Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

GasPro – Mobile gas sampler

- Approved sample cylinder pressure: 4…8 bar abs.

- Pressure at GasPro: 4,5…8,5 bar overpressure 

- Max. Operating Pressure: 16 bar

- Sample cylinder volume: 500 ml

- Error limit for HS calorific value: 0,112 kWh/m³

  • GasPro – Mobile gas sampler
Brief specifications

Approved sample cylinder pressure: 4…8 bar abs.

Inlet pressure at GasPro: 4,5…8,5 bar overpressure (1,5 bar higher than the selected sample cylinder pressure)

Max. Operating Pressure: 16 bar

Temperature range: -20…+50 °C

Supply voltage: 230 VAC / optional 24 VDC

Sample cylinder volume: 500 ml

Error limit for HS calorific value  (including analysis): 0,112 kWh/m³

More details

GasPro – Mobile gas sampler

Representative cyclical gas sampling to determine gas quality in the gas network.

Analysing the gas quality in the gas network is essential to monitor technical specifications and ensure correct billing. The GasPro is a mobile gas sampler, with which cyclic sampling can be carried out easily and flexibly at any point from dry gas networks. The samples are collected in a sample cylinder in the GasPro and can then be analysed in a laboratory. The GasPro allows the separation of sampling and sample analysis and is therefore more cost effective and flexible than for example fixed installed gas chromatographs.

Applications

Natural gas quality
Assessment of natural gas quality with respect to corresponding regulations (e.g. DVGW) e.g. at network interconnection points and in supply areas with feed-in involving differing gas qualities.

SmartSim-validation
Validation of gas quality tracking systems (SmartSim) – comparison of simulated gas parameters with actual analysis values via GasPro samples.

Biogas quality
Determination of gas parameters at biogas plants.

Hydrogen quality
Determination of hydrogen purity.

Process gas quality
Determination of different process gas qualities
(available process gases on request).

Official calibration regulation of gas characteristics, PTB approval

GasPro is approved by PTB (Physikalisch Technische Bundesanstalt, Germany) for use in gas parameter custody transfer assessment, e.g. for validation of gas quality tracking systems. Due to the optimized gas sampling process with the GasPro the error limit of calorific value is HS = 0.112 kWh/m³ (including analysis).


ВимірюванняГенерація (Імітація)


GasPro – Mobile gas sampler

- Approved sample cylinder pressure: 4…8 bar abs.

- Pressure at GasPro: 4,5…8,5 bar overpressure 

- Max. Operating Pressure: 16 bar

- Sample cylinder volume: 500 ml

- Error limit for HS calorific value: 0,112 kWh/m³

Featured Products

Annealing Furnace
Annealing Furnace
Designed to pre-warm and anneal Standard Platinum Resistance Thermometers Maintenance Free Use Automatic Temperature Cycling The Annealing Furnace, model 414, is designed to heat, anneal and cool Standard Platinum Resistance Thermometers (S...
Код:
Calibration test benches for gas meters
Calibration test benches for gas meters
Calibration test bench for gas meters Calibration of domestic gas meters (G1,6…G400) The test bench is especially designed for the calibration of domestic gas meters (diaphragm gas meters, ultrasonic gas meters, thermoelectric gas met...
Код: CTB
Hydra Model 798M
Hydra Model 798M
Precision calibration of thermometers calls for the use of stirred liquid calibration baths. The Hydra models set new standards in terms of price to performance ratio. Now Calibration Engineers and Metrologists can choose from a range of ba...
Код: 798M
Oxygen Analyzer - Michell XTP601
Oxygen Analyzer - Michell XTP601
The XTP601 Oxygen Analyzer for safe or hazardous areas is a robust, linear and stable device that is used for measurements in gases such as biogas, methane, hydrogen, nitrogen or carbon dioxide. The analyzer meets the requirements of IEC615...
Код: XTP601
AII GPR-2600 Oxygen Analyzer
Our range of oxygen analyzers are designed to monitor gas produced or used in industrial processes where trace oxygen from low parts per million to pure O2 must be precisely measured. Utilizing AII’s high performance galvanic oxygen sensors...
Код: GPR-2600
CAL NotePad
CAL NotePad
The purpose of Cal NotePad (CNP) is to automatically log and display the temperature of an Isotech calibration bath together with the unit under test. Cal NotePad can be used with baths (or indicators) without PC interfaces by the user typi...
Код: ePad
Handheld Humidity Meters - Rotronic HYGROPALM HP31/HP32
HygroPalm HP31 Ideal handheld instrument for humidity and temperature measurement in simple applications. The integrated Hygromer IN-1 sensor guarantees accurate measuring results.   HygroPalm - HP32 - Versatile Handheld Instrument...
Код: HP31/HP32
AII GPR-1100 Portable PPM Oxygen Analyzer
Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in the...
Код: GPR-1100
P5544 Two Gauge Stand
This adapter mounts directly to the test port of the calibrator and allows for the calibration of two instruments at the same time, or the connection of a reference test instrument. Maximum working pressure is 10,000 psi (700 bar)...
Код: P5544
PACE1000 Precision Pressure Indicator
PACE1000 Precision Pressure Indicator
The Druck PACE1000 precision pressure indicator brings together the latest measurement technology to offer an elegant, fast, flexible and economical solution to pressure measurement for test, calibration and monitoring. PACE employs digital...
Код: PACE1000
5030 SERIES
5030 SERIES
GUILDLINE INSTRUMENTS 5030 SERIES are precision air baths providing uniform constant temperature over a range of operating environments. To improve measurements and reduce the uncertainty contribution from temperature effects, these high qu...
Код: 5030
Rotronic Service Cable
Rotronic Service Cable
Service cable for Rotronic Transmitters.Compatible with HF3/4/5/7/8, HL20D...
Код: Cabel
Rotronic CO2 Display for Indoor Air Quality Monitoring (CL11, CP11)
Rotronic CO2 Display for Indoor Air Quality Monitoring (CL11, CP11)
Indoor Air Quality (IAQ) measurements in offices, conference rooms, schools, etc. Application range: 0...50 °C / 0...95 %rh, non-condensing CO2 Measurement principle: Infrared (NDIR) with automatic calibration (ABC) CO2 Display Wal...
Код: CL11_ CP11
Cost Effective Humidity Validator - Michell S904
Cost Effective Humidity Validator - Michell S904
The S904 is a stand-alone and transportable humidity calibrator which is easy to use and maintain. The calibration chamber features 5 interchangeable ports to accommodate virtually any brand, type or model of humidity sensor. This calibrato...
Код: S904
Gallium Fixed Point Apparatus
Gallium Fixed Point Apparatus
Model 17402B Gallium Apparatus is not an adaptation from general purpose equipment, but is designed specifically to realize and maintain the Gallium Cell on the melt plateau, for calibration of thermometers on the International Temperature ...
Код:
786 Model
786 Model
Operate confidently in cold environments, even as low as -29°C. The ruggedly designed Model 786 takes laboratory level performance into the harshest of environments. Unlike other calibrators that cannot be used in the extreme cold, the 7...
Код: 786
Oberon R Model 426
Oberon R Model 426
The Oberon R uses a Sodium heat Pipe to ensure an exceptionally low temperature gradient along the furnace core. It is ideal for the realization of Aluminium, Silver or Copper ITS-90 Fixed Points. It may be used as a blackbody source over t...
Код: 427
Michell Condumax II and OptiPEAK TDL600 Dew-Point Analyzer
Michell Condumax II and OptiPEAK TDL600 Dew-Point Analyzer
Hydrocarbon dew point (HCDP) and moisture are key quality parameters to ensure the quality of pipeline transmission gas. With the combined Condumax II and OptiPEAK TDL600 analyzer system pipeline operators have the assurance of the most wid...
Код: TDL600 Dew-Point
Greybody Source Model 975
Greybody Source Model 975
When the high accuracy of the Gemini R is not necessary this product offers a cost effective solution for the calibration and testing of infrared thermometers. The Greybody Model 975 gives fast accurate results with a larger sensing area. A...
Код: 975
ADT919A Pneumatic Pressure Test Pump
ADT919A Pneumatic Pressure Test Pump
The 919A High Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 2,000 psi (140 bar). With a long lever, it just takes 30 seconds to reach 2,000 psi (140 bar). A high-quality screw press is ...
Код: ADT919A
Спасибо!