Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

Laminar Flow Elements

- Flow range: 0.012 to 4000 m³/h

- Measurement accuracy: up to 0.5 % MV

- Widest measurement range: up to 1:100

- Low-pressure loss: up to 20 mbar

Brief specifications

Flow range: 0.012 to 4000 m³/h

Measurement accuracy: up to 0.5 % MV

Widest measurement range: up to 1:100

Low-pressure loss: up to 20 mbar

More details

Laminar Flow Elements

Flow measurement elements with highest accuracy

EP Ehrler Prüftechnik manufactures LFEs in the flow range from 0.012 to 4000 m³/h. In addition to the standard range, EP offers customer-specific LFEs that are perfectly designed for your application. Suitable inlet and outlet sections and the associated mounting accessories are available for all sizes for installation in customer applications.

The achievable measurement accuracy depends significantly on the sensor technology used, in particular on the differential pressure sensor. When using high-quality sensors, measurement accuracies* of up to 0.5 % MV can be achieved with LFEs in the measuring range of 1:10. In order to cover a very wide measurement range without restrictions in measurement accuracy, LFEs with overlapping flow ranges can be combined in one measurement setup. Alternatively, LFEs with correspondingly lower measurement accuracy can also be calibrated for an extended measurement range up to a maximum of 1:100.

*Higher measurement accuracies on request

Application examples
Calibration of flow meters, e.g. gas meters, LFE, Venturi nozzles, MFM, MFC
Determination of characteristic curves for valves, fans, filters, etc.
Flow measurement, e.g. for intake air measurement on engine test benches or in sample test benches for tank venting valves
Production monitoring of components


ВимірюванняГенерація (Імітація)


Laminar Flow Elements

- Flow range: 0.012 to 4000 m³/h

- Measurement accuracy: up to 0.5 % MV

- Widest measurement range: up to 1:100

- Low-pressure loss: up to 20 mbar

Featured Products

Fast-Cal Low
Fast-Cal Low
Fast-Cal – the product range you designed During early 2004 20 experienced engineers from many parts of the world were asked to produce their ideal specification for industrial calibration. Their top ten requirements, in order of priority, ...
Код: Low
ADT912-X-KIT Test kit for connection
A set for connecting measuring equipment with each other using silicone tubes (fittings, silicone tubes and adapters). X = connection type, eg N - 1/4 NPT male, N2 - 1/2 NPT male, B - 1/4 BSP male, B2 - 1/2 BSP male, M - M20X1.5 male...
Код: ADT912-X-KIT
8104 precision multimeter
8104 precision multimeter
The 8100 Series from Transmille is the most advanced multimeter available on the market. Featuring a full colour screen, the 8100 Series offers a wide range of functionality and covers a wide range of input parameters whilst achieving break...
Код: 8104
P5531, P5532 Dirt / Moisture Trap
P5531 Dirt / Moisture Trap Dirt / moisture traps provide an effective barrier against the transfer of moisture and dirt from an instrument under test to the sensitive piston/cylinder assembly of a pneumatic deadweight tester. Unexpected pa...
Код: P5531
Rotronic PC33 - Analog RH and Temperature Probe
The PC33 series offers a comprehensive range of relative humidity probes for accurate, stable and repeatable measurements. Available with analog output signals, the PC series can be installed in a wide variety of applications...
Код: PC33
Michell Easidew Sampler
Michell Easidew Sampler
A low-cost, self-contained sampling system, with filtration and flow control, for measurement of either pressure or atmospheric dew points...
Код: Easidew Sampler
Parallel Tube Liquid Bath Libra Model 785M
Parallel Tube Liquid Bath Libra Model 785M
Isotech calibration baths employ sophisticated designs to ensure calibration to the smallest of uncertainties. In 1986 Isotech purchased the interests of H N Irving & Sons Temperature division which had specialised in providing high quality...
Код: 785M
Rotronic PCMini52 - Digital RH Mini Probe with Temperature output
The micro processor control and multi-point calibration gives the PCMini52 RH probe excellent performance in terms of accuracy and linearity. The mini probe has two linear analog outputs for temperature and relative humidity...
Код: PCMini52
Blackbody Source Model 988
Blackbody Source Model 988
First introduced to assist in relation to the SARS outbreak during the early 2000s the Model 988 is now helping in relation to coronavirus. It can be used to increase the accuracy of thermal imagers being used to measure human skin temperat...
Код: 988
2456 WinPrompt Piston Gauge Monitor Software
WinPrompt Calibration Software WinPrompt calibration software increases calibration efficiency by providing full-color, Windows-based measurement for your process. This easyto-use software can be used independently or in conjunction with t...
Код: WinPrompt
microK Precision Thermometry Bridge
microK Precision Thermometry Bridge
The microK 70 and 125 models are designed for the Primary Temperature Laboratories whilst the microK 250 and 500 models were designed for the Secondary Laboratory as well as a wide range of high accuracy industrial and scientific calibratio...
3.0000/5 4text_more_review
Код: croK
Humidity Validator - Michell HygroCal100
Humidity Validator - Michell HygroCal100
The HygroCal100 provides a stable test chamber to quickly evaluate the performance of relative humidity sensors across a wide range of 5 to 95% relative humidity. Its intuitive 4” touch screen display and interface allows the probes under ...
Код: HygroCal100
P5544 Two Gauge Stand
This adapter mounts directly to the test port of the calibrator and allows for the calibration of two instruments at the same time, or the connection of a reference test instrument. Maximum working pressure is 10,000 psi (700 bar)...
Код: P5544
IO620-HOSE-P1 Pneumatic hose
IO620-HOSE-P1 Pneumatic hose
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Safe area use 1 m/3.28 ft pneumatic hose. Maximum pressure 400 bar/5800 psi...
Код: IO620-HOSE-P1
ADT151 Digital Pressure Module
ADT151 Digital Pressure Module
Additel’s 151 pressure modules have been designed with flexibility and efficiency in mind and can easily be swapped out as needed to meet changing needs and workloads. Higher pressure ADT151 modules cover two separate pressure ranges and co...
Код: ADT151
2468A Pitot/Static Primary Standard
2468A Pitot/Static Primary Standard
The Model 2468 Pitot Static Primary Standard is specifically designed for calibrating today’s high performance flight line and Air Data Test Systems. With the new autofloat controller, operator intervention is reduced to simply applying the...
Код: 2468A
Trace Moisture Transmitter - Michell Pura
Trace Moisture Transmitter - Michell Pura
This small transmitter is a rugged, self-contained hygrometer for the measurement of trace moisture content in ultra-high purity gases. Simple to use and install, the Pura is available in 2-wire, 3-wire and hazardous area versions and is f...
Код: Pura
P3800 Hydraulic Deadweight Testers
P3800 Hydraulic Deadweight Testers
The Pressurements P3800 Series is the culmination of over 50 years experience in the design and manufacture of primary pressure standards. With features and options designed to improve accuracy, increase reliability, and simplify operation,...
Код: P3800
4Sight2 Calibration Software
4Sight2 Calibration Software
4Sight2 Calibration software is a web-based calibration management tool that helps you maintain and control your calibration environment to the highest metrology standards. 4Sight2 from Druck, a Baker Hughes business, offers easy-to-use, co...
Код: 4Sight2
Amplifier and digital Modbus / USB converter for Rotronic HC2(A) probes
Amplifier and digital Modbus / USB converter for Rotronic HC2(A) probes
The HC2-A extension cables extend the HC2-A probes away from transmitters, handheld instruments or data loggers and data loggers. The HC2-A extension cables can be used up to 5 meters. For longer cable runs, use the AC3003 signal amplifier ...
Код: HC2(A)
Спасибо!