Categories
-
Pressure
-
Temperature
-
Humidity
-
Electrical signals
- Calibrator of electrical signals
- Reference multimeters
- Voltage, resistance, frequency standards
- Precision bridges
- Teraohmmeter
- Reference electricity meters
- Installations for verification of electricity meters
- Power analyzers
- Voltage dividers
- Current shunts
- Precision current transformers
- Systems for measuring current
- Precision measuring systems
- Test Equipment
- Liquid and air baths for resistance measures
- Standards of conductivity (salinity)
- Software
- Accessories
- Multifunction calibrators
-
Flow measurement
-
Chemical composition
-
Complex solutions
-
Services
Dew-Point Hygrometer - Michell SF82 Online
- Quick to Install Hygrometer System
- Features
-
- Measurement range -60 to +60 °C dew point
- Accuracy ±2 °C dew point
- 4 to 20 mA output
- Modbus RTU over RS485 output
- Dual configurable alarm outputs
- Sample block and cable included
- Traceable 9-point calibration certificate
- Ultra-fast response to moisture change
- Fast Response Moisture Meter with Multiple Process Connections.
- Features
-
- Dew point or ppmV moisture content output
- Accuracy ±2 °C dew point
- Modbus RTU over RS485 digital communication
- 4 to 20 mA 2 wire
- Traceable 9-point calibration certificate
- Power supply 5 to 28 V DC
- Ultra-fast response to moisture change
- Low cost of ownership and easy maintenance with sensor exchange program
- 316 stainless steel sensor and sample blocks
- 5/8” UNF, 3/4” UNF, G 1/2” process connections
- KF40 Glove Box flange
- MiniDIN 43650 C, M12 electrical connectors
HygroSmart HS3 Relative Humidity and Temperature Probe
- Accuracy ±0.8% RH
- Output Signals 0 to 1, 2.5, 5, 10 V & Modbus RTU over RS485
- Power supply 5 to 28 V
- Probe diameter ø15mm
- 100% end-user configurable
- Interchangeable sensor for rapid maintenance
- Traceable 5 point calibration certificate
Rotronic PCMini52 - Digital RH Mini Probe with Temperature output
-Accuracy: ±2 %rh (10...90 %rh), ±0.2 K @ 23 °C
Application range: 0…100 %rh, -20…80 °C
Stability: ±1 %rh/year
Output signal: Modbus RTU 0 to 1, 0 to 5, 0 to 10 V
Power supply: 14…35 VDC (0…5 V/0…10 V output) 6…35 VDC (0…1 V output)
Dew-Point Hygrometer - Easidew Advanced Online
Measurement range: -110...+20 °C dew point
Accuracy: ±1 °C from -60 to +20 °C dew point
±2°C from -100 to -60 °C dew point
Operating Pressure: 45 MPa (450 barg/6527 psig)
Sensor Input Signal: Modbus RTU over RS485
Output Signals: 3 x 4...20 mA channels; Modbus RTU over RS485; 4 programmable relay alarms
Sensor Flow Rate: 1...5 Nl/min mounted in standard sampling block; 0...10 m/sec direct insertion
Dew-Point Hygrometer - Michell Cermet II
- For Pressure-Compensated Dew-Point Measurement
- Features
-
- Wide measurement range, calibrated -100 to +20°C (-148 to +68°F) dew point
- ±1.0°C (±1.8°F) dew-point measurement accuracy
- Analog and digital output
- Pressure sensor input
- Up to 4 alarm relays
- User-selectable measurement units
- Easy to read display
Dew-Point Hygrometer - Michell Easidew Online
- Moisture Measurement with Configurable Display
- Features
-
- Measurement range -100 to +20 °C (-148 to +68 °F) dew point
- Dew point or ppmV moisture content output
- Accuracy ±2 °C (±3.6 °F) dew point
- 4 to 20 mA output
- Modbus RTU over RS485 output
- Dual configurable alarm outputs
- Choice of AC or DC Power Supply
- Sample block and cable included
- Traceable 13-point calibration certificate
Dew-Point Transmitter - Michell Easidew 34
- Moisture Measurement for Compressed Air Dryers
- Features
-
- 3/4” UNF process connection
- Measurement ranges -110 up to +20°Cdp (-148 up to +68°Fdp)
- Dew point or ppmV moisture content output
- 2-wire loop power connection
- Accuracy ±2 °Cdp (±3.6°Fdp)
- Traceable calibration certificate
- Low cost of ownership and easy maintenance with sensor exchange program
- 316 Stainless steel sensor and sample blocks
- KF40 Glove Box flange
- MiniDIN 43650, M12 electrical connectors
- Oxygen service cleaned
Dew-Point Transmitter - Michell Easidew EA2
- Moisture Transmitter for Safe and Hazardous Areas
- Features
-
- Measurement ranges -110 up to +20°Cdp
- Dew point or ppmV moisture content output
- 2-wire loop power connection
- Accuracy ±2 °Cdp
- Traceable calibration certificate
- Easidew I.S. IECEx, cCSAus, FM and ATEX approvals
- Low cost of ownership and easy maintenance with sensor exchange program
- 316 Stainless steel sensor and sample blocks
- 5/8” UNF, 3/4” UNF, G 1/2” process connections
- KF40 Glove Box flange
- MiniDIN 43650, M12 electrical connectors
- Oxygen Service cleaned
- Cost-Effective Moisture Measurement in Harsh Applications
- Features
-
- Ideal for OEM dryer use
- Dew-point measurement range -40 to +60 °C (-40 to +140 °F)
- Fast response
- Rugged IP65 construction
- 3-Point traceable calibration certificate
- Accuracy ±2°C (±3.6°F)
- Voltage or mA outputs
Explosion Proof Moisture Transmitter - Easidew PRO XP
- Reliable Analysis of Dew-Point or Moisture Content in Gases and Liquids
- Features
-
- Measurement ranges -110 up to +20°Cdp (-166 to 68°Fdp)
- Global explosion / flameproof certification
- Accuracy ±1°Cdp (±1.8°Fdp)
- 2-wire 4-20 mA output
- Traceable 13-point calibration certificate
- 450 bar (6527 psi) pressure rating
- Low cost of ownership and easy maintenance with sensor
- exchange program
- 3/4” UNF industry standard process connection
- EN 10204 3.1 material certification
- Moisture in gases and liquids
- Integral display meter
- Oxygen service cleaned
H8000 Relative Humidity Element
- Linearity ±1.5% RH
- Stability ±1% RH per year
- Operating temperature –40 to +200°C
- Low thermal hysteresis
- ø0.4mm leg diameter
- Nominal capacitance 250 pF
- Low RH hysteresis
Heavy Duty Transmitter Temperature and Humidity - Rotronic HF73A
-Measurement range: -100…200 °C1 / 0…100 %rh
Accuracy: ± 1.0 %rH
Electronics operating range: -40…85 °C / 0…100 %rh
Output signals (analog): 0...1 V, 0...5 V, 0...10 V, 0(4)...20 mA
Power supply: 15… 40 VDC / 12 …28 VAC
Humidity and temperature transmitter DT722
-Measurement range (RH): 0...100 %rh
Measurement range (T) -40...150 °C
Accuracy @ 25 °C: humidity < ±2 %rh (5...95 %rh); temperature ±0.2 °C
Operating temperatures: Probe -40...150°C; Housing -20...70°C
Stability – RH sensor ±1 %rh/year
Humidity Temperature Probes - Rotronic HC2-HK/C
-Accuracy at 23°C: ±0.8 %RH, ±1.5 %RH
Humidity measuring range: 0…100 %RH
Temperature limits: -40…85 °C/ -100…200°C
Output Signal: Digital UART / 2x 0…1 VDC
Dimension Measurement Head: Ø 15 x 250 mm / Ø 15 x 400 mm/ Ø 4 x 57 mm / Ø 5 x 51 mm
Humidity Temperature Probes - Rotronic HC2A-IC/IM/IE
-Accuracy @23°C: ±0,8 %RH ±0,1 K
Operating humidity 0…100 %RH
Operating temperature -50…+100°C2 Electronics
-100…200°C1 Measuring head
Long-term stability: < 1 %RH/year
Protocols RoASCII (default) MODBUS (setting with HW4)
Humidity Temperature Probes - Rotronic HC2A-S/S3/SM
-Accuracy @23°C: ±0.8 %rh ±0.1 K
Application Range: -50..100°C; 0...100 %RH
Long term stability: <1%RH/year
Protocols: RoASCII (Default); MODBUS (setting with HW4)
Filter: Polyethylen, 40 μm; Wire mesh, 10 µm
Humidity Temperature Probes - Rotronic HC2A-SH/S3H
-Accuracy @23°C: ±0.5 %rh ±0.1 K
Application Range: -50..100°C; 0...100 %RH
Long term stability: <1%RH/year
Protocols: RoASCII (Default); MODBUS (setting with HW4)
Filter: Polyethylen, 40 μm
Interchangeable Humidity and Temperature Sensor - Michell HygroSmart I7000XP Series
- Compact Sensor Modul
- Features
-
- Range of application -40…85 °C / 0…100 %RH
- Accuracy: ±1 %RH (5…95 % RH), ±0.2 K
- HygroSmart 3 technology
Intrinsically Safe Dew-Point Transmitter - Easidew I.S.
- Moisture Measurement in Hazardous Areas
- Features
-
- Measurement ranges -110 up to +20°Cdp
- Dew point or ppmV moisture content output
- 2-wire loop power connection
- Accuracy ±2 °Cdp
- Traceable calibration certificate
- Easidew I.S. IECEx, cCSAus, FM and ATEX approvals
- Low cost of ownership and easy maintenance with sensor exchange program
- 316 Stainless steel sensor and sample blocks
- 5/8” UNF, 3/4” UNF, G 1/2” process connections
- KF40 Glove box flange
- Oxygen service cleaned
Intrinsically safe dew-point transmitter - Michell Easidew PRO I.S.
- Intrisically Safe Dew-Point Measurement in Hazardous Areas
- Features
-
- Measurement range –110 to +20°Cdp
- ATEX, IECEx, cCSAus, FM, TC TR Ex certified
- Accuracy ±1°Cdp
- 2-wire 4–20 mA output
- Traceable 13-point calibration certificate
- 450 barg pressure rating
- Alternative process connections available
- Material certification to BS EN 10204 3.1
- Moisture in gases and liquids
- Service exchange program
- Oxygen Service cleaned
Meteo Transmitter for HC2A-S3 - Rotronic MP102H/402H
-Measuring Range: -50…100°C
Operating Range: -40…80 °C
Accuracy at 23°C: ±0.8 %RH / ± 0.1 K (typically value), probe dependent
Power Supply: 5…24 VDC/15…24 VDC
Output Signals: 0…1/5/10 VDC; 0(4)…20 mA
Meteorology RH and T Probes - Rotronic MP100A/MP400A
-Measurement range: 0..100 %RH
Accuracy at 0...30 °C: 10…95 %RH: ±1.5 %RH
Measurement range: -50...100 °C
Accuracy at 0...30 °C: ±0.3 K
Range of application: -40...85 °C

-350x280.jpg)
-350x280.jpg)





-350x280.jpeg)