Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

PEGASUS-T

- 150°C to 1100°C

- The Pegasus range offers extreme high temperature calibration in an easy to use portable package - ideal for the calibration of high temperature thermocouples. It has been designed for fast heating and finds applications in the glass, electrical power, automotive and material processing industries.

- Immersion Depth

- Calibrate Short Sensors

- Dynamic Heating Zone

Brief specifications


More details

New Solution…to Calibrate Short Sensors at High Temperatures The Pegasus range offers extreme high temperature calibration in an easy to use portable package – ideal for the calibration of high temperature thermocouples. It has been designed for fast heating and finds applications in the glass, electrical power, automotive and material processing industries. The Pegasus-T is the latest member of the Pegasus family developed for sensors that are simply too short to be calibrated in the Pegasus 4853 or other conventional calibration furnaces. The advanced control system allows the user to select optimal performance for sensors immersed at 25mm, 35mm or 50mm with three independent control loops. It also has built in over-temperature protection to protect the heater wire from over temperature thus increasing life expectancy. Immersion Depth Calibration engineers understand that to get the best accuracy temperature sensors should be immersed deeply into a calibration bath or furnace and compared to a reference thermometer. Calibrate Short Sensors But how to calibrate very short sensors such as those used in the automotive industry? These sensors are too short to go into conventional furnaces. The Isotech Pegasus Model 4853 has an immersion depth of 130mm which will suit many sensors but what if the sensor is very short, 25mm to 50mm? Large furnaces are unsuitable and calibrating these types of device provides a significant measurement challenge. Dynamic Heating Zone The new Pegasus-T has been developed for this very challenge and features a dynamic heating zone for short immersion probes providing a calibration source for sensors that are too short for other furnaces. It is being trialled and adopted at a number of customer sites in Europe and Asia and is now released for general sale. Pegasus-T allows you to choose an internal control sensor at the same depth the sensors under test, selecting from three internal noble metal control sensors or using an external control sensor placed at the same depth as the sensor under test. 1: Dynamic Heating Zone Choose one of three internal thermocouples to optimize performance for different length sensors. 2: Control From External Sensor Switch from the internal control sensor to an external Type R thermocouple that can be placed alongside the test sensor. 3: Independent Reference Channel Type R thermocouple input, can be used for external control or with a reference probe for an independent temperature measuring loop, option for UKAS calibration. Cautionary Note The operating life of the heater will vary with both the maximum operating temperature and the duty cycle. Units being used 24/7 at high temperatures may require a maintenance schedule for heater replacement Accuracy With short immersion probes there can be large errors as the sensor cannot be immersed deeply enough to allow it to reach the same temperature as the calibration block and there is a temperature gradient at the edge of the block. Tests show that the Pegasus-T is more useful than alternatives but there will always be a need to experiment and evaluate to determine the uncertainty for the conditions of use. It can be helpful to use a reference sensor of the same type as the units under test. Special Inserts We can design and manufacture inserts to suit your sensors… Calibration Blocks The Pegasus-T is supplied without an insert as most applications will require drilling to suit your requirement. Our CAD Designers can produce designs for your approval before manufacture in our workshop. Alternatively, we can provide blank inserts for you to manufacture or a pre-drilled insert with 6 x 5mm pockets, 100mm Deep. Advanced Features Fully featured high resolution display with advanced control features including multi loop control with autotune, adjustable temperature alarms with control from internal or external thermocouples Temperature Programmer Create, Edit and Store automatic programs for temperature stepping Reference Channel Input Can be used for external control or as a reference input. A Type R Thermocouple, Model 935-14-91 is included with each Pegasus-T Ethernet Interface Free Software, I-Cal Easy Log – web download Offset Elimination Connect the external reference probe and the calibrator can trim the block temperature to remove offsets USB Port Export logged data to a USB Key, controller data is continuously logged


ВимірюванняГенерація (Імітація)


PEGASUS-T

- 150°C to 1100°C

- The Pegasus range offers extreme high temperature calibration in an easy to use portable package - ideal for the calibration of high temperature thermocouples. It has been designed for fast heating and finds applications in the glass, electrical power, automotive and material processing industries.

- Immersion Depth

- Calibrate Short Sensors

- Dynamic Heating Zone

Featured Products

IO620-HOSE-H1 High pressure hydraulic hose
A high pressure hydraulic hose rated to 1,000 bar (15,000 psi) and terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. The hose is self sealing to avoid leakage...
Код: IO620-HOSE-H1
Dew-Point Calibration System - Michell DCS
Dew-Point Calibration System - Michell DCS
The DCS system is a complete rack-mounted calibration station capable of producing a flow of air (or nitrogen) at a pre-specified range of dew-point temperatures from a minimum of -100°C (-148°F) to a maximum of +20°C (+68°F). Through custo...
Код: DCS
MODEL 9200&9210DC MULTI-VALUE RESISTANCE STANDARDS & CURRENT SHUNTS
MODEL 9200&9210DC MULTI-VALUE RESISTANCE STANDARDS & CURRENT SHUNTS
THE 9200 AND 9210 PROVIDE DUAL CAPABILITIES AS A VERSATILE HIGH POWER MULTIPLE VALUE RESISTANCE STANDARD OR AS A PRECISION DC CURRENT SHUNT PRODUCT FEATURES Accuracy ± 0.01% (100 ppm) Resistance Values from 0.01 to 10,000 Ω (Model 9200) Res...
Код: MODEL
3000CS precision curent shunts precision references and standards
The 3000CS provides a precision set of current shunts for current ranges from 10mA through to 10A to provide additional ranges for multimeters that either lack sufficient accuracy at required currents, or lack the required current ranges en...
4.5000/5 14text_more_review
Код: 3000CS
3000ZR precision zener reference precision references & standards
3000ZR precision zener reference precision references & standards
The 3000ZR is an integrated 1.018V and 10V reference standard using multiple independent zeners. Backup power is provided via an internal rechargeable battery for transportation for calibration and use in your laboratory. The 3000ZR is fitt...
Код: 3000ZR
Additel 850 Laboratory Thermocouple Calibration Furnaces
Additel 850 Laboratory Thermocouple Calibration Furnaces
Thermocouple calibration work can be challenging. Here at Additel, we understand the difficulties of this type of work. Traditional furnace designs require several individual devices to meet industry standards for various calibration applic...
Код: ADT850-1200
HPPP480 Calibration system for gas meters with natural gas
HPPP480 Calibration system for gas meters with natural gas The calibration system serves as a standard for the calibration of gas meters of natural gas. The supply of natural gas occurs directly from a pipeline. The gas used for calibrat...
Код: HPPP480
Meteorology RH and T Probes - Rotronic MP100A/MP400A
The MP100A is a combined humidity and temperature probe designed primarily for meteorological and general outdoor applications. Operation from DC voltage and low power consumption make the MP101A particularly suitable for operation at remot...
Код: MP100A/MP400A
Local Evaluation Unit OPS
Local Evaluation Unit OPS
The Local Evaluation Unit OPS is a local microcomputer designed for comparison of reference impulses coming from the standard meter with optical impulses or reflexes from the black mark on the disk of the meter. Value of the measured error ...
Код: Unit OPS
Drago 4934
Drago 4934
Need advice on which model? Dry Block Selection Guide The Hyperion and Drago have large calibration volumes, 65mm x 160mm deep, which makes them ideal to use as portable liquid baths. Stirred liquid baths are suitable for temperature sensor...
Код: 4934
RH and Temperature Probe Calibrator - Rotronic HygroGen 2
RH and Temperature Probe Calibrator - Rotronic HygroGen 2
The HygroGen2 is a generator of controlled relative humidity and temperature environments, primarily for use in calibrating humidity instrumentation, but is also well suited to the calibration of temperature instrumentation, particularly ...
Код: HG2
6623A Series of High Current Range Extenders
6623A Series of High Current Range Extenders
Guildline’s 6623A Series of High Current Range Extenders / Sources is based on patented technology and provides the best in performance and modularity. The 6623A Series consists of a family of range extenders, with available current outputs...
Код: 6623A
Additel 760 Automatic Handheld Pressure Calibrators
Additel 760 Automatic Handheld Pressure Calibrators
A portable automated pressure calibrator in the palm of your hand—this could be our most exciting product yet! The Additel 760 series Automatic Handheld Pressure Calibrator takes portable pressure calibration to new levels. Weighing less th...
Код: ADT760
ACal (9530) Calibration Software
ACal (9530) Calibration Software
Additel ACal (9530) is a powerful software package designed for varying degrees of automation of calibrations and management of your laboratory. ACal combines pressure and temperature instrument calibration automation features with laborato...
Код: Acal
ADT260Ex Handheld Multichannel Reference Recorder
ADT260Ex Handheld Multichannel Reference Recorder
Additel's 260Ex is an intrinsically safe handheld multichannel reference recorder with 8 different channel configurations. Armed with Additel’s most versatile and capable handheld, technicians are now able to measure and collect data for pr...
Код: ADT260Ex
6535 RESISTANCE MEASUREMENT SYSTEM
6535 RESISTANCE MEASUREMENT SYSTEM
THE 6535 RESISTANCE MEASUREMENT SYSTEM IS THE MOST TECHNOLOGICALLY ADVANCED, HIGHLY MODULAR AND EASIEST TO USE HIGH RESISTANCE SYSTEM AVAILABLE ON THE MARKET TODAY PRODUCT FEATURES Two Modes of Operation, Bridge Mode and Direct Measurement ...
Код: 6535
Binary Gas Analyzer for Hydrogen Monitoring - Michell XTC601
Binary Gas Analyzer for Hydrogen Monitoring - Michell XTC601
A robust, linear and stable thermal conductivity analyzer for measurement of binary gas mixes such as air in hydrogen, nitrogen, argon, helium or carbon-dioxide. The sensor is housed in a rugged casing, making it suitable for a wide range o...
Код: XTC601
Ice mantle maker for water triple point cells
Ice mantle maker for water triple point cells
Are you fed up with cold wet hands, and hours of frustration when you produce an ice mantle in your Triple Point Cell? Change your life and try the Isotech Ice Mantle Maker. It works by using a specially designed anti-gravity heat pipe. The...
Код: Ice mantle
Gallium Fixed Point Cell
Gallium Fixed Point Cell
Second only to the Water Triple Point and in many ways, because of its ease of use and purity, superior to it, is the Gallium Melt Point. At 29.7646°C this is a very convenient temperature. Total Confidence Confidence is a major requirement...
Код: Gallium
700HPPK Pneumatic Test Pump
700HPPK Pneumatic Test Pump
The Fluke Calibration 700HPPK Pneumatic Test Pump Kit generates and adjusts pneumatic pressures up to 21 MPa (3000 psi), without requiring a nitrogen bottle or other external pressure supply. It supplies pressure to devices under test (DUTs...
Код: 700HPPK
Спасибо!