Categories
-
Pressure
-
Temperature
-
Humidity
-
Electrical signals
- Calibrator of electrical signals
- Reference multimeters
- Voltage, resistance, frequency standards
- Precision bridges
- Teraohmmeter
- Reference electricity meters
- Installations for verification of electricity meters
- Power analyzers
- Voltage dividers
- Current shunts
- Precision current transformers
- Systems for measuring current
- Precision measuring systems
- Test Equipment
- Liquid and air baths for resistance measures
- Standards of conductivity (salinity)
- Software
- Accessories
- Multifunction calibrators
-
Flow measurement
-
Chemical composition
-
Complex solutions
-
Services
4010 advanced multiproduct calibrator
- DC voltage 0 - ± 1025 V (± 8 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 1 MHz (0.015%)
- AC current 20 μA - 30 A, 10 Hz - 30 kHz (0.04%)
- Resistance (passive) 0 Ohm - 1 GOhm (18 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (1 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Resistance (simulation) 0 ohm - 1 GOhm (100 ppm)
- DC voltage 0 - ± 1025V (± 4 ppm)
- DC current 0 - ± 30 A (± 7 ppm)
- DC current (electrometer input) 10 nA - ± 10 μA Ranges, 0.01 pA Resolution
- AC voltage 20 mV - 1025 V, 10 Hz -1 MHz (0.015%)
- AC current 0 A - 30A (0.03%)
- Resistance 0 Ohm - 1 GOhm (± 8 ppm)
- Resistance (electrometer) 10 mΩ - 1 TΩ, 10 V - 300 V (± 140 ppm)
- Frequency 10 Hz - 1 mHZ (± 5ppm)
- Temperature (PRT / RTD) 2.3 b 4 wires
- Temperature (thermocouple) support up to 8 thermocouples
- Rear Panel Terminals: Standard
4015 advanced multiproduct calibrator
- DC voltage 0 - ± 1025 V (± 15 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 500 KHz (0.015%)
- AC current 20 μA - 30 A, 10 Hz - 30 kHz (0.04%)
- Resistance (passive) 0 Ohm - 1 GOhm (40 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Resistance (simulation) 0 ohm - 1 GOhm (100 ppm)
- DC voltage 0 - ± 1025V (± 9 ppm)
- DC current 0 - ± 30 A (± 25 ppm)
- AC voltage 20 mV - 1025 V, 10 Hz -100 kHz (± 0.05%)
- AC current 0 A - 30A (± 0.08%)
- Resistance 0 Ohm - 1 GOhm (± 20 ppm)
- Frequency 10 Hz - 1 mHZ (± 5ppm)
4610M ADVANCED MULTIPRODUCT CALIBRATOR
AC & DC Voltage to 1000V
AC & DC Current to 30A
2/4 wire Decade and Variable Resistance to 1G
Decade and Variable Capacitance to 100mF
Frequency to 1MHz
Thermocouple Source & Measure
GPIB (IEEE-488) & USB interface standard
7″ full color touch screen
0 - 1000V DC
1mV - 1000V AC, 10Hz to 1MHz
Variable Resistance 0 Ohms to 1GOhms
Variable Capacitance 1nF to 100mF
10Hz to 1MHz Frequency Output
8158 Advanced Digitising Multimeter advanced multimeter
- DC voltage 0 - 1000 V (8 ppm)
- DC current 100 nA - 1.5 A
- AC voltage 0 - 1000 V
- AC current 100 mA - 1.5A
- Resistance 10 Ohm - 1 GOhm
- Front / Rear Inputs: Standard
3010A precision multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 8 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 1 MHz (0.015%)
- AC current 20 μA - 30 A, 10 Hz - 10 kHz (0.04%)
- Resistance (passive) 0 Ohm - 1 GOhm (18 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm / 1 ppm optional)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
8500 Low Thermal 10 Channel Scanner low thermal scanner
- Internal temperature 5 ° C to 35 ° C: Accuracy ± 0.1 ° C
- Humidity 10 to 90% RH: Accuracy 5%
- Main voltage 200V to 260V AC 50Hz
- Number of channels 10
- Changeover 4-pin changeover Kelvin: 2 Voltage: 2 Current
- Maximum voltage 200V
- Maximum current 1A
- Connection Front panel inputs 4mm terminal low thermal gold on
copper
- Thermal EMF is usually less than 150 nV
- Switching resistance Less than 0.2 ohm
- Latching relay type
- RS232 / USB interface (via adapter)
3041A precision multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 25 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 500 KHz (0.04%)
- AC current 20 μA - 30 A, 10 Hz - 10 kHz (0.06%)
- Resistance (passive) 0 Ohm - 1 GOhm (40 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm / 1 ppm optional)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
3050A precision multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 50 ppm)
- DC current 0 - ± 22 A (± 100 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 100 KHz
- AC current 20 μA - 22 A, 10 Hz - 10 kHz (0.07%)
- Resistance (passive) 0 Ohm - 100 MΩ (60 ppm)
- Capacitance (passive) 10 nF - 1 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
1000A PORTABLE ultra portable calibrator
- DC voltage 0 - ± 1000 V (± 80 ppm)
- DC current 0 - ± 10A (± 0.05%)
- AC voltage 0 - ± 1000 V (± 0.08%)
- AC current 0 - ± 10 A (± 0.1%)
- Resistance (passive) 0 Ohm - ± 100 MΩ (± 0.02%)
- Capacitance (passive) 10 nF - 1 μF (0.8%)
- Frequency 1 Hz - 100 KHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.22 ° C)
- Weight 9.2 kg
- Dimensions 257 * 432 * 180 mm (H, W, D)
1000B BENCHTOP ultra portable calibrator
- DC voltage 0 - ± 1000 V (± 80 ppm)
- DC current 0 - ± 10A (± 0.05%)
- AC voltage 0 - ± 1000 V (± 0.08%)
- AC current 0 - ± 10 A (± 0.1%)
- Resistance (passive) 0 Ohm - ± 100 MΩ (± 0.02%)
- Capacitance (passive) 10 nF - 1 μF (0.8%)
- Frequency 1 Hz - 100 KHz (20ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.22 ° C)
- Weight 9.5 kg
- Dimensions 180 * 447 * 297 mm (H, W, D)
9041A transportable multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 50 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 500 KHz (0.04%)
- AC current 20 μA - 30 A, 10 Hz - 10 kHz (0.06%)
- Resistance (passive) 0 Ohm - 1 GOhm (40 ppm)
- Capacitance (passive) 10 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm / 1 ppm optional)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Dry block temperature (optional) 25 ° C- 200 ° C (1 ° C)
- Blackbody temperature source (optional) 25 ° C- 200 ° C (1 ° C)
9050A transportable multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 50 ppm)
- DC current 0 - ± 22 A (± 100 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 100 KHz
- AC current 20 μA - 22 A, 10 Hz - 10 kHz (0.07%)
- Resistance (passive) 0 Ohm - 100 MΩ (60 ppm)
- Capacitance (passive) 10 nF - 1 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Dry block temperature (optional) 25 ° C- 200 ° C (1 ° C)
- Blackbody temperature source (optional) 25 ° C- 200 ° C (1 ° C)
3200B BENCHTOP electrical test equipment calibrator
- Continuity resistance standard accuracy 0.2Ω - 1kΩ 1% (0.25% Option)
- Continuity current 0 - 320mA 1.3%
- Insulation test voltage measurement 0Ω - 2GΩ 0.3% (0.1% Option)
- AC voltage output 100V - 400V 0.2%
- Loop resistance 3mA - 3A 1.2%
- PAT earth bond resistance 0.05Ω - 1kΩ 0.5%
- PAT earth bond current measurement 100mA - 30A 1.5%
- PAT insulation resistance 0Ω - 2GΩ 0.3% (0.1% Option)
- PAT leakage current 2mA - 7.7mA 1.5%
- PAT leakage test voltage 100V - 300V 1.5%
9200B PORTABLE electrical tesr equipment calibrator
- Continuity resistance standard accuracy 0.2Ω - 1kΩ 1% (0.25% Option)
- Continuity current 0 - 320mA 1.3%
- Insulation test voltage measurement 0Ω - 2GΩ 0.3% (0.1% Option)
- AC voltage output 100V - 400V 0.2%
- Loop resistance 3mA - 3A 1.2%
- PAT earth bond resistance 0.05Ω - 1kΩ 0.5%
- PAT earth bond current measurement 100mA - 30A 1.5%
- PAT insulation resistance 0Ω - 2GΩ 0.3% (0.1% Option)
- PAT leakage current 2mA - 7.7mA 1.5%
- PAT leakage test voltage 100V - 300V 1.5%
3310A precision multiproduct calibrator
- DC voltage 0 - ± 20 V (0 - ± 1000 V optional) (± 8 ppm)
- DC current (optional) 0 - ± 30 A (± 50 ppm)
- AC voltage (optional) 20 mV - 1000 V, 10 Hz -1 MHz (0.015%)
- AC current (optional) 20 μA - 30A, 10 Hz - 10 kHz (0.04%)
- Resistance (passive) (optional) 0 ohm - 1 GOhm (18 ppm)
- Capacitance (passive) (optional) 1 nF - 1 μF (0.25%)
3341A precision multiproduct calibrator
- DC voltage 0 - ± 20 V (0 - ± 1000 V optional) (± 25 ppm)
- DC current (optional) 0 - ± 30 A (± 50 ppm)
- AC voltage (optional) 20 mV - 1000 V, 10 Hz - 500 KHz (0.04%)
- AC current (optional) 20 μA - 30A, 10 Hz - 10 kHz (0.06%)
- Resistance (passive) (optional) 0 ohm - 1 GOhm (40 ppm)
- Capacitance (passive) (optional) 1 nF - 10 μF (0.25%)
3350A precision multiproduct calibrator
- DC voltage 0 - ± 20 V (0 - ± 1000 V optional) (± 50 ppm)
- DC current (optional) 0 - ± 22 A (± 100 ppm)
- AC voltage (optional) 20 mV - 1000 V, 10 Hz - 100 kHz
- AC current (optional) 20 μA - 22A, 10 Hz - 10 kHz (0.07%)
- Resistance (passive) (optional) 0 Ohm - 100 MΩ (60 ppm)
- Capacitance (passive) (optional) 10 nF - 1 μF (0.25%)
2080 17TH EDITION ELECTRICAL CHECK BOX electrical test equipment
Insulation Testers
RCD Testers
Loop Testers
Wiring Check
Included calibration checksheet for your instrument
2090 PROGRAMMABLE DECADE RESISTANCE BOX precision references and standards
0 - 10 kOhm
0.1% Accuracy (0.01% Accuracy option)
RS232 Interface
1 Watt power rating
Front panel display & controls
Virtual Front Panel software for PC
3000AC voltage reference precision references and standards
Calculable AC voltage reference source
Accuracy in the order of 10ppm
Traceable to any DC voltage multimeter with suitable accuracies
AC voltage with frequency to 1kHz
3000CS precision curent shunts precision references and standards
Precision current shunt array
Values 10mA through to 10A
1 year stability of up to 5ppm
4-Wire PT100 Output
Temperature coefficients of less than 0.6ppm/°C
3000HR precision resistance standard precision references and standards
Electrometer currents to 10nA
REsistance from 1 Mohm to 100 Gohm
Traceable to 1 GOhm standard
3000RS precision resistance standard precision references and standards
Decade resistances from 1 Ohm to 10MOhm
Temperature co-efficients as low as 0.1ppm/°C
Annual stabilities of better than 5ppm
Precision decade resistance reference
3000ZR precision zener reference precision references & standards
4 Banks of 10V and 1.018V outputs
Stability of better than 2ppm/year
Internal battery backup for transportation
9340-4T Series of precision RTD Simulators and DC Resistance Standards
- Resistance ranges from 1 µΩ to 10 kΩ
- For devices in the milliohm range
- For devices in microohm ranges
- The error is less than ± 0.01%
- Temperature coefficient less than 5 ppm/°C
AC/DC shunts precision references and standards
AC/DC differences from 1ppm
Shunt values for measurements between 1mA to 100A
From DC to 30kHz
Low inductance & capacitance flat frequency response
Simplifies precision calibration of calibrators and current sources
Can be used with a precision multimeter or an AC measurement standard
Additel 209/210 Series Loop Calibrator
- Accuracy to 0.01% of reading
- Measure, source, or simulate loop current
- Simultaneously mA and % span display
- HART 250Ω resistor in series with 24V loop
- ISO 17025-accredited calibration w/data included
Electricity Meter Test Equipment ELMA
The Electricity Meter Test Equipment ELMA due to modular concept enables to tailor specifications to specific laboratory demand Automated equipment for electricity meter testing The accuracy of the power and energy reference meter is available up to 0.01 %. The reference meter measures all main and influencing quantities inclusive harmonic analysis and distortion of the test signals. The available power and the maximum current of 240 A of extremely pure synthesized 4-quadrant test signal covers the needs of both precision and high capacity testing laboratories. The test signal can be created with user defined harmonic content and predefined signal shapes. The intelligent high resolution Local Evaluation Units use reflective optical sensors scanning the marks on meter's disk and passive sensors scanning the LED output of electronic meters. The sensors are insensitive to external light condition and possess auto-calibration capability eliminating manual adjustment. The optional optical communication channel enables simultaneous data exchange with electronic meters. The built-in remotely controlled dividers enable to evaluate high constant meters with light impulses up to 1 kHz. The handling system has capacity of several mobile meter trolleys with 20 tested meters each. The trolleys are prepared either for manual wiring of heavy current meters or can be equipped with quick-acting connectors for lower currents. Static version of handling system is also available. The optional precision electronically compensated transformers enable simultaneous test of electricity meters with interconnected current and voltage circuits. The wireless data acquisition Hand-Held Unit with integrated barcode laser scanner enables versatile local data acquisition from the tested meters. The supplied Control Software for Microsoft Windows enables multilingual operation with user definable vocabularies, user friendly configuration of testing procedures, database operations and Microsoft Office compatible user defined form of output documents to any system output device. Local net and database ensures automated data interchange, central evaluation and archivation in laboratories with multiple test equipments.
Electricity Meter Test Equipment ELMA 8x01
Automated compact system for precision laboratory testing The accuracy of the power and energy reference meter is available up to 0.01 %. The reference meter measures all main and influencing quantities inclusive harmonic analysis and distortion of the test signals. The available power and the maximum current of 240 A of extremely pure synthesized 4-quadrant test signal covers the needs of both precision and high capacity testing laboratories. The test signal can be created with user defined harmonic content. The intelligent high resolution Local Evaluation Units use reflective optical sensors scanning the marks on meter's disk and passive sensors scanning the LED output of electronic meters. The sensors are insensitive to external light condition and possess auto-calibration capability eliminating manual adjustment. The optional optical communication channel enables simultaneous data exchange with electronic meters. The built-in remotely controlled dividers enable to evaluate high constant meters with light impulses up to 1 kHz. Suspension frame for 1, 2 or 3 positions is equipped with quick-acting connector system. The optional precision electronically compensated transformers enable simultaneous test of electricity meters with interconnected current and voltage circuits. The supplied Control Software for Microsoft Windows enables multilingual operation with user definable vocabularies, user friendly configuration of testing procedures, database operations and Microsoft Office compatible user defined form of output documents to any system output device. Optional local net and database ensures automated data interchange, central evaluation and archivation in laboratories with multiple test equipments.
Flexible Current Probe SymmProFlex FCP 2x21
Precision flexible AC current probe for current, power, energy and electricity quality applications Accuracy up to 0.2 % in amplitude and 0.05 ° in phase No additional error for wire position Symmetric flexible shielding pp for excellent suppression of strange electric fields Symmetric sensor coil pp for excellent suppression of strange magnetic fields Low noise, dual gain, high CMRR amplifier with precision integrator pp Low output impedance Super flexible sensor cable Ø 6 mm Application tailored pp sensor cable sensitivity and frequency range (optional)
Flexible Current Probe SymmProFlex FCP 3x21
- Precision flexible AC current probe for current, power, energy and electricity quality applications
- Accuracy up to 0.2 % in amplitude and 0.1 ° in phase
- No additional error for wire position
- Symmetric flexible shielding pp for excellent suppression of strange electric fields
- Symmetric sensor coil pp for excellent suppression of strange magnetic fields Low noise, dual gain, high CMRR amplifier with precision integrator pp Low output impedance
- Super flexible sensor cable Ø 6 mm
- Low cost models with software calibration in serial EEPROM available in single or three phase version
- Extremely long sensor cable pp for large structures like buildings, towers, masts etc. (optional)
- Application tailored pp sensor cable sensitivity and frequency range (optional)
- High frequency matched pp sensor coil for broad frequency band and surge current measurements (optional)
- Calibration kit available (optional)
Flexible Current Transformer FCT 2161
- Precision flexible AC current transformer for current, power, energy and electricity quality applications
- Accuracy up to class 0.2 %
- Accuracy specification includes wire position influence
- Symmetric flexible shielding pp for excellent suppression of strange electric fields
- Symmetric sensor coil pp for excellent suppression of strange magnetic fields
- Composite sensor core for low TC and long term stability
- Super flexible sensor cable Ø 6 mm
- High load capability

-350x280.jpg)
-350x280.jpg)





-350x280.jpeg)