AII GPR-2000 Portable Oxygen Analyzer

-Accuracy: < 2% of FS range under constant conditions

Analysis Ranges: 0-1%, 0-5%, 0-10%, 0-25% FS Auto-ranging or manual lock on a single range

Application: Oxygen analysis in inert, helium, hydrogen, mixed and acid (CO2) gas streams

Area Classification: General purpose or Class I, Division 1, Groups C, D (Certified for use hazardous areas)

Not flow sensitive

Pressure: Inlet - regulate to 5-30 psig to deliver 2 SCFH flow;

vent – atmospheric

Power: Rechargeable battery, 60 day cycle, 8 hrs with pump

Sample System: None; optional integral sample pump and panel mounted flow meter and/or coalescing filter

Sensitivity: < 0.5% of FS range

Sensor Model: GPR for non-acid (CO2) gas streams, XLT for gas mixture with > 0.5% CO2

Temp. Range: 5º to 45ºC (GPR sensor), -10º to 45ºC (XLT sensor)

Wetted Parts: Brass, plastic or Stainless steel flow housing, tubing and fittings

Brief specifications


More details

Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in their reliability and accuracy.

 

The Analytical Instruments concept of using the same HMI and menu structures for portable and online analyzers makes it extremely easy for operators to use both types of instruments on their site without need for extra training.


ВимірюванняГенерація (Імітація)


AII GPR-2000 Portable Oxygen Analyzer

-Accuracy: < 2% of FS range under constant conditions

Analysis Ranges: 0-1%, 0-5%, 0-10%, 0-25% FS Auto-ranging or manual lock on a single range

Application: Oxygen analysis in inert, helium, hydrogen, mixed and acid (CO2) gas streams

Area Classification: General purpose or Class I, Division 1, Groups C, D (Certified for use hazardous areas)

Not flow sensitive

Pressure: Inlet - regulate to 5-30 psig to deliver 2 SCFH flow;

vent – atmospheric

Power: Rechargeable battery, 60 day cycle, 8 hrs with pump

Sample System: None; optional integral sample pump and panel mounted flow meter and/or coalescing filter

Sensitivity: < 0.5% of FS range

Sensor Model: GPR for non-acid (CO2) gas streams, XLT for gas mixture with > 0.5% CO2

Temp. Range: 5º to 45ºC (GPR sensor), -10º to 45ºC (XLT sensor)

Wetted Parts: Brass, plastic or Stainless steel flow housing, tubing and fittings

Featured Products

Dew-Point Hygrometer - Michell Cermet II
A full specification on-line hygrometer for the measurement of dew point in air and process gases, with wide operating range and multiple display options...
Код: Cermet II
PV411A Combined Test Pump
PV411A Combined Test Pump
The PV411A is a high-quality field proven pressure and vacuum hand pump providing functionality, which has never been seen before in a handheld pressure source. This remarkable product replaces four conventional hand pumps and offers the...
Код: PV411A
High Precision Chilled Mirror Hygrometer - Michell S8000 RS
High Precision Chilled Mirror Hygrometer - Michell S8000 RS
The S8000 RS is a high-precision chilled mirror reference hygrometer which gives highly accurate and repeatable measurements of dew-point and humidity. It is intended for use as a reference instrument in standards laboratories and is also s...
Код: S8000 RS
SMF – Calibration system for flow measurement of air and other gases
SMF® – SonicMasterFlow® Highly precise flow measurement of gases and air The SMF® – SonicMasterFlow® series are calibration systems for high-precision flow measurement of air and other gases (optional) (volume and mass flows) using cr...
Код: SMF
DххP Pneumatic Cylinder Hand Pump
DххP Pneumatic Cylinder Hand Pump
An economical solution for low-pressure applications, we offer three cylinder hand pump options with a modular design that makes field maintenance quick and easy. Our DP0V model provides reliable test pressure up to 125 psi (860 kPa), the D...
Код: DxxP
IO620-104ADAPT DPI 104 gauge adaptor
IO620-104ADAPT DPI 104 gauge adaptor
DPI 104 Gauge adaptor Allows a DPI 104 digital pressure gauge to be connected to the PV62XG pressure module port in place of DPI620G and PM620 to provide a simple low cost pressure calibrator...
Код: IO620-104ADAPT
IOHOSE-NP1 Pneumatic hose
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Safe area use 1 m/3.28 ft pneumatic hose. Maximum pressure 20 bar/300 psi...
Код: IOHOSE-NP1
Clean Room Panel Rotronic CRP5
Clean Room Panel Rotronic CRP5
The CRP5 clean-room panel is the obvious choice wherever a high degree of cleanliness is vital, in addition to precise measurement of differential pressure, humidity, and temperature. The CRP5 is used particularly in clean-rooms in hospital...
Код: CRP5
AII GPR-1200 MS-2 Premium Portable PPM Oxygen Analyzer
GPR-1200 MS-2 (ATEX) Designed for spot-checking ultra-high purity gases, the GPR-1200 MS-2 has a range of 0-1 ppm and LDL of 5 ppb O2 – the lowest oxygen measurements available with a portable instrument. ATEX-approved version available...
Код: GPR-1200
AII GPR-1000 Portable PPM Oxygen Analyzer
Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in the...
Код: GPR-1000
AII GPR-2000 Portable Oxygen Analyzer
AII GPR-2000 Portable Oxygen Analyzer
Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in the...
Код: GPR-2000
ADTS553F Air data test system
ADTS553F Air data test system
The ADTS553F air data test set is a portable three-channel flightline pitot static tester. It provides pitot static air data validation, leak testing, fault-finding and avionics instrumentation testing for any aircraft requiring angle of at...
Код: ADTS553F
Copper Point SPRT Model 108462
Copper Point SPRT Model 108462
The ITS-90 specifies the SPRT to the freezing point of silver, 961.78°C. Thermocouples can be used beyond this temperature but it is difficult to see small changes in temperature. For a Type R thermocouple the voltage sensitivity at the cop...
Код: 8462
Dew-Point Transmitter - Michell Easidew EA2
Dew-Point Transmitter - Michell Easidew EA2
The Easidew sensor is a moisture meter that measures both dew point and moisture content. It is simple to install as it is available with a wide range of process connections and electrical connectors. All Easidew dew-point transmitters are ...
Код: EA2
H8000 Relative Humidity Element
The H8000 capacitive polymer element is the latest generation technology, developed to reliably and accurately measure moisture in a wide range of relative humidity applications. This element is the core measurement element of Michell’s ne...
Код: H8000
AII GPR-3500 MO Portable Oxygen PurityAnalyzer
The GPR-3500MO is supplied with panel mounted flow meter for maximum portability...
Код: GPR-3500
Rail Dew-Point Transmitter - Michell SF72 Rail
Rail Dew-Point Transmitter - Michell SF72 Rail
A cost-effective moisture transmitter designed to continuously monitor the performance of the compressed air dryers on railway rolling stock to ensure the safety and efficiency of braking and other systems. Using Michell’s latest generatio...
Код: SF72 Rail
AII GPR-1100 Portable PPM Oxygen Analyzer
Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in the...
Код: GPR-1100
Additel 875-1210 Thermocouple Calibration Furnaces
Additel 875-1210 Thermocouple Calibration Furnaces
We understand the many challenges associated with thermocouple calibration work. That is precisely why we decided to introduce the ADT875-1210 and ADT878-1210 Thermocouple Calibration Furnaces. With an unmatched stability, uniformity and an...
Код: ADT878-1210
Water Triple Point Maintenance Bath
This dedicated apparatus has more than 35 years of proven use and is widely used by the worlds’ leading NMIs. In a recent International study cells from 21 of the world’s leading laboratories were inter-compared; the study used two Isotech ...
Код: Water Triple