Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

Nitrogen Boiling Point Apparatus

- -185°C to -196°C

- Isotech Nitrogen Boiling Point Apparatus is designed specifically to realise and maintain the liquid/vapour equilibrium (boiling point) of nitrogen or argon, for the calibration of thermometers on the International Temperature Scale of 1990.

- Boiling Point of Liquid Nitrogen

- Gas Manifold for Thermometers

- Self Contained - Bench Mounted

Brief specifications


More details

Isotech Nitrogen Boiling Point Apparatus is designed specifically to realise and maintain the liquid/vapour equilibrium (boiling point) of nitrogen or argon, for the calibration of thermometers on the International Temperature Scale of 1990. The Boiling Point Apparatus is self-contained and refrigerated by liquid nitrogen or liquid argon, which must be supplied by the user. Either liquid is suitable for the purpose. Liquid nitrogen is generally less costly and more readily available than liquid argon. The Apparatus does not require electrical power for its operation. The Boiling Point Apparatus will maintain the liquid-vapour equilibrium of nitrogen (-195.798°C) or of argon (-185.8468°C) indefinitely, provided boiled-off gas is replenished. ITS-90 specifies the triple point of argon (-189.3442°C) as the low end of the long-stem Standard Platinum Resistance Thermometer range. As a practical matter, realisation of this triple point is a costly (in equipment and time) and complicated process. Most laboratories will choose to calibrate this end of the platinum range by comparison of the thermometer under test with a thermometer of known calibration. National Laboratories themselves will invariably calibrate thermometers submitted to them by comparison, realising the actual argon triple point only infrequently for calibration of their own reference thermometers. The National Physical Laboratory of England makes this statement: “Most thermometers (submitted for calibration) will involve measurements (by) … comparison with NPL standards in a bath of liquid nitrogen (about -196°C)” Model 18205 Comparator is designed for precisely such comparison calibration. It comprises a stainless steel dewar, an inner equalising block having wells for 3 thermometers, top connections for filling and monitoring the level of liquid coolant, a pressure safety blow-off and a manifold which may be used to thermally tie the thermometers under test to the equalising block with helium gas (optional). Since the slopes (dR/dT) of Standard Platinum Resistance Thermometers are very similar at any temperature, calibration uncertainties not larger than 0.002K can be obtained at a small fraction of the cost of an absolute calibration.


ВимірюванняГенерація (Імітація)


Документация

Nitrogen Boiling Point Apparatus

- -185°C to -196°C

- Isotech Nitrogen Boiling Point Apparatus is designed specifically to realise and maintain the liquid/vapour equilibrium (boiling point) of nitrogen or argon, for the calibration of thermometers on the International Temperature Scale of 1990.

- Boiling Point of Liquid Nitrogen

- Gas Manifold for Thermometers

- Self Contained - Bench Mounted

Featured Products

Quick Cal Low
Quick Cal Low
Isotech’s Quick Cal range of testers are ideally suited to the less exacting applications where our larger, better specified baths are unnecessary. The Low Temperature Quick Cal covers the temperature range of -12°C to +140°C, making it ide...
Код: Quick Cal Low
1000B BENCHTOP ultra portable calibrator
1000B BENCHTOP ultra portable calibrator
The 1000 series has transformed the world of calibration - its innovative design utilises the latest in cutting edge digital and analogue electronics, combined with the latest manufacturing techniques to create the world's first ultra-porta...
Код: 1000B
Additel 878 Reference Dry Well Calibrator
Additel 878 Reference Dry Well Calibrator
Additel takes temperature calibration to the next level with the ADT878 reference dry block calibrators. If you're looking for the best dry-block calibrator on the market, you've found it! Additel's commitment to continuous improvement, qua...
Код: ADT878-425
AII GPR-1900 Oxygen Analyzer With Remote Sensor
A panel mounted oxygen analyser with a remote sensor allows flexibility of installation. The GPR-1900 gas analyzer is suitable for trace oxygen measurements as low as 0-10 ppm; the GPR-2900 measures O2 up to 100%. The remote sensor block al...
Код: GPR-1900
6622T Temperature Bridge Series
6622T Temperature Bridge Series
The 6622T Temperature Bridge Series expands upon the success of 6622A Series Resistance Bridges by utilizing new design features to offer leading uncertainties and stabilities for Temperature Bridges. The 6622T Operating Range is from 0.1 Ω...
Код: 6622T
TTI-10 High Accuracy Handheld Thermometer
TTI-10 High Accuracy Handheld Thermometer
TTI-10 brings laboratory level performance of up to 10mK (0.01°C) and resolution up to 0.001°C in a portable handheld instrument. Battery life is typically 20 hours from a 9V PP3 battery and a protective rubber boot offers protection in fie...
Код: I-10
6664C LOW THERMAL QUAD CHANNEL SCANNERS
6664C LOW THERMAL QUAD CHANNEL SCANNERS
THE 6664C LOW THERMAL QUAD CHANNEL SCANNERS ENABLES SOFTWARE CONTROLLED, FULLY AUTOMATED NORMAL AND HIGH OHM MEASUREMENTS WITH VOLTAGES UP TO 1000 V PRODUCT FEATURES Withstands up to 1000 Vdc to provide fully automated resistance measuremen...
Код: 6664C
9334A SERIES of Resistance Standards
9334A SERIES of Resistance Standards
GUILDLINE INSTRUMENTS 9334A SERIES of Resistance Standards are designed as very stable laboratory standards for high accuracy resistance calibration in air, without the need for a temperature controlled bath. PRODUCT FEATURES 12 Month Stabi...
Код: 9334A
Portable Test Equipment
Portable Test Equipment
The Portable Test Equipment consists of an integrated three-phase current and voltage source and a three-phase electronic reference standard of accuracy class 0.05% or 0.02%...
Код: PTE
AII GPR-1800 PPM Oxygen Analyzer
AII GPR-1800 PPM Oxygen Analyzer
The GPR-1800 series of intrinsically safe trace oxygen analyzers are designed for use in demanding process environments where the low detection limit down the AII’s industrial oxygen sensors can be well utilized. Typical for Analytical Indu...
Код: GPR-1800
PM620T Pressure modules TERPS
PM620T Pressure modules TERPS
PM620 now incorporates our unique range of TERPS resonant silicon pressure sensor technology, the PM620T and the PM620TS intrinsically safe version. Providing up to four times greater stability and higher accuracy than current pressure meas...
Код: PM620T
Terminal Adapter Model 956
Terminal Adapter Model 956
Our TTI range use high quality ‘Lemo’ connectors for the Pt100 inputs. This simple accessory provides 4mm Terminal Posts for the connection of bare wires, spade terminals or 4mm plugs – useful if a lot of probes are going to be used with th...
4.5000/5 2text_more_review
Код: 956
2080 17TH EDITION ELECTRICAL CHECK BOX electrical test equipment
Designed with low cost, portability and ease of use in mind, the 2080 provides on or off site verification of RCD testers, Loop testers, Continuity and Insulation testers and multifunction testers. The 2080 is simple to use and provides the...
Код: 2080
Additel Land DataStored Software
With Additel/Land software, you may download test results stored in the internal memory of Additel calibrators to a PC, and export the results to an excel file. It is a free software package...
Код: Land
Humidity Temperature Probes - Rotronic HC2-HK/C
HC2-HK25 / HC2-HK40 The handheld probe is especially suitable for mobile measurements of high temperatures. It measures humidity and temperature and calculates the dew/frost point. Applications Climatic and temperature chambers, dryers, ...
Код: HC2-HK/C
RPM4 Reference Pressure Monitor
RPM4 Reference Pressure Monitor
RPM4 is much more than a traditional pressure indicator State of the art performance from very low pressure to 280 MPa (40 000 psi)… advanced on-board features…compact and rugged…full local and remote communications…RPM4 is the perfect sol...
Код: RPM4
DG2, DG3, DG4 and VDS3 - Michell Dew-Point Generators
DG2, DG3, DG4 and VDS3 - Michell Dew-Point Generators
The Michell range of dew-point generators provides flexibility and control at a competitive price. Based on the volumetric mixing of dry and wet gases, the instruments can be controlled either manually or automatically to suit a wide range ...
Код: DG
9230A SERIES of precision DC current shunts / standards
9230A SERIES of precision DC current shunts / standards
Guildline Instruments 9230A SERIES of precision DC current shunts / standards are true 4-terminal devices intended for the precise measurement of DC current. They are constructed using elements made from a Guildline proprietary metal alloy ...
Код: 9230A
7330 Series of Oil Based Resistance Standards
7330 Series of Oil Based Resistance Standards
Guildline Instruments 7330 Series of Oil Based Resistance Standards are designed for high accuracy resistance calibration in oil (Fluid Baths) or in air. PRODUCT FEATURES Typical AC/DC Error ...
Код: 7330
Additel 282 Dual-Channel Reference Thermometer Readout
Additel 282 Dual-Channel Reference Thermometer Readout
Additel’s 282 Reference Thermometer Readout delivers the best possible accuracies and features in the palm of your hand With accuracy capabilities on par with laboratory grade thermometers, the ADT282 is capable of handling even your most c...
Код: ADT282
Спасибо!