Oberon R Model 426

- 450°C to 1100°C

- Model 426 is for Aluminium, Silver or Copper slim fixed point cells as well as for comparison calibration. Heatpipes provide the ideal conditions for the creation and maintenance of slim ITS-90 cells.

- 50 x 300mm Calibration Volume

- Compact Heatpipe Furnace

- Suits Aluminium, Silver or Copper Fixed Points

- Can be used for comparison and infrared calibration

Brief specifications


More details

The Oberon R uses a Sodium heat Pipe to ensure an exceptionally low temperature gradient along the furnace core. It is ideal for the realization of Aluminium, Silver or Copper ITS-90 Fixed Points. It may be used as a blackbody source over the range 450°C to 1090°C. The furnace heater is of the non-inductive bird-cage design insulated by twin bore alumina tubes. The heat pipe is designed so that the inner wall is not subject to thermal expansion stresses from the outer wall before the heat pipe reaches conduction temperature. The working fluid is permanently and safely sealed within the plasma-arc welded enclosure.


ВимірюванняГенерація (Імітація)


Oberon R Model 426

- 450°C to 1100°C

- Model 426 is for Aluminium, Silver or Copper slim fixed point cells as well as for comparison calibration. Heatpipes provide the ideal conditions for the creation and maintenance of slim ITS-90 cells.

- 50 x 300mm Calibration Volume

- Compact Heatpipe Furnace

- Suits Aluminium, Silver or Copper Fixed Points

- Can be used for comparison and infrared calibration

Featured Products

Isotech Model 909 SPRT
This economically-priced Standard Platinum Resistance Thermometer, Model 909, is the workhorse of calibration laboratories all over the world. During 2007 we reviewed our range of SPRTs and now have new models in the 909 family, the 909L an...
3.6316/5 19text_lot_review
Код:
AII GPR-7500 PPM H2S Analyzer
AII GPR-7500 PPM H2S Analyzer
The GPR-7500 analyzer utilizes the low-power electro-chemical sensor technology to provide a cost-effective and easy to maintain online-installation hydrogen sulfide measurement in a small package. The GPR-7100 is a portable H2S analyzer ve...
Код: GPR-7500
4Sight2 Calibration Software
4Sight2 Calibration Software
4Sight2 Calibration software is a web-based calibration management tool that helps you maintain and control your calibration environment to the highest metrology standards. 4Sight2 from Druck, a Baker Hughes business, offers easy-to-use, co...
Код: 4Sight2
PROEDIT procedure builder and editor
PROEDIT procedure builder and editor
ProEdit is included in the ProCal suite of programs, and can be run independently of ProCal. This allows procedures to be edited on computers that are currently not in use to avoid interfering with laboratory workflow and without requiring ...
Код: PROEDIT
Process Sampling System - Michell ES70
Moisture analyzers are only as reliable as the sample extraction, handling and conditioning techniques used. The ES70 Sampling System range offers a set of configuration options to cover all process moisture and dew-point application needs,...
Код: ES70
Jarrett-Isotech Water Triple Point Cells
Jarrett-Isotech Water Triple Point Cells
The Water Triple Point is the most important fixed point, the only point common to the ITS-90 and the Thermodynamic Temperature Scale. It is an essential reference point for every temperature laboratory. The Jarrett-Isotech cells are the be...
Код: Jarrett
TRUrac Model 847
TRUrac Model 847
Thermocouple Reference System The TRUrac is a 0°C or elevated temperature thermocouple reference system mounted in a 19” chassis. It has been developed for situations where ambient temperature can be up to 65°C. The reference temperature is...
Код: 847
Oceanus-6
Oceanus-6
The Oceanus-6 PLUS has all the advantages of the Isocal-6 models but with a substantially larger calibration volume, 50mm diameter by 300mm deep. The Oceanus-6 can be used as a Dry Block, a Liquid Bath, a Blackbody Source for infrared therm...
Код: Oceanus-6
7810 WIDEBAND TRANSCONDUCTANCE AMPLIFIER
7810 WIDEBAND TRANSCONDUCTANCE AMPLIFIER
GUILDLINE INSTRUMENTS 7810 WIDEBAND TRANSCONDUCTANCE AMPLIFIER is the latest innovation for High Current, Wide Bandwidth AC Outputs. PRODUCT FEATURES 50 A and 100 A Models Calibrated Frequency Range (DC to 100 kHz) Uncalibrated 100 kHz to 2...
Код: 7810
Blackbody ITS-90 Fixed Points
Blackbody ITS-90 Fixed Points
Primary Standard cells fit into the Medusa and Oberon, covering from Indium to Copper Points. These cylindrical cells are 42mm diameter and have a cavity 9mm diameter x 87mm deep. The Medium Temperature “Hockey Puck” cells are 64mm diameter...
Код:
Parallel Tube Liquid Bath Model 915H
Parallel Tube Liquid Bath Model 915H
The Isotech Model 915 Liquid Bath is suitable has a wide temperature range, using silicon oils and other suitable liquids. All components in contact with the liquid are of stainless steel, and are insulated with materials which are complete...
Код: 915H
787 Model
787 Model
The Model 787 calibrator redefines industry standards by blending industry leading performance and speed of operation within a robust design tailored for extreme conditions. The maximum operating temperature is 660°C allowing wide range of ...
Код: 786
RPM4 Reference Pressure Monitor
RPM4 Reference Pressure Monitor
RPM4 is much more than a traditional pressure indicator State of the art performance from very low pressure to 280 MPa (40 000 psi)… advanced on-board features…compact and rugged…full local and remote communications…RPM4 is the perfect sol...
Код: RPM4
7330 Series of Oil Based Resistance Standards
7330 Series of Oil Based Resistance Standards
Guildline Instruments 7330 Series of Oil Based Resistance Standards are designed for high accuracy resistance calibration in oil (Fluid Baths) or in air. PRODUCT FEATURES Typical AC/DC Error ...
Код: 7330
OEM Transmitter Temperature and Humidity - Rotronic XB32A
OEM Transmitter Temperature and Humidity - Rotronic XB32A
The XB32A OEM transmitter consists of a cable probe and PCB without housing. Thanks to its compact size, high accuracy and various selection possibilities, the transmitter can be adapted to customer wishes and used practically everywhere...
Код: XB32A
Parallel Tube Liquid Bath Libra Model 785M
Parallel Tube Liquid Bath Libra Model 785M
Isotech calibration baths employ sophisticated designs to ensure calibration to the smallest of uncertainties. In 1986 Isotech purchased the interests of H N Irving & Sons Temperature division which had specialised in providing high quality...
Код: 785M
6664C LOW THERMAL QUAD CHANNEL SCANNERS
6664C LOW THERMAL QUAD CHANNEL SCANNERS
THE 6664C LOW THERMAL QUAD CHANNEL SCANNERS ENABLES SOFTWARE CONTROLLED, FULLY AUTOMATED NORMAL AND HIGH OHM MEASUREMENTS WITH VOLTAGES UP TO 1000 V PRODUCT FEATURES Withstands up to 1000 Vdc to provide fully automated resistance measuremen...
Код: 6664C
Dew-Point Hygrometer - Easidew Advanced Online
Dew-Point Hygrometer - Easidew Advanced Online
Код: Easidew Advanced Online
Quick Cal Low
Quick Cal Low
Isotech’s Quick Cal range of testers are ideally suited to the less exacting applications where our larger, better specified baths are unnecessary. The Low Temperature Quick Cal covers the temperature range of -12°C to +140°C, making it ide...
Код: Quick Cal Low
IO620-MET A set of test point adaptors
IO620-MET A set of test point adaptors
A set of test point adaptors to connect the tool less quick fit PV62XG, MC620G and the extension hoses to the device under test...