Categories
-
Pressure
-
Temperature
-
Humidity
-
Electrical signals
- Calibrator of electrical signals
- Reference multimeters
- Voltage, resistance, frequency standards
- Precision bridges
- Teraohmmeter
- Reference electricity meters
- Installations for verification of electricity meters
- Power analyzers
- Voltage dividers
- Current shunts
- Precision current transformers
- Systems for measuring current
- Precision measuring systems
- Test Equipment
- Liquid and air baths for resistance measures
- Standards of conductivity (salinity)
- Software
- Accessories
- Multifunction calibrators
-
Flow measurement
-
Chemical composition
-
Complex solutions
-
Services
4010 advanced multiproduct calibrator
- DC voltage 0 - ± 1025 V (± 8 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 1 MHz (0.015%)
- AC current 20 μA - 30 A, 10 Hz - 30 kHz (0.04%)
- Resistance (passive) 0 Ohm - 1 GOhm (18 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (1 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Resistance (simulation) 0 ohm - 1 GOhm (100 ppm)
- DC voltage 0 - ± 1025V (± 4 ppm)
- DC current 0 - ± 30 A (± 7 ppm)
- DC current (electrometer input) 10 nA - ± 10 μA Ranges, 0.01 pA Resolution
- AC voltage 20 mV - 1025 V, 10 Hz -1 MHz (0.015%)
- AC current 0 A - 30A (0.03%)
- Resistance 0 Ohm - 1 GOhm (± 8 ppm)
- Resistance (electrometer) 10 mΩ - 1 TΩ, 10 V - 300 V (± 140 ppm)
- Frequency 10 Hz - 1 mHZ (± 5ppm)
- Temperature (PRT / RTD) 2.3 b 4 wires
- Temperature (thermocouple) support up to 8 thermocouples
- Rear Panel Terminals: Standard
4015 advanced multiproduct calibrator
- DC voltage 0 - ± 1025 V (± 15 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 500 KHz (0.015%)
- AC current 20 μA - 30 A, 10 Hz - 30 kHz (0.04%)
- Resistance (passive) 0 Ohm - 1 GOhm (40 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Resistance (simulation) 0 ohm - 1 GOhm (100 ppm)
- DC voltage 0 - ± 1025V (± 9 ppm)
- DC current 0 - ± 30 A (± 25 ppm)
- AC voltage 20 mV - 1025 V, 10 Hz -100 kHz (± 0.05%)
- AC current 0 A - 30A (± 0.08%)
- Resistance 0 Ohm - 1 GOhm (± 20 ppm)
- Frequency 10 Hz - 1 mHZ (± 5ppm)
4610M ADVANCED MULTIPRODUCT CALIBRATOR
AC & DC Voltage to 1000V
AC & DC Current to 30A
2/4 wire Decade and Variable Resistance to 1G
Decade and Variable Capacitance to 100mF
Frequency to 1MHz
Thermocouple Source & Measure
GPIB (IEEE-488) & USB interface standard
7″ full color touch screen
0 - 1000V DC
1mV - 1000V AC, 10Hz to 1MHz
Variable Resistance 0 Ohms to 1GOhms
Variable Capacitance 1nF to 100mF
10Hz to 1MHz Frequency Output
8158 Advanced Digitising Multimeter advanced multimeter
- DC voltage 0 - 1000 V (8 ppm)
- DC current 100 nA - 1.5 A
- AC voltage 0 - 1000 V
- AC current 100 mA - 1.5A
- Resistance 10 Ohm - 1 GOhm
- Front / Rear Inputs: Standard
3010A precision multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 8 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 1 MHz (0.015%)
- AC current 20 μA - 30 A, 10 Hz - 10 kHz (0.04%)
- Resistance (passive) 0 Ohm - 1 GOhm (18 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm / 1 ppm optional)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
8500 Low Thermal 10 Channel Scanner low thermal scanner
- Internal temperature 5 ° C to 35 ° C: Accuracy ± 0.1 ° C
- Humidity 10 to 90% RH: Accuracy 5%
- Main voltage 200V to 260V AC 50Hz
- Number of channels 10
- Changeover 4-pin changeover Kelvin: 2 Voltage: 2 Current
- Maximum voltage 200V
- Maximum current 1A
- Connection Front panel inputs 4mm terminal low thermal gold on
copper
- Thermal EMF is usually less than 150 nV
- Switching resistance Less than 0.2 ohm
- Latching relay type
- RS232 / USB interface (via adapter)
3041A precision multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 25 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 500 KHz (0.04%)
- AC current 20 μA - 30 A, 10 Hz - 10 kHz (0.06%)
- Resistance (passive) 0 Ohm - 1 GOhm (40 ppm)
- Capacitance (passive) 1 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm / 1 ppm optional)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
3050A precision multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 50 ppm)
- DC current 0 - ± 22 A (± 100 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 100 KHz
- AC current 20 μA - 22 A, 10 Hz - 10 kHz (0.07%)
- Resistance (passive) 0 Ohm - 100 MΩ (60 ppm)
- Capacitance (passive) 10 nF - 1 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
1000A PORTABLE ultra portable calibrator
- DC voltage 0 - ± 1000 V (± 80 ppm)
- DC current 0 - ± 10A (± 0.05%)
- AC voltage 0 - ± 1000 V (± 0.08%)
- AC current 0 - ± 10 A (± 0.1%)
- Resistance (passive) 0 Ohm - ± 100 MΩ (± 0.02%)
- Capacitance (passive) 10 nF - 1 μF (0.8%)
- Frequency 1 Hz - 100 KHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.22 ° C)
- Weight 9.2 kg
- Dimensions 257 * 432 * 180 mm (H, W, D)
1000B BENCHTOP ultra portable calibrator
- DC voltage 0 - ± 1000 V (± 80 ppm)
- DC current 0 - ± 10A (± 0.05%)
- AC voltage 0 - ± 1000 V (± 0.08%)
- AC current 0 - ± 10 A (± 0.1%)
- Resistance (passive) 0 Ohm - ± 100 MΩ (± 0.02%)
- Capacitance (passive) 10 nF - 1 μF (0.8%)
- Frequency 1 Hz - 100 KHz (20ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.22 ° C)
- Weight 9.5 kg
- Dimensions 180 * 447 * 297 mm (H, W, D)
9041A transportable multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 50 ppm)
- DC current 0 - ± 30 A (± 50 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 500 KHz (0.04%)
- AC current 20 μA - 30 A, 10 Hz - 10 kHz (0.06%)
- Resistance (passive) 0 Ohm - 1 GOhm (40 ppm)
- Capacitance (passive) 10 nF - 10 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm / 1 ppm optional)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Dry block temperature (optional) 25 ° C- 200 ° C (1 ° C)
- Blackbody temperature source (optional) 25 ° C- 200 ° C (1 ° C)
9050A transportable multiproduct calibrator
- DC voltage 0 - ± 1000 V (± 50 ppm)
- DC current 0 - ± 22 A (± 100 ppm)
- AC voltage 20 mV - 1000 V, 10 Hz - 100 KHz
- AC current 20 μA - 22 A, 10 Hz - 10 kHz (0.07%)
- Resistance (passive) 0 Ohm - 100 MΩ (60 ppm)
- Capacitance (passive) 10 nF - 1 μF (0.25%)
- Frequency 1 Hz - 10 MHz (20 ppm)
- Temperature (thermocouples) J / K / T / R / S / B / U / N / E / L / U / C / 10 μV ° C (± 0.09 ° C)
- Dry block temperature (optional) 25 ° C- 200 ° C (1 ° C)
- Blackbody temperature source (optional) 25 ° C- 200 ° C (1 ° C)
3200B BENCHTOP electrical test equipment calibrator
- Continuity resistance standard accuracy 0.2Ω - 1kΩ 1% (0.25% Option)
- Continuity current 0 - 320mA 1.3%
- Insulation test voltage measurement 0Ω - 2GΩ 0.3% (0.1% Option)
- AC voltage output 100V - 400V 0.2%
- Loop resistance 3mA - 3A 1.2%
- PAT earth bond resistance 0.05Ω - 1kΩ 0.5%
- PAT earth bond current measurement 100mA - 30A 1.5%
- PAT insulation resistance 0Ω - 2GΩ 0.3% (0.1% Option)
- PAT leakage current 2mA - 7.7mA 1.5%
- PAT leakage test voltage 100V - 300V 1.5%
9200B PORTABLE electrical tesr equipment calibrator
- Continuity resistance standard accuracy 0.2Ω - 1kΩ 1% (0.25% Option)
- Continuity current 0 - 320mA 1.3%
- Insulation test voltage measurement 0Ω - 2GΩ 0.3% (0.1% Option)
- AC voltage output 100V - 400V 0.2%
- Loop resistance 3mA - 3A 1.2%
- PAT earth bond resistance 0.05Ω - 1kΩ 0.5%
- PAT earth bond current measurement 100mA - 30A 1.5%
- PAT insulation resistance 0Ω - 2GΩ 0.3% (0.1% Option)
- PAT leakage current 2mA - 7.7mA 1.5%
- PAT leakage test voltage 100V - 300V 1.5%
3310A precision multiproduct calibrator
- DC voltage 0 - ± 20 V (0 - ± 1000 V optional) (± 8 ppm)
- DC current (optional) 0 - ± 30 A (± 50 ppm)
- AC voltage (optional) 20 mV - 1000 V, 10 Hz -1 MHz (0.015%)
- AC current (optional) 20 μA - 30A, 10 Hz - 10 kHz (0.04%)
- Resistance (passive) (optional) 0 ohm - 1 GOhm (18 ppm)
- Capacitance (passive) (optional) 1 nF - 1 μF (0.25%)
3341A precision multiproduct calibrator
- DC voltage 0 - ± 20 V (0 - ± 1000 V optional) (± 25 ppm)
- DC current (optional) 0 - ± 30 A (± 50 ppm)
- AC voltage (optional) 20 mV - 1000 V, 10 Hz - 500 KHz (0.04%)
- AC current (optional) 20 μA - 30A, 10 Hz - 10 kHz (0.06%)
- Resistance (passive) (optional) 0 ohm - 1 GOhm (40 ppm)
- Capacitance (passive) (optional) 1 nF - 10 μF (0.25%)
3350A precision multiproduct calibrator
- DC voltage 0 - ± 20 V (0 - ± 1000 V optional) (± 50 ppm)
- DC current (optional) 0 - ± 22 A (± 100 ppm)
- AC voltage (optional) 20 mV - 1000 V, 10 Hz - 100 kHz
- AC current (optional) 20 μA - 22A, 10 Hz - 10 kHz (0.07%)
- Resistance (passive) (optional) 0 Ohm - 100 MΩ (60 ppm)
- Capacitance (passive) (optional) 10 nF - 1 μF (0.25%)
2080 17TH EDITION ELECTRICAL CHECK BOX electrical test equipment
Insulation Testers
RCD Testers
Loop Testers
Wiring Check
Included calibration checksheet for your instrument
2090 PROGRAMMABLE DECADE RESISTANCE BOX precision references and standards
0 - 10 kOhm
0.1% Accuracy (0.01% Accuracy option)
RS232 Interface
1 Watt power rating
Front panel display & controls
Virtual Front Panel software for PC
3000AC voltage reference precision references and standards
Calculable AC voltage reference source
Accuracy in the order of 10ppm
Traceable to any DC voltage multimeter with suitable accuracies
AC voltage with frequency to 1kHz
3000CS precision curent shunts precision references and standards
Precision current shunt array
Values 10mA through to 10A
1 year stability of up to 5ppm
4-Wire PT100 Output
Temperature coefficients of less than 0.6ppm/°C
3000HR precision resistance standard precision references and standards
Electrometer currents to 10nA
REsistance from 1 Mohm to 100 Gohm
Traceable to 1 GOhm standard
3000RS precision resistance standard precision references and standards
Decade resistances from 1 Ohm to 10MOhm
Temperature co-efficients as low as 0.1ppm/°C
Annual stabilities of better than 5ppm
Precision decade resistance reference
3000ZR precision zener reference precision references & standards
4 Banks of 10V and 1.018V outputs
Stability of better than 2ppm/year
Internal battery backup for transportation
9340-4T Series of precision RTD Simulators and DC Resistance Standards
- Resistance ranges from 1 µΩ to 10 kΩ
- For devices in the milliohm range
- For devices in microohm ranges
- The error is less than ± 0.01%
- Temperature coefficient less than 5 ppm/°C
AC/DC shunts precision references and standards
AC/DC differences from 1ppm
Shunt values for measurements between 1mA to 100A
From DC to 30kHz
Low inductance & capacitance flat frequency response
Simplifies precision calibration of calibrators and current sources
Can be used with a precision multimeter or an AC measurement standard
Additel 209/210 Series Loop Calibrator
- Accuracy to 0.01% of reading
- Measure, source, or simulate loop current
- Simultaneously mA and % span display
- HART 250Ω resistor in series with 24V loop
- ISO 17025-accredited calibration w/data included
Electricity Meter Test Equipment ELMA
The Electricity Meter Test Equipment ELMA due to modular concept enables to tailor specifications to specific laboratory demand Automated equipment for electricity meter testing The accuracy of the power and energy reference meter is available up to 0.01 %. The reference meter measures all main and influencing quantities inclusive harmonic analysis and distortion of the test signals. The available power and the maximum current of 240 A of extremely pure synthesized 4-quadrant test signal covers the needs of both precision and high capacity testing laboratories. The test signal can be created with user defined harmonic content and predefined signal shapes. The intelligent high resolution Local Evaluation Units use reflective optical sensors scanning the marks on meter's disk and passive sensors scanning the LED output of electronic meters. The sensors are insensitive to external light condition and possess auto-calibration capability eliminating manual adjustment. The optional optical communication channel enables simultaneous data exchange with electronic meters. The built-in remotely controlled dividers enable to evaluate high constant meters with light impulses up to 1 kHz. The handling system has capacity of several mobile meter trolleys with 20 tested meters each. The trolleys are prepared either for manual wiring of heavy current meters or can be equipped with quick-acting connectors for lower currents. Static version of handling system is also available. The optional precision electronically compensated transformers enable simultaneous test of electricity meters with interconnected current and voltage circuits. The wireless data acquisition Hand-Held Unit with integrated barcode laser scanner enables versatile local data acquisition from the tested meters. The supplied Control Software for Microsoft Windows enables multilingual operation with user definable vocabularies, user friendly configuration of testing procedures, database operations and Microsoft Office compatible user defined form of output documents to any system output device. Local net and database ensures automated data interchange, central evaluation and archivation in laboratories with multiple test equipments.
Electricity Meter Test Equipment ELMA 8x01
Automated compact system for precision laboratory testing The accuracy of the power and energy reference meter is available up to 0.01 %. The reference meter measures all main and influencing quantities inclusive harmonic analysis and distortion of the test signals. The available power and the maximum current of 240 A of extremely pure synthesized 4-quadrant test signal covers the needs of both precision and high capacity testing laboratories. The test signal can be created with user defined harmonic content. The intelligent high resolution Local Evaluation Units use reflective optical sensors scanning the marks on meter's disk and passive sensors scanning the LED output of electronic meters. The sensors are insensitive to external light condition and possess auto-calibration capability eliminating manual adjustment. The optional optical communication channel enables simultaneous data exchange with electronic meters. The built-in remotely controlled dividers enable to evaluate high constant meters with light impulses up to 1 kHz. Suspension frame for 1, 2 or 3 positions is equipped with quick-acting connector system. The optional precision electronically compensated transformers enable simultaneous test of electricity meters with interconnected current and voltage circuits. The supplied Control Software for Microsoft Windows enables multilingual operation with user definable vocabularies, user friendly configuration of testing procedures, database operations and Microsoft Office compatible user defined form of output documents to any system output device. Optional local net and database ensures automated data interchange, central evaluation and archivation in laboratories with multiple test equipments.
Flexible Current Probe SymmProFlex FCP 2x21
Precision flexible AC current probe for current, power, energy and electricity quality applications Accuracy up to 0.2 % in amplitude and 0.05 ° in phase No additional error for wire position Symmetric flexible shielding pp for excellent suppression of strange electric fields Symmetric sensor coil pp for excellent suppression of strange magnetic fields Low noise, dual gain, high CMRR amplifier with precision integrator pp Low output impedance Super flexible sensor cable Ø 6 mm Application tailored pp sensor cable sensitivity and frequency range (optional)
Flexible Current Probe SymmProFlex FCP 3x21
- Precision flexible AC current probe for current, power, energy and electricity quality applications
- Accuracy up to 0.2 % in amplitude and 0.1 ° in phase
- No additional error for wire position
- Symmetric flexible shielding pp for excellent suppression of strange electric fields
- Symmetric sensor coil pp for excellent suppression of strange magnetic fields Low noise, dual gain, high CMRR amplifier with precision integrator pp Low output impedance
- Super flexible sensor cable Ø 6 mm
- Low cost models with software calibration in serial EEPROM available in single or three phase version
- Extremely long sensor cable pp for large structures like buildings, towers, masts etc. (optional)
- Application tailored pp sensor cable sensitivity and frequency range (optional)
- High frequency matched pp sensor coil for broad frequency band and surge current measurements (optional)
- Calibration kit available (optional)
Flexible Current Transformer FCT 2161
- Precision flexible AC current transformer for current, power, energy and electricity quality applications
- Accuracy up to class 0.2 %
- Accuracy specification includes wire position influence
- Symmetric flexible shielding pp for excellent suppression of strange electric fields
- Symmetric sensor coil pp for excellent suppression of strange magnetic fields
- Composite sensor core for low TC and long term stability
- Super flexible sensor cable Ø 6 mm
- High load capability
- Microcomputer unit for evaluation of error of the tested electricity meter
- Remotely configurable either for reflexive mark or SO output of electromechanical or LED of electronic meters.
- The reflex scanner work with coded signal to suppress false light signals.
- The auto-calibration capability significantly increases the work comfort and productivity of the test system.
- The built-in remotely controlled dividers enable to evaluate high constant meters with light impulses up to 2.5 kHz.
- Variable pre-divider enables direct measurement of standard meters with impulse output up to 500 kHz.
- The built-in manual switch enables effective local control of individual unit and data input for tests with operator interactions.
Handling system for electricity meter testing and calibration The modular design of the stand system permits building of various capacity test equipments in accordance with laboratory requirements. The stand system may consist of up to four stands. Each of the stands has a capacity for evaluation of up to 20 electricity meters, either single-phase or poly-phase, 10 meters on one side. Construction of the system enables customized placement to fit any laboratory area for easy handling and optimal meters calibration and testing. The movable trolleys permit easy handling and optimal processing of technological operations. The trolleys can be equipped with single-phase or poly-phase quick connection mechanism. The manual wiring system for single-phase, two-phase and three-phase meters can handle up to 120 A. The trolleys can be equipped with optional Precision Electronically Compensated Transformers (CMR-I or CMR-U), enabling simultaneous testing of meters with interconnected voltage and current circuits. The mobile system is dedicated to fully automated electronic equipment ELMA or to a partial modernization of existing electromechanical systems. Static versions of various capacity meter handling systems are also available.
Precision meter for electrical power and energy measurement 7” Colour Multi-Touch Screen Highest accuracy 0.01 % (optionally up to 0.005 %) Wide measuring range 0.1 mA to 120 A and 0.1 V to 600 V Extreme bandwidth 10 kHz and sampling rate 24-bit 125 000 samples/second Harmonics and interharmonics up to 200th harmonic (digital processing up to 1024th harmonic) Current and voltage inputs designed for safety category CAT IV 300 V / CAT III 600 V Digital inputs for external smart voltage and current sensors (inclusive high current AC and DC sensors) Four independent impulse inputs Four independent fully programmable impulse outputs assignable to selected quantities Programmable constant of the impulse outputs up to 4 MHz Ethernet networking for worldwide remote control and data exchange
Multifunction portable signal source with integrated working standard of power and energy Laboratory and on-site meter measurements Easy evaluation of meters under precise load conditions, using the built-in compact current and voltage source Testing of meters with closed I-P links Automatic operation with predefined load points without the need for an external computer Each source channel can be programmed with user defined harmonic content or standardized signal test shape Each source channel can be modulated with programmable Ripple control telegram Independent generation of single or three-phase loading conditions for testing, calibration and verification of meters Active, reactive and apparent energy measurement for 3 phase, 3 or 4-wire, systems with integrated error calculator and pulse output
- Precision high power voltage and current source
- Modular design with simple customization
- Signal generation based on digital synthesis of the signal waveform
- High efficiency of power output stages with extremely high fidelity and noise-free output
- Switch mode output stage with efficiency better than 85%
- Android application for products of Applied Precision Ltd
- Application for any Android device with Android 4.2 or higher
- Bluetooth communication with AP products
- Control Software for products of Applied Precision Ltd.
- Currently supported AP products: Working Standard 2x20 and Portable Test Equipment 2x00
- Available free of charge in Google Play store
Precision Electronically Compensated Current Transformer CMR-I ™
Isolation current transformer for testing meters with interconnected current and voltage circuits The Precision Electronically Compensated Current Transformer CMR-I is a small-sized electronically compensated current transformer unit for isolated precision current transmission. The through-hole concept and single wire capability enable any user defined current ratio. The unit is dedicated for testing of electricity meters with closed current-potential circuits and for universal step-up/down current transformation applications with excellent accuracy and dynamics. Highlights Standalone through-hole precision electronically compensated transformer with single wire capability Excellent accuracy and dynamics Remote control via serial communication Monitoring of individual contact resistance and power loss Protection against open circuit and overload Programmable load by-pass Automatic unused position by-pass Easy prepaid and smart meters testing Easy implementation to existing systems Simple user test of functionality and accuracy Accuracy maintained for any up or down current transformation
Precision Electronically Compensated Voltage Transformer CMR-U
Isolation voltage transformer for testing meters with interconnected current and voltage circuits The Precision Electronically Compensated Voltage Transformer CMR-U is a universal small-sized electronically controlled precision voltage transformer for galvanically isolated voltage transmission. The unity voltage ratio is dedicated for testing single-phase electricity meters with closed current and potential circuits but its versatility enables utilization in extensive applications. The built-in active shielding between input and output eliminates capacitive current from input side to the isolated output device. Highlights DIN rail mounting possibility Accuracy class 0.05, 0.02 Compensation of residual capacitive current from the input to output Operation without external power supply Unity transfer ratio of the CMR-U unit enables simple user test of functionality and accuracy Built-in short circuit, overload and misconnection protection Easy user-friendly mounting, negligible power consumption and built-in protection permit simple extension of any existing meter test equipment to closed I-P link testing capability
PROCAL -TRACK laboratory management software
Advanced asset tracking software
Automate workload management
Generation of re-calibration notification emails and letters
Instrument history tracking
Quality system integration for ISO 17025
Simplify your calibration through easy to use, fast and reliable software from Transmille. ProCal can automate your test equipment and increase productivity while reducing errors.
Easy to use calibration software
Enables full automation of calibration
New SQL database for improved speed
Works on windows 7/8/8.1 and 10
Built in drivers for common instruments
Automatic uncertainty calculations to M3003 / GUM
PROEDIT procedure builder and editor
Simple wizard-based interface
Fast and easy procedure creation
Matches the format of most test equipment datasheets
PROSALES sales management software
Automate costing processes
Maintain customer relationship management database
Integrates with existing accounts packages
Fully integrates with ProCal and ProCal-Track
PROSITE on-site calibration database
Enable export of your laboratory database to an on-site laptop
Reduce data re-entry and replication through an automated process
Enables simple use of ProCal calibration software to automate on-site calibration
PROWEB web based certificate database
Enables upload of certificates in PDF format
Password protected access to certificates
Provides example code for integration into existing websites
Precision meter for electrical power and energy measurement Precision 24-bit A/D conversion and digital signal processing Single-phase and three-phase versions in classes 0.1, 0.05, 0.02, 0.01 Independent input channels (three fully independent differential voltage input circuits in three-phase version) Current measurement up to 120 / 160 / 200 A or with Current Extender up to 240 A Continuous voltage and current ranges with auto-range functionality Programmable meter constant Four independent fully programmable impulse outputs assignable to various quantities or constant frequency Direct meter testing possibility (with supplied accessories) Portable with special transport case Rack mountable with 2U form factor
- Complete software package for electricity meter testing and calibration
- User friendly programs for Microsoft Windows Network support in distributed systems: client / server communication with central database via any type of computer network
- Simple input of meter parameters, user defined tests, sequences, addresses and user friendly operations with respective databases
- User defined test limits with support of IEC standards and local regulations
- Graphic representation of measurement results, deviations and curves
- Free defined output documents for Microsoft Office
- Support of mobile terminals for manual or barcode data acquisition
- Possibility of any harmonic content definition in measuring power signals
- Support of data exchange with electronic meters
- Simultaneous test of meters with different constants
Phone and Screen Sharing support
New and improved software functionality
Discounts on crystal report customisation
Multifunction hand-held Working Standard of power and energy for on site meter testing Lightweight compact size Single- and three-phase versions, accuracy classes 0.2, 0.1, 0.05, 0.02 Color graphic display and alphanumerical keypad USB, RS-232 and optical interface for local data exchange with multi-functional meters according to IEC 62056-21 Configuration and data stored in high capacity memory (min. 2 GB) Vector diagram and signal shape display (oscilloscope mode) Harmonics analysis in tabular and graphical format LED and TTL impulse outputs with programmable energy proportional meter constant or programmable frequency Enhanced internal database system for tested meters and measured results with search capabilities Enhanced self-adjusting optical scanning head Synchronous differential energy consumption measurement Two universal input channels for any combination of Voltage and Current probes for Power or CT / VT ratio, phase and burden measurement Optional wireless communication interface and wireless scanning head network for simultaneous testing of multiple delivery nodes Enhanced fast synchronization of measured data and configuration with PC PC software for MS Windows Transport case with high protection degree Optional portable printer for printing of results and actual display content Optional universal isolated input/output (relay, logic signal) Configurable user interface (regional and functional modifications)
Working Standard WS 2330 Series
- Precision flexible AC current sensor for current, power, energy and electricity quality applications
- Accuracy up to 0.2 % includes wire position influence
- Composite core for low TC Broad frequency range
- Accuracy specification includes wire position influence
- Symmetric flexible shielding pp for excellent suppression of strange electric fields
- Symmetric sensor coil pp for excellent suppression of strange magnetic fields
- Super flexible sensor cable Ø 6 mm Safety wear indicator outer layer

-350x280.jpg)
-350x280.jpg)





-350x280.jpeg)