Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

AII GPR-35 Ambient Oxygen Monitors

-Accuracy: < 2% of reading under constant conditions

Analysis: 0-25% FS ranges

Application: Monitor oxygen content of ambient atmospheres or confined spaces where oxygen depletion is a concern

Area Classification: General purpose (Category, II; pollution degree, 2)

Flow: Sampling - not applicable to ambient monitoring

Power: 100/110/220/240 VAC with fluctuation not to exceed +10%; battery back-up on trickle charge; battery life 30 days normal mode or 8 hours in alarm mode

Operating Range: 0º to 45ºC

Alarms: Two adjustable SPDT Form C non-latching relay contacts, preset to OHSA 20.0% Caution, 19.5% Danger settings

  • AII GPR-35 Ambient Oxygen Monitors
Brief specifications


More details

0-25% FS ranges

Accuracy < 2% of range at constant conditions

Advanced Sensor Technology:

• Long Life Sensor, Low maintenance with typically 32 months oxygen sensor life

• Extended Operating Range

• Sensitivity 0.5% Full Scale

No False Alarms - Pressure Compensated

Mains power with battery back-up (8 Hrs in Alarm Mode)

Dual Red-Green LED Alarm Indicators

Optional: 4-20mA Output, Integral Pump, Audible & Visual Alerts


ВимірюванняГенерація (Імітація)


AII GPR-35 Ambient Oxygen Monitors

-Accuracy: < 2% of reading under constant conditions

Analysis: 0-25% FS ranges

Application: Monitor oxygen content of ambient atmospheres or confined spaces where oxygen depletion is a concern

Area Classification: General purpose (Category, II; pollution degree, 2)

Flow: Sampling - not applicable to ambient monitoring

Power: 100/110/220/240 VAC with fluctuation not to exceed +10%; battery back-up on trickle charge; battery life 30 days normal mode or 8 hours in alarm mode

Operating Range: 0º to 45ºC

Alarms: Two adjustable SPDT Form C non-latching relay contacts, preset to OHSA 20.0% Caution, 19.5% Danger settings

Featured Products

Heavy Duty Transmitter Temperature and Humidity - Rotronic HF73A
Heavy Duty Transmitter Temperature and Humidity - Rotronic HF73A
The HF73A transmitter series is designed for fixed installation in industrial applications where conditions are within the range of 0 to 100 %rh and -100 to 150 °C (-148 to 302 °F). The probe of the HF73A can survive exposure to temperature...
Код: HF73A
7334 Series of AC/DC Air Resistance Standards
7334 Series of AC/DC Air Resistance Standards
Guildline Instruments 7334 Series of AC/DC Air Resistance Standards are designed for high accuracy resistance calibration in air, without the need for stabilization in a temperature controlled bath. PRODUCT FEATURES Typical AC/DC Error ...
Код: 7334
Portable Dew-Point Tester – Michell CDP301
Portable Dew-Point Tester – Michell CDP301
CDP301 portable HCDP tester uses the chilled mirror principle for both hydrocarbon and water dew point measurements and is designed to follow the requirements as described in ASTM D1142. Based on the visual manual method of observing the fo...
Код: CDP301
Cyclops Model 878
Cyclops Model 878
The Cyclops Model 878 is a spherical blackbody source. It consists of an inner black sphere that sits inside a spherical furnace and is suitable for use as a radiation source for infrared thermometers. The inner sphere has a nominal diamete...
4.0000/5 2text_more_review
Код: 879
CAL NotePad
CAL NotePad
The purpose of Cal NotePad (CNP) is to automatically log and display the temperature of an Isotech calibration bath together with the unit under test. Cal NotePad can be used with baths (or indicators) without PC interfaces by the user typi...
Код: ePad
microK Gold
microK Gold
microK GOLD – a unique package Best performance, documented, guaranteed with an unmatched satisfaction promise. Award Winning In April 2017 Isotech won a Queen’s Award for Enterprise in the Innovation category for the co-development of the ...
Код: Gold
Medium Temperature Furnace
Medium Temperature Furnace
Whilst heat pipe furnaces offer the ideal environment to melt and freeze ITS-90 Fixed Points the temperature range is limited by fluid that flows inside the pipe. Three zone furnaces can offer wider operating ranges and still meet the requi...
Код:
GasPro – Mobile gas sampler
GasPro – Mobile gas sampler Representative cyclical gas sampling to determine gas quality in the gas network. Analysing the gas quality in the gas network is essential to monitor technical specifications and ensure correct billing. Th...
Код: GasPro
Electricity Meter Test Equipment ELMA 8x01
The accuracy of the power and energy reference meter is available up to 0.01 %. The reference meter measures all main and influencing quantities inclusive harmonic analysis and distortion of the test signals. The available power and the max...
Код: ELMA 8x01
Miniature Fixed Resistor Model 836
Isotech produces a miniature resistor with ultra-low temperature coefficient and ultra-high stability. This is achieved because the resistors are oil filled and hermetically sealed. The function of hermetic sealing is to eliminate the ingre...
Код: 836
6625A is the only true modular Resistance and Current Measurement System
6625A is the only true modular Resistance and Current Measurement System
Guildline Instruments 6625A is the only true modular Resistance and Current Measurement System providing users with unique industry leading features and capabilities. PRODUCT FEATURES Complete Turn-Key System – Fully Integrated, Wired, Test...
Код: 6625A
millisKanner Channel Expander
millisKanner Channel Expander
The millisKanner channel expander has eight input channels, and each can be configured individually for SPRT, PRT, Thermistor or Thermocouple input. This gives ultimate flexibility with no need for separate devices for resistance or thermoc...
Код:
QuickCal Blackbody
QuickCal Blackbody
When the high accuracy of the Gemini R is not necessary this product offers a cost effective solution for the calibration and testing of infrared thermometers. The QuickCal Blackbody is ideal for rapid and portable checking of infrared ther...
4.8182/5 11text_less_review
Код: QuickCal Blackbody
POTTS – Europa-6 Model 520
POTTS – Europa-6 Model 520
The multi-functions of the Europa-6 is a unique award winning concept from Isotech. The Europa-6 is a complete calibration laboratory working over the temperature range 65°C below ambient temperature to +140°C. It permits the calibration of...
Код: 520
700HPPK Pneumatic Test Pump
700HPPK Pneumatic Test Pump
The Fluke Calibration 700HPPK Pneumatic Test Pump Kit generates and adjusts pneumatic pressures up to 21 MPa (3000 psi), without requiring a nitrogen bottle or other external pressure supply. It supplies pressure to devices under test (DUTs...
Код: 700HPPK
DPI800/802 Pressure Indicator /Loop Calibrator
DPI800/802 Pressure Indicator /Loop Calibrator
DPI 800/802 Druck Pressure Indicator/Loop Calibrator The DPI 800 Series is a complete range of advanced, robust and simple to use hand-held instruments. Highly cost effective, these tools are ideal for test/calibration of many popular proce...
Код: DPI800/802
9050A transportable multiproduct calibrator
9050A transportable multiproduct calibrator
The 9000A series range of multiproduct calibrators offers the widest workload of any calibration system presently available. The 9000A series provides all of the functionality of the 3000A series multiproduct calibrator in a dedicated rugge...
4.0000/5 1text_less_review
Код: 9050A
6664C LOW THERMAL QUAD CHANNEL SCANNERS
6664C LOW THERMAL QUAD CHANNEL SCANNERS
THE 6664C LOW THERMAL QUAD CHANNEL SCANNERS ENABLES SOFTWARE CONTROLLED, FULLY AUTOMATED NORMAL AND HIGH OHM MEASUREMENTS WITH VOLTAGES UP TO 1000 V PRODUCT FEATURES Withstands up to 1000 Vdc to provide fully automated resistance measuremen...
Код: 6664C
Dual and Heat Pipe Furnaces
Dual and Heat Pipe Furnaces
Heat Pipe Furnaces Isotech metrology furnaces have more than 35 years of proven use and are widely used by the worlds’ leading NMIs. For the optimal use of fixed point cells the temperature uniformity should be less than 10mK over the lengt...
Код:
RH and Temperature Probe Calibrator - Rotronic HygroGen 2
RH and Temperature Probe Calibrator - Rotronic HygroGen 2
The HygroGen2 is a generator of controlled relative humidity and temperature environments, primarily for use in calibrating humidity instrumentation, but is also well suited to the calibration of temperature instrumentation, particularly ...
Код: HG2
Спасибо!