Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

Orion Model 796M

- -80°C to 300°C, 470mm Immersion.

- The Isotech Hydra range of calibration baths have proved very successful since their introduction in 2003. These deep stirred liquid baths are suitable for the low uncertainty calibration of long thermometers including liquid in glass and extended length SPRTS.

- Can accept large Water Triple Point Cells

- Variable Cooling Power

- Low Filling Cost

Brief specifications


More details

The Isotech Hydra range of calibration baths have proved very successful since their introduction in 2003. The Orion range has been introduced to fit alongside the Hydra models. The Orion calibration baths offer deeper calibration volumes than the Isotech Hydra series with world class temperature stability. There is a high temperature model (30°C to 300°C) and a model with built in refrigeration (-40°C to 125°C). These deep stirred liquid baths are suitable for the low uncertainty calibration of long thermometers including liquid in glass and extended length SPRTS. The Orion unit has sufficient depth, 470mm (18.5”), to accommodate Isotech’s largest Water Triple Point Cells providing a cost effective sub mK calibration system. There are accessories to hold Mercury, Water, Gallium and Indium ITS-90 Fixed Point Cells. Isotech baths have always been designed for thermometer calibration, setting the standard for immersion depth versus filling costs. As the Orion requires just 8.5L of fluid it offers significant cost savings, both initial and the ongoing running costs, when compared to other larger volume baths. In operation the liquid level is within 10mm of the top lid allowing calibration of liquid in glass thermometers without the need for complicated accessories. In addition to using a monocular to aid reading the scale I-Cal Easy automatic calibration software can capture images with low cost digital webcams. The Isotech Orion range provides many features that laboratories need but which other manufacturers often cannot supply.


ВимірюванняГенерація (Імітація)


Orion Model 796M

- -80°C to 300°C, 470mm Immersion.

- The Isotech Hydra range of calibration baths have proved very successful since their introduction in 2003. These deep stirred liquid baths are suitable for the low uncertainty calibration of long thermometers including liquid in glass and extended length SPRTS.

- Can accept large Water Triple Point Cells

- Variable Cooling Power

- Low Filling Cost

Featured Products

DPI611 Handheld Pressure Calibrator
DPI611 Handheld Pressure Calibrator
Druck DPI611 is a portable pressure calibrator that provides accuracy, reliability and ease of use. It combines a compact design with high performance, making it the ideal choice for calibration professionals. This calibrator is capable ...
Код: DPI 611
P5513 Pneumatic Comparator
P5513 Pneumatic Comparator
This pneumatic comparison pressure comparator is designed for testing pressure measuring instruments against master test instruments. This cost effective instrument provides precise control for important calibration requirements and includ...
Код: P5513
Portable Hygrometer - Michell Easidew Portable
Portable Hygrometer - Michell Easidew Portable
Simple to use and rugged, the Easidew portable hygrometer is the ideal tool for a wide range of on-site maintenance spot checks and dry dew-point online measurements. The robust integral sample system and wide measurement range ceramic meta...
Код: Easidew Portable
ADT161 Intelligent Digital Pressure Modules
ADT161 Intelligent Digital Pressure Modules
With advanced microprocessor technology and state-of-the-art silicon pressure sensors, Additel’s 161 and 161Ex series Digital Pressure Modules provide an accurate, reliable, and economic solution for wide range of pressure applications. Our...
Код: ADT161
Isorac Model 844
Isorac Model 844
The function of this reference unit differs from other rack mounted systems in that the temperature of the metal block in which the thermocouple and copper leads are inserted actually varies with ambient temperature. A separate output signa...
Код: 845
ADT103 Set of Adapters and Fittings
The Additel ADT103 is a versatile adapter kit designed for precision and ease of use in pressure calibration tasks. It includes hand-tight quick connectors compatible with various male and female thread types such as NPT, BSP, and metric co...
Код: ADT103
PEGASUS-T
PEGASUS-T
New Solution…to Calibrate Short Sensors at High Temperatures The Pegasus range offers extreme high temperature calibration in an easy to use portable package – ideal for the calibration of high temperature thermocouples. It has been designe...
Код: PEGASUS-T
UNIK5000 Configurable Pressure Sensor
UNIK5000 Configurable Pressure Sensor
Druck's UNIK5000 configurator allows you to design your own pressure sensor for your specific application. With more than 200 million configurable combinations, the UNIK5000 configurator guides you through all available options to help you ...
Код: UNIK5000
PV211 Pneumatic Pressure Calibration Pump
PV211 Pneumatic Pressure Calibration Pump
The Druck PV211 Pneumatic Hand Pump is a lightweight, high quality combined pressure and vacuum hand pump. It has been designed to provide maximum pneumatic pressures efficiently and effortlessly. The PV211 can be used as a portable Pres...
Код: PV211
Dew-Point Calibration System - Michell DCS
Dew-Point Calibration System - Michell DCS
The DCS system is a complete rack-mounted calibration station capable of producing a flow of air (or nitrogen) at a pre-specified range of dew-point temperatures from a minimum of -100°C (-148°F) to a maximum of +20°C (+68°F). Through custo...
Код: DCS
QuickCal Blackbody
QuickCal Blackbody
When the high accuracy of the Gemini R is not necessary this product offers a cost effective solution for the calibration and testing of infrared thermometers. The QuickCal Blackbody is ideal for rapid and portable checking of infrared ther...
4.8182/5 11text_less_review
Код: QuickCal Blackbody
Small Hot Plate Model 983
Small Hot Plate Model 983
The Isotech Small Hotplate is a lightweight portable calibration system purpose designed for surface mounted sensors. The flat surface plate is made from precision-machined aluminum. The sensor to be tested is simply placed on the surface, ...
5.0000/5 1text_less_review
Код: 983
1000A PORTABLE ultra portable calibrator
1000A PORTABLE ultra portable calibrator
The 1000 series has transformed the world of calibration - its innovative design utilises the latest in cutting edge digital and analogue electronics, combined with the latest manufacturing techniques to create the world's first ultra-porta...
Код: 1000A
ADT917 Pneumatic Pressure Test Pump
ADT917 Pneumatic Pressure Test Pump
The ADT917 Pneumatic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 1,000psi (70bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution u...
Код: ADT917
AII GPR-1000 Portable PPM Oxygen Analyzer
Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in the...
Код: GPR-1000
Parallel Tube Liquid Bath Libra Model 785M
Parallel Tube Liquid Bath Libra Model 785M
Isotech calibration baths employ sophisticated designs to ensure calibration to the smallest of uncertainties. In 1986 Isotech purchased the interests of H N Irving & Sons Temperature division which had specialised in providing high quality...
Код: 785M
Rotronic PCMini52 - Digital RH Mini Probe with Temperature output
The micro processor control and multi-point calibration gives the PCMini52 RH probe excellent performance in terms of accuracy and linearity. The mini probe has two linear analog outputs for temperature and relative humidity...
Код: PCMini52
Blackbody ITS-90 Fixed Points
Blackbody ITS-90 Fixed Points
Primary Standard cells fit into the Medusa and Oberon, covering from Indium to Copper Points. These cylindrical cells are 42mm diameter and have a cavity 9mm diameter x 87mm deep. The Medium Temperature “Hockey Puck” cells are 64mm diameter...
Код:
Water Triple Point Maintenance Bath
This dedicated apparatus has more than 35 years of proven use and is widely used by the worlds’ leading NMIs. In a recent International study cells from 21 of the world’s leading laboratories were inter-compared; the study used two Isotech ...
Код: Water Triple
Blackbody Source Model 989
Blackbody Source Model 989
Isotech first introduced the Model 988 to assist in relation to the SARS outbreak during the early 2000s. Used to increase the accuracy of thermal imagers being used to measure human skin temperature in temperature screening of applications...
5.0000/5 2text_more_review
Код: 989
Спасибо!