Categories
-
Pressure
-
Temperature
-
Humidity
-
Electrical signals
- Calibrator of electrical signals
- Reference multimeters
- Voltage, resistance, frequency standards
- Precision bridges
- Teraohmmeter
- Reference electricity meters
- Installations for verification of electricity meters
- Power analyzers
- Voltage dividers
- Current shunts
- Precision current transformers
- Systems for measuring current
- Precision measuring systems
- Test Equipment
- Liquid and air baths for resistance measures
- Standards of conductivity (salinity)
- Software
- Accessories
- Multifunction calibrators
-
Flow measurement
-
Chemical composition
-
Complex solutions
-
Services
RH and Temperature Probe Calibrator - Rotronic HygroGen 2
-Control probe specification ±0.8 %RH (10…30 °C), ±2 %RH (0…60 °C) ±0.1K (10…30 °C), ±0.3K (0…60 °C)
Working volume: 1.5 litres 17 litres
Typical calibration uncertainty: ±1.5 %RH (k=2) at 23 °C, ±0.15 °C (k=2) 15...50 °C
Sensor: HygroClip2, capacitive RH sensor, Pt100 temperature sensor
Generation method Mixed flow with desiccant drier cell and piezoelectric humidifier; Peltier thermoelectric element with radial chamber mixing fan
Precision Dew-Point Hygrometer - Michell S4000 TRS
- For Very Low Dew-Point Measurement in Laboratories
- Features
-
- 0.1°Cdp accuracy
- Measurement range: -100 to +20°Cdp
- Precision 100 Ω 4 wire platinum resistance thermometer
- Dual optics detection system
- Available with VCR couplings for optimum trace moisture sampling
- Dual multi-function LED display with unit indicator
Humidity Validator - Michell HygroCal100
- Automated Humidity Probe Validation
- Features
-
- Truly portable at 3.2kg, and completely self-contained
- Intuitive UI makes automating probe verification simple
- Integral battery pack means validation can be done without access to services
- Validate 7 probes simultaneously
- Automated validation procedures for complete hands-off probe verification
- Internal calibration correction cycle ensures continued confidence
- Optional chilled mirror reference hygrometer, allowing use as a calibrator
- Download logged verification data direct to USB memory
Humidity and Temperature Probe Calibrator - Michell OptiCal
- Built-in Chilled Mirror Reference Hygrometer
- Features
-
- Simple operation and maintenance
- Easy calibration of relative humidity sensors
- Excellent chamber stability and uniformity
- Manual control or optional straightforward automated set point programming
- Humidity and temperature-controlled chamber
- Generate 10 to 90% RH over +10 to +50°C temperature
- Built in precision chilled mirror reference instrument
- Transportable to allow on-site calibrations
Dryers for Humidity Calibration Systems - PSD2 and PSD4
- Pressure Swing Drying Principle for Continuous Operation
- Features
-
- Excellent long-term stability
- Maintenance free except for a desiccant change once every 5 years
- Completely self-contained
- Low power consumption
DG2, DG3, DG4 and VDS3 - Michell Dew-Point Generators
- Full Suite of Moisture Generators for Laboratory Applications
- Features
-
- Manual selection, push button or computer control of generated dew point
- 100 to +20°C dew-point range capability, depending on model
- Precision flowmeter or mass flow controller operation
- High stability and repeatability
- Fast response to changes in set-point
Dew-Point Calibration System - Michell DCS
- All-in-One Configurable Calibration Station
- Features
-
- Complete dew-point calibration solution with optional compressor, dryer, dew-point generator, reference instrument and optional manifold
- Generated output responds quickly to a change of set point
- Stable humidity generation
- Simple operation through manual flow mixing or push-button switching of set points
- Remote control via RS232 comms (dependant on model)
Cost Effective Humidity Validator - Michell S904
- Stand-Alone Instrument for On-Site Humidity Validation
- Features
-
- Simple operation and maintenance
- Easy calibration of relative humidity sensors
- Excellent chamber stability and uniformity
- Manual control or optional straightforward automated set point programming
- Optional in-built data-logging for reference probe and probes under calibration
- Humidity and temperature-controlled chamber
- Generate 10 to 90% RH over +10 to +50°C temperature
- Transportable to allow on-site calibrations
Automatic Humidity Probe Calibrator - Michell HG10
- Reference Hygrometer Controlled Humidity Generation
- Features
-
- Automatic calibration system with reference hygrometer
- Wide range of humidity generation 1 to 95% RH, -50 to +50°Cdp
- High accuracy ±0.1°C fundamental reference
- User-configurable temperature and humidity profiling allows calibration cycles to be run without constant supervision
- Very fast changes between generated relative humidity points

-350x280.jpg)
-350x280.jpg)





-350x280.jpeg)