Cryostat Model 459

- -80°C to -180°C

- An apparatus immersed in liquid nitrogen will cool to approximately -195°C. Our design, using a controller and heater, permits the cryostat to be set at any temperature above liquid nitrogen temperature.

- Extreme Low Temperature Calibration

- High Stability

Brief specifications


More details

When we considered low temperature comparison calibration, we had to take into account Health and Safety considerations, both of the liquids used in compressors to generate low temperatures and also the liquids used in the calibration volume itself. The cost of chillers increases considerably for very low temperatures. We concluded that using chillers for very low temperatures was expensive, unsafe and unreliable. Our solution is a simple heated metal block design using a single, safe surrounding liquid, liquid nitrogen. An apparatus immersed in liquid nitrogen will cool to approximately -195°C. Our design, using a controller and heater, permits the cryostat to be set at any temperature above liquid nitrogen temperature. The Cryostat comprises an insulated machined copper equalizing block inside an 80mm diameter tube 480mm long, attached via a flange to a lid giving access for three thermometers, a vacuum port and a Lemo connector for the temperature sensor and heater. A cable runs to a controller which sets the temperature. An RS422 connector permits the calibration to be automated using one of our Software programs.


ВимірюванняГенерація (Імітація)


Документация

Cryostat Model 459

- -80°C to -180°C

- An apparatus immersed in liquid nitrogen will cool to approximately -195°C. Our design, using a controller and heater, permits the cryostat to be set at any temperature above liquid nitrogen temperature.

- Extreme Low Temperature Calibration

- High Stability

Featured Products

High End Humidity Transmitters - Rotronic HygroFlex HF5 and HF8
High End Humidity Transmitters - Rotronic HygroFlex HF5 and HF8
The HygroFlex5 series and HygroFlex 8 series is compatible with HC2A probes which offers a high variety in temperature ranges, accuracy and body types. This device generation also boasts a unique calibration and adjustment process as well a...
Код: HF5_HF8
ADT761A Automated Pressure Calibrator
ADT761A Automated Pressure Calibrator
At Additel, innovation and continuous improvement are part of our company's culture and the products we introduce. When we set out to deliver the Additel 761A series calibrators, we knew we needed to provide breakthrough improvements and ad...
Код: ADT761A
4857 Gemini 700
4857 Gemini 700
Need advice on which model? Dry Block Selection Guide The Gemini range of Dry Blocks have high capacity allowing a large number of probes to be calibrated together. They are also suitable to accept large diameter probes with the block volum...
5.0000/5 1text_less_review
Код: 4858
Oberon – for Slim Cells
Oberon – for Slim Cells
Model 426 is for Aluminium, Silver, Gold or Copper slim fixed point cells as well as for comparison calibration. Heat pipes provide the ideal conditions for the creation and maintenance of slim ITS-90 cells. The furnace core is a specially-...
4.2500/5 4text_more_review
Код:
IAPSO P35 Standard Seawater and Salinity Packs
The International Recognized Calibration Standard for Salinometers The International Association for Physical Sciences of the Ocean (IAPSO) Standard Seawater manufactured by Ocean Scientific International (OSIL) is available in North Americ...
Код: P35
AII GPR-3500 MOVR Portable Purity Oxygen Analyzer
The GPR-3500 MOVR Portable Oxygen Purity Analyzer is the only electrochemical oxygen sensor based analyzer capable of measuring 100% oxygen on a continuous 24/7 basis for the purpose of verifying the purity of medical grade oxygen transport...
Код: GPR-3500
7350 Series features High Stability, Precision Power AC/DC Current Calibration Standards
7350 Series features High Stability, Precision Power AC/DC Current Calibration Standards
GUILDLINE INSTRUMENTS provides two series of the best performing, most compact, wide-band AC current shunts that are commercially available PRODUCT FEATURES High Current Values to 100 A AC/DC Difference Essentially Zero at Power Frequencies...
Код: 7350
Annealing Furnace
Annealing Furnace
Designed to pre-warm and anneal Standard Platinum Resistance Thermometers Maintenance Free Use Automatic Temperature Cycling The Annealing Furnace, model 414, is designed to heat, anneal and cool Standard Platinum Resistance Thermometers (S...
Код:
Extension Cables for Rotronic Humidity Probes HC2-A and HC2
Extension Cables for Rotronic Humidity Probes HC2-A and HC2
The HC2-A extension cables extend the HC2-A probes away from transmitters, handheld instruments or data loggers and data loggers. The HC2-A extension cables can be used up to 5 meters...
Код: HC2
AC Shunt Accessories
Complete Selection of Measurement Accessories for the 7340 and 7350 Series of AC Shunts. AVAILABLE PRODUCTS AND FEATURES Forced Air Convection Unit provides excellent heat dissipation and a more stable output AC Buffer Amplifier for low cur...
Код: AC
IO620-IDT621 Dirt moisture trap
IO620-IDT621 Dirt moisture trap
Dirt moisture trap Prevents contamination of the PV621 and 622 pneumatic systems and cross contamination from one device under test to another. The IDT connects directly to the PV621 and 622 pressure port and replicates the quick fit connec...
Код: IO620-IDT621
6564 High to Ultra-High Resistance Scanners
6564 High to Ultra-High Resistance Scanners
Guildline’s 6564 High to Ultra-High Resistance Scanners are the first commercial scanners capable of operating with measurement capabilities to 10 PΩ’s and at voltages to 1000 Vdc. This capability greatly improves the measurement and calibr...
Код: 6564
Additel 100 Filter
The Additel 100-FLT-1K is a pneumatic filter and liquid trap covering from -15 to 1,000 psi (-1.0 to 70 bar). This filter is ideal for your pneumatic measurement or calibration applications and contains an easy to use drain valve for removi...
Код: ADT100
IO620-HOSE-P1 Pneumatic hose
IO620-HOSE-P1 Pneumatic hose
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Safe area use 1 m/3.28 ft pneumatic hose. Maximum pressure 400 bar/5800 psi...
Код: IO620-HOSE-P1
Nitrogen Boiling Point Apparatus
Nitrogen Boiling Point Apparatus
Isotech Nitrogen Boiling Point Apparatus is designed specifically to realise and maintain the liquid/vapour equilibrium (boiling point) of nitrogen or argon, for the calibration of thermometers on the International Temperature Scale of 1990...
4.0000/5 1text_less_review
Код:
3350A precision multiproduct calibrator
3350A precision multiproduct calibrator
The 33XXA Series multiproduct calibrators are modular versions of the class leading 3000A Series Calibrators. Designed to reduce cost, the 33XXA Series feature 0 - 20V DC output as standard with a wide range of options including 20V - 1000V...
3.7500/5 8text_lot_review
Код: 3350A
Precision Dew-Point Hygrometer - Michell S4000 TRS
The S4000 TRS measures very dry dew points down to -100 °C (-148 °F) with ±0.1 °C accuracy. It features excellent stability and reproducibility across its entire measurement range and is used in calibration and standards laboratories worldw...
Код: S4000 TRS
P5515  Hydraulic Pressure Test Pump
P5515  Hydraulic Pressure Test Pump
These instruments are used for checking pressure measuring instruments against master test gauges, indicators or transducers. These hydraulic pressure comparators provide a quick and easy solution for checking pressure measuring instruments...
Код: P5515
precis.io
precis.io
Application works as Control Software for products of Applied Precision. It can show measured values, control meter error measurement and generation of signals (in PTE device)...
Код: precis
Stirred Ice Bath Model 813
Stirred Ice Bath Model 813
The most used temperature for calibration is 0°C. The normal way of creating 0°C is via a mixture of ice and water in a Dewar Flask. However, this can give errors of up to 4°C because water is densest at 4°C and so as the ice melts the temp...
Код: 813
Спасибо!