VDC Transmitter, 12 VDC Pump; 12-28 VDC (UL or ATEX Certified) 110-220 VAC (ATEX Certified) Transmitter, 12-24 VDC PUMP

Sample System: Coalescing filter, flow meters, sample/span valve; Flow through SS sensor housing, flow control valve, sample flow meter, 3-way sample/span valve, air pump, air flow meter

Sensor Model: OSV-72-7HH (standard ranges)/ OSV-72-7HH-LD (standard ranges)

Temp. Range: -10 ºC to 45ºC

Brief specifications


More details

The GPR-7500 analyzer utilizes the low-power electro-chemical sensor technology to provide a cost-effective and easy to maintain online-installation hydrogen sulfide measurement in a small package. The GPR-7100 is a portable H2S analyzer version preferably used for spot checking the process or temporary usage during servicing or commissioning of a permanent installation gas analyzer. These advanced instruments from AII are agency approved for use in flammable gas streams.


ВимірюванняГенерація (Імітація)


AII GPR-7500 PPM H2S Analyzer

-Accuracy: 2% of FS range under constant conditions

Analysis: 0-20, 0-50, 0-100 PPM FS ranges; Auto-ranging or manually lock on single range

Application: Trace H2S in flowing gas streams

Area Classification: Certified for use in hazardous areas - see lower right

Enclosure: NEMA Type 3R for rain in outdoor applications (UL) NEMA 4X (ATEX)

Flow: Maintain constant flow of Sample and Air at 1 SCFH; maintain Sample to Air ratio of 1:1

Pressure: Inlet - regulate to 5-30 psig to deliver constant 1 SCFH flow; vent – atmospheric

Power: 12-28 VDC Transmitter, 12 VDC Pump; 12-28 VDC (UL or ATEX Certified) 110-220 VAC (ATEX Certified) Transmitter, 12-24 VDC PUMP

Sample System: Coalescing filter, flow meters, sample/span valve; Flow through SS sensor housing, flow control valve, sample flow meter, 3-way sample/span valve, air pump, air flow meter

Sensor Model: OSV-72-7HH (standard ranges)/ OSV-72-7HH-LD (standard ranges)

Temp. Range: -10 ºC to 45ºC

Featured Products

Oberon R Model 426
Oberon R Model 426
The Oberon R uses a Sodium heat Pipe to ensure an exceptionally low temperature gradient along the furnace core. It is ideal for the realization of Aluminium, Silver or Copper ITS-90 Fixed Points. It may be used as a blackbody source over t...
Код: 427
LMF – System for high precision flow measurement of gas and air
LMF – System for high precision flow measurement of gas and air
LMF® – LaminarMasterFlow® High-precision flow measurement of gas and air The EP LMF® – LaminarMasterFlow® is a complete system for high precision flow measurement of gas and air (volume and mass flow). The LMF® system consists of a fl...
Код: LMF
Local Evaluation Unit OPS
Local Evaluation Unit OPS
The Local Evaluation Unit OPS is a local microcomputer designed for comparison of reference impulses coming from the standard meter with optical impulses or reflexes from the black mark on the disk of the meter. Value of the measured error ...
Код: Unit OPS
Dryers for Humidity Calibration Systems - PSD2 and PSD4
Pressure Swing dryers provide a source of very dry compressed air for use as a zero gas in humidity calibration systems, or for general laboratory applications. The Michell PSD Series Pressure Swing Dryers use two columns filled with 4Å mo...
Код: PSD2,4
Gallium Fixed Point Apparatus
Gallium Fixed Point Apparatus
Model 17402B Gallium Apparatus is not an adaptation from general purpose equipment, but is designed specifically to realize and maintain the Gallium Cell on the melt plateau, for calibration of thermometers on the International Temperature ...
Код:
Flow generator
Flow generator Simulating breathing air flows for the calibration of flow sensors (air) The test bench is used to calibrate air flow sensors for lung function diagnostics and is designed for simulating the human breathing air. By usin...
Код: FG
Rotronic PC52 - Analog RH and Temperature Probe
The PC52 series offers a comprehensive range of relative humidity probes for accurate, stable and repeatable measurements. Available with analogue output signals, the PC series can be installed in a wide variety of applications...
Код: PC52
4857 Gemini 700
4857 Gemini 700
Need advice on which model? Dry Block Selection Guide The Gemini range of Dry Blocks have high capacity allowing a large number of probes to be calibrated together. They are also suitable to accept large diameter probes with the block volum...
5.0000/5 1text_less_review
Код: 4858
9334A SERIES of Resistance Standards
9334A SERIES of Resistance Standards
GUILDLINE INSTRUMENTS 9334A SERIES of Resistance Standards are designed as very stable laboratory standards for high accuracy resistance calibration in air, without the need for a temperature controlled bath. PRODUCT FEATURES 12 Month Stabi...
Код: 9334A
AII GPR-1100 Portable PPM Oxygen Analyzer
Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in the...
Код: GPR-1100
Model 471 Simple Argon Apparatus
Model 471 Simple Argon Apparatus
The Isotech Argon Triple Point Apparatus is a robust, simple to use and affordable solution for the realisation of the argon triple point. Many laboratories use liquid nitrogen comparators which are convenient and can be low cost but the ni...
3.5000/5 6text_lot_review
Код: 471
7050/7050i Pressure Indicators
7050/7050i Pressure Indicators
The Series 7050 digital pressure indicator expands upon the popular line of Series 7000 products such as the Series 7250 digital pressure controller and Series 7252 dual output pressure controller. The 7050 provides an instrument for applic...
Код: 7050, 7050i
Dew-Point Hygrometer - Michell SF82 Online
Dew-Point Hygrometer - Michell SF82 Online
The SF82 Online has been developed as a fast-response, quick-to-install hygrometer system for the complete dew-point measurement range of -60 up to +60 °C dew point, which covers many moisture measurement applications...
Код: SF82 Online
GB Gas Booster
GB Gas Booster
GB-75 and GB-152 are gas boosters with control kits intended to be used to provide a very high pressure gas supply to systems using a Fluke Calibration GPC1 High Pressure Gas Controller and other high gas pressure test and calibration syste...
Код: GB Gas Booster
Isotech Model 670 SPRT
Isotech Model 670 SPRT
The 670SQ is our latest thermometer, to be specifically designed to give optimum performance up to the aluminium point. Its construction permits the four internal platinum lead wires to expand and contract in the same manner as those of sil...
Код: 670
Meteorology RH and T Probes - Rotronic MP100A/MP400A
The MP100A is a combined humidity and temperature probe designed primarily for meteorological and general outdoor applications. Operation from DC voltage and low power consumption make the MP101A particularly suitable for operation at remot...
Код: MP100A/MP400A
Hydra Model 798H
Hydra Model 798H
Precision calibration of thermometers calls for the use of stirred liquid calibration baths. The Hydra models set new standards in terms of price to performance ratio. Now Calibration Engineers and Metrologists can choose from a range of ba...
Код: 798H
Simple Nitrogen Boiling Point Apparatus Model 461
Simple Nitrogen Boiling Point Apparatus Model 461
This model is a lower cost alternative to the ITL M 18205. This model is a simple apparatus open to the atmosphere comprising a stainless steel dewar flask filled with liquid Nitrogen, an insulating layer which houses a metallic equalising ...
Код: 461
Gas Flow Model 984
The higher temperature Isotech Blackbody Fixed Point Cells consist of high purity metals within a graphite body. Graphite reacts with air to form Carbon Dioxide. The rate of the reaction is temperature dependant. The effect is small at low ...
2.0000/5 1text_less_review
Код: 984
Moisture in Natural Gas Analyzer - Michell OptiPEAK TDL600
Moisture in Natural Gas Analyzer - Michell OptiPEAK TDL600
The next generation TDLAS Analyzer for automatic online measurement of moisture in variable compositions of natural gas and biomethane. The OptiPEAK TDL600 Tuneable Diode Laser Analyzer employs the latest techniques in laser absorption spec...
Код: TDL600