Dew-Point Hygrometer - Michell SF82 Online
- Quick to Install Hygrometer System
- Features
-
- Measurement range -60 to +60 °C dew point
- Accuracy ±2 °C dew point
- 4 to 20 mA output
- Modbus RTU over RS485 output
- Dual configurable alarm outputs
- Sample block and cable included
- Traceable 9-point calibration certificate
- Ultra-fast response to moisture change
- Fast Response Moisture Meter with Multiple Process Connections.
- Features
-
- Dew point or ppmV moisture content output
- Accuracy ±2 °C dew point
- Modbus RTU over RS485 digital communication
- 4 to 20 mA 2 wire
- Traceable 9-point calibration certificate
- Power supply 5 to 28 V DC
- Ultra-fast response to moisture change
- Low cost of ownership and easy maintenance with sensor exchange program
- 316 stainless steel sensor and sample blocks
- 5/8” UNF, 3/4” UNF, G 1/2” process connections
- KF40 Glove Box flange
- MiniDIN 43650 C, M12 electrical connectors
HygroSmart HS3 Relative Humidity and Temperature Probe
- Accuracy ±0.8% RH
- Output Signals 0 to 1, 2.5, 5, 10 V & Modbus RTU over RS485
- Power supply 5 to 28 V
- Probe diameter ø15mm
- 100% end-user configurable
- Interchangeable sensor for rapid maintenance
- Traceable 5 point calibration certificate
Rotronic PCMini52 - Digital RH Mini Probe with Temperature output
-Accuracy: ±2 %rh (10...90 %rh), ±0.2 K @ 23 °C
Application range: 0…100 %rh, -20…80 °C
Stability: ±1 %rh/year
Output signal: Modbus RTU 0 to 1, 0 to 5, 0 to 10 V
Power supply: 14…35 VDC (0…5 V/0…10 V output) 6…35 VDC (0…1 V output)
Dew-Point Hygrometer - Easidew Advanced Online
Measurement range: -110...+20 °C dew point
Accuracy: ±1 °C from -60 to +20 °C dew point
±2°C from -100 to -60 °C dew point
Operating Pressure: 45 MPa (450 barg/6527 psig)
Sensor Input Signal: Modbus RTU over RS485
Output Signals: 3 x 4...20 mA channels; Modbus RTU over RS485; 4 programmable relay alarms
Sensor Flow Rate: 1...5 Nl/min mounted in standard sampling block; 0...10 m/sec direct insertion
Dew-Point Hygrometer - Michell Cermet II
- For Pressure-Compensated Dew-Point Measurement
- Features
-
- Wide measurement range, calibrated -100 to +20°C (-148 to +68°F) dew point
- ±1.0°C (±1.8°F) dew-point measurement accuracy
- Analog and digital output
- Pressure sensor input
- Up to 4 alarm relays
- User-selectable measurement units
- Easy to read display
Dew-Point Hygrometer - Michell Easidew Online
- Moisture Measurement with Configurable Display
- Features
-
- Measurement range -100 to +20 °C (-148 to +68 °F) dew point
- Dew point or ppmV moisture content output
- Accuracy ±2 °C (±3.6 °F) dew point
- 4 to 20 mA output
- Modbus RTU over RS485 output
- Dual configurable alarm outputs
- Choice of AC or DC Power Supply
- Sample block and cable included
- Traceable 13-point calibration certificate
Dew-Point Transmitter - Michell Easidew 34
- Moisture Measurement for Compressed Air Dryers
- Features
-
- 3/4” UNF process connection
- Measurement ranges -110 up to +20°Cdp (-148 up to +68°Fdp)
- Dew point or ppmV moisture content output
- 2-wire loop power connection
- Accuracy ±2 °Cdp (±3.6°Fdp)
- Traceable calibration certificate
- Low cost of ownership and easy maintenance with sensor exchange program
- 316 Stainless steel sensor and sample blocks
- KF40 Glove Box flange
- MiniDIN 43650, M12 electrical connectors
- Oxygen service cleaned
Dew-Point Transmitter - Michell Easidew EA2
- Moisture Transmitter for Safe and Hazardous Areas
- Features
-
- Measurement ranges -110 up to +20°Cdp
- Dew point or ppmV moisture content output
- 2-wire loop power connection
- Accuracy ±2 °Cdp
- Traceable calibration certificate
- Easidew I.S. IECEx, cCSAus, FM and ATEX approvals
- Low cost of ownership and easy maintenance with sensor exchange program
- 316 Stainless steel sensor and sample blocks
- 5/8” UNF, 3/4” UNF, G 1/2” process connections
- KF40 Glove Box flange
- MiniDIN 43650, M12 electrical connectors
- Oxygen Service cleaned
- Cost-Effective Moisture Measurement in Harsh Applications
- Features
-
- Ideal for OEM dryer use
- Dew-point measurement range -40 to +60 °C (-40 to +140 °F)
- Fast response
- Rugged IP65 construction
- 3-Point traceable calibration certificate
- Accuracy ±2°C (±3.6°F)
- Voltage or mA outputs
Explosion Proof Moisture Transmitter - Easidew PRO XP
- Reliable Analysis of Dew-Point or Moisture Content in Gases and Liquids
- Features
-
- Measurement ranges -110 up to +20°Cdp (-166 to 68°Fdp)
- Global explosion / flameproof certification
- Accuracy ±1°Cdp (±1.8°Fdp)
- 2-wire 4-20 mA output
- Traceable 13-point calibration certificate
- 450 bar (6527 psi) pressure rating
- Low cost of ownership and easy maintenance with sensor
- exchange program
- 3/4” UNF industry standard process connection
- EN 10204 3.1 material certification
- Moisture in gases and liquids
- Integral display meter
- Oxygen service cleaned
H8000 Relative Humidity Element
- Linearity ±1.5% RH
- Stability ±1% RH per year
- Operating temperature –40 to +200°C
- Low thermal hysteresis
- ø0.4mm leg diameter
- Nominal capacitance 250 pF
- Low RH hysteresis

-350x280.jpg)