Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

ADT104-HP Set of Adapters and Fittings

- 17 high pressure adapters

- Working pressure: up to 4200 bar

- Included: sealing rings

- Material: stainless steel

- Carrying case

Brief specifications

17 high-pressure adapters for common threads

1/4 HP male BSP, NPT, metric adapters

Wetted material: stainless steel

Working pressure: from 1000 to 4200 bar

Included: sealing rings

Set in a plastic case for storage and transportation

More details

The Additel ADT104-HP is a high-pressure adapter kit designed to support various calibration and pressure testing needs. It includes a set of 17 adapters with a 1/4HP male (Autoclave M-250-C) connection, compatible with Additel models such as the ADT959A, and ADT960 pumps. The kit offers maximum pressures ranging from 15,000 psi to 60,000 psi, depending on the adapter configuration. It provides versatile connectivity to BSP, NPT, and metric fittings, making it ideal for a wide range of industrial applications.

Each adapter is built for durability and high precision, ensuring reliable performance in demanding environments. The kit comes in a specially designed carry case for easy transportation and organization, which is particularly useful for field service applications.


ВимірюванняГенерація (Імітація)


ADT104-HP Set of Adapters and Fittings

- 17 high pressure adapters

- Working pressure: up to 4200 bar

- Included: sealing rings

- Material: stainless steel

- Carrying case

Featured Products

IO620-BSP  A set of test point adaptors
IO620-BSP  A set of test point adaptors
A set of test point adaptors to connect the tool less quick fit PV62XG, MC620G and the extension hoses to the device under test...
Код: IO620-BSP
precis.io
precis.io
Application works as Control Software for products of Applied Precision. It can show measured values, control meter error measurement and generation of signals (in PTE device)...
Код: precis
Fast-Cal High
Fast-Cal High
Fast-Cal – the product range you designed During early 2004 20 experienced engineers from many parts of the world were asked to produce their ideal specification for industrial calibration. Their top ten requirements, in order of priority, ...
5.0000/5 1text_less_review
Код: High
Hyperion 4936
Hyperion 4936
Need advice on which model? Dry Block Selection Guide The Hyperion and Drago (30°C to 250°C) have large calibration volumes, 65mm x 160mm deep, which makes them ideal to use as portable liquid baths for high accuracy calibration of awkwardl...
2.0000/5 1text_less_review
Код: 4936
PressCal Software for DWT Fluke
PressCal Software PressCal is a menu driven software program for pressure calculation and certificate generation using a deadweight tester as the pressure source. This software has been developed as a flexible working tool to make calibrat...
Код: PressCal Software
IO620-HOSE-P2 Pneumatic hose
IO620-HOSE-P2 Pneumatic hose
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Safe area use 2 m/3.28 ft pneumatic hose. Maximum pressure 400 bar/5800 psi...
Код: IO620-HOSE-P2
AII GPR-1200 Portable PPM Oxygen Analyzer
Analytical Industries’ high-accuracy portable oxygen analyzers are for applications which must be controlled at several defined measurement points. The GPR-3500 model has a compact, rugged enclosure and includes stainless steel wetted parts...
Код: GPR-1200
3000ZR precision zener reference precision references & standards
3000ZR precision zener reference precision references & standards
The 3000ZR is an integrated 1.018V and 10V reference standard using multiple independent zeners. Backup power is provided via an internal rechargeable battery for transportation for calibration and use in your laboratory. The 3000ZR is fitt...
Код: 3000ZR
P3000 Pneumatic Deadweight Testers
P3000 Pneumatic Deadweight Testers
The P3000 Series is the culmination of over 50 years of experience in the production and design of high performance pressure standards. With features designed to improve accuracy and performance, increase reliability and simplify operation ...
Код: P3000
3000RS precision resistance standard precision references and standards
3000RS precision resistance standard precision references and standards
The 3000RS is a modern precision resistance standard offering annual stabilities of better than 5ppm without the requirement for an oil bath, with temperature co-efficients as low as 0.1ppm/°C Using ultra-high precision, 4 wire hermetically...
Код: 3000RS
ADT601Ex Digital Pressure Gauges
ADT601Ex Digital Pressure Gauges
The ADT601Ex intrinsically safe digital pressure gauge is designed to improve upon traditional dial pressure gauges by providing a reliable and accurate digital solution for a minimal investment. The included Bluetooth technology allows use...
Код: ADT601Ex
Adapters
Adapters
A complete list of possible adapters is indicated in the specifications...
Код: Адаптер
Dew-Point Transmitter - Michell Easidew 34
The Easidew 34 is a dew-point transmitter with a 3/4” process connection. Designed for use in industrial conditions, it has a wide measurement range from -110 to + 20 °C dew point. Based on Ceramic Metal-Oxide Moisture Sensor the Easidew 3...
Код: Easidew 34
Stirred Ice Bath Model 813
Stirred Ice Bath Model 813
The most used temperature for calibration is 0°C. The normal way of creating 0°C is via a mixture of ice and water in a Dewar Flask. However, this can give errors of up to 4°C because water is densest at 4°C and so as the ice melts the temp...
Код: 813
Quick Cal High
Quick Cal High
Isotech’s Quick Cal range of testers are ideally suited to the less exacting applications where our larger, better specified baths are unnecessary. The Low Temperature Quick Cal covers the temperature range of -12°C to +140°C, making it ide...
Код: Quick Cal High
Precision Electronically Compensated Voltage Transformer CMR-U
Other Features The Common Mode Rejecter (CMR) is an electronically compensated uncoupling unit for elimination of interaction of simultaneously tested electricity meters having interconnected current and voltage circuits (closed I-P links)....
Код: CMR-U
ADT104-HP Set of Adapters and Fittings
ADT104-HP Set of Adapters and Fittings
The Additel ADT104-HP is a high-pressure adapter kit designed to support various calibration and pressure testing needs. It includes a set of 17 adapters with a 1/4HP male (Autoclave M-250-C) connection, compatible with Additel models such ...
Код: ADT104
Orion Model 796H
Orion Model 796H
The Isotech Hydra range of calibration baths have proved very successful since their introduction in 2003. The Orion range has been introduced to fit alongside the Hydra models. The Orion calibration baths offer deeper calibration volumes t...
Код: 796H
Miniature Fixed Resistor Model 836
Isotech produces a miniature resistor with ultra-low temperature coefficient and ultra-high stability. This is achieved because the resistors are oil filled and hermetically sealed. The function of hermetic sealing is to eliminate the ingre...
Код: 836
Self-Contained Hygrometer- Michell Drycheck
Self-Contained Hygrometer- Michell Drycheck
A simple and efficient, self-contained dew-point hygrometer, with filtration and flow control, for measurement of dew point or moisture content at point of use. It uses the Easidew On-Line to measure dew point in the range –100 to + 20 °C d...
Код: Drycheck