Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

2468A Pitot/Static Primary Standard

- Pressure range to 400 inHg

- Accuracy: Up to ±0.5 feet, 0.003 knots

- Working media: clean nitrogen/air

- Intended for calibration Ps, Pt & Qc 

- Automatic rotation of loads

- Mounted level and adjustable feet

Brief specifications

Pressure range from 0.4 to 103 inHg and from 3.4 to 400 inHg

Accuracy: Up to ±0.5 feet, 0.003 knots

High long-term stability up to 3 ppm per year

Working media: clean/dry nitrogen or air

Intended for absolute and gauge calibration for Ps, Pt & Qc ranges

Automatic rotation of loads

Mounted spirit level and adjustable feet

Gauge, absolute, vacuum (negative gauge) measurement modes

Non-magnetic materials to provide long-term stability

Monitoring of temperature, humidity, pressure and air density (option)

More details

The Model 2468 Pitot Static Primary Standard is specifically designed for calibrating today’s high performance flight line and Air Data Test Systems. With the new autofloat controller, operator intervention is reduced to simply applying the mass load indicated by WinPrompt® software. WinPrompt applies all required correction factors, real time, to insure attainment of the highest level of performance available in a gas piston gauge which is required to calibrate today’s RVSM compliant test sets. The Model 2468 is based on the popular Model 2465 Gas Piston Gauge which has a long history of serving national standards laboratories, commercial industry and government organizations as a primary pressure standard for over 50 years. Time-proven materials, hand craftsmanship, and a lineage of intercomparisons to national standards laboratories at the highest levels are coupled with new automated technology to make the Model 2468 Pitot Static Primary Standard the world’s choice for calibrating Air Data Test Systems.

Piston/cylinder assemblies

For calibrating most Pitot Static Test Sets, only the standard piston/cylinder supplied is required. The standard piston/cylinder generates pressures from 1.4 to 103 inHg in autofloat mode and from 0.4 to 103 inHg using a manual pressure adjuster. This provides an effective altitude range from -610 to 19,812 meters (-2,000 to 65,000 feet) feet in autofloat mode -610 to 27,432 meters (-2,000 to 90,000 feet) using a manual adjuster) and airspeeds over 1,000 knots. An optional piston/cylinder is available for generating pressures from 3.4 to 400 inHg allowing calibration of other pressure related devices, such as pressure transducers.

Both the standard and optional piston/ cylinder assemblies are manufactured from proven materials that have evidenced superior strength, durability, low distortion, low thermal coefficients and virtually undetectable hysteresis over the last several decades, and have an unparalleled record of long-term stability. Each piston/cylinder installs quickly into the pressure column without the need for special tools. Piston/cylinder assembly change-out can be completed in less than one minute.

Mass set

The Model 2468 is provided with a single mass set that is used with either the standard or optional piston/cylinder. Each mass is engraved with a unique sequence number and a common serial number. A storage case is supplied which allows storage of the mass set and one or both piston/cylinders. Each mass is machined to a nominal value and is made from nonmagnetic materials to provide long-term stability and eliminate sensitivity to magnetic fields. For ease of use, the entire mass set totals just 12 kilograms (26.40 pounds), with a maximum platter mass of 1 kilogram (2.2 pounds). A laboratory grade trim mass set is included to allow any pressure increment within the range and resolution of the piston/cylinder assembly.

Instrument base

The instrument base is designed with functionality, economy and space conservation in mind. All electronic components are housed away from the instrument base to eliminate errors caused by thermal effects and magnetic fields. The thermally isolated motor drive is connected to the cylinder—eliminating pressure fluctuations and maximizing productivity. A durable, acrylic bell jar is provided to allow absolute mode operation when calibrating altitude and other absolute reference devices. A KF16 fitting is provided to simplify installation and allow low reference pressures

Vacuum pumps

In order to operate over the entire altitude and airspeed range, two vacuum pumps are required. One pump is connected to the reference port of the Model 2468 using a KF16 connection. This allows the area inside the bell jar to be evacuated which is required for altitude calibrations (absolute mode). A second vacuum pump is connected to the autofloat controller which allows automatic control of pressures down to 1.4 inHg absolute. In order to generate positive pressures, a regulated gas supply (clean dry air, or nitrogen) must be supplied to the autofloat controller. Fluke Calibration can supply vacuum pumps which are rated to the appropriate vacuum capacity and include an auto-vent valve and backstream filter for contamination prevention along with a muffler for quiet operation.

Connecting lines and fittings

Fluke Calibration can provide an optional lines and fittings kit which includes all interconnecting tubing for pressure and vacuum supplies along with all required cables and adapters.

Manual configuration

Fluke Calibration also offers a manually operated pressure control system for setting the pressure and float position. This configuration can also be used with WinPrompt software and the Model 2456 Deadweight Gauge Monitor. The Model 2456 continuously monitors piston temperature, float position, and sink rate, and optionally air density and reference vacuum. WinPrompt calculates mass-to-pressure and pressure-to-mass values, and when used with the Model 2456, automatically reads and displays real-time piston gauge parameters. A separate brochure is available that covers the Model 2456 Deadweight Gauge Monitor.


ВимірюванняГенерація (Імітація)


2468A Pitot/Static Primary Standard

- Pressure range to 400 inHg

- Accuracy: Up to ±0.5 feet, 0.003 knots

- Working media: clean nitrogen/air

- Intended for calibration Ps, Pt & Qc 

- Automatic rotation of loads

- Mounted level and adjustable feet

Featured Products

8158 Advanced Digitising Multimeter advanced multimeter
The NEW 8158 Advanced Digitising Multimeter from Transmille has been designed as a modern replacement for aging multimeters without compromise. Capable of measurements at a rate of over 100,000 Samples per second, the 8158 8.5 Digit Multime...
4.2000/5 5text_lot_review
Код: 8158
Compact Sampling System - Michell ES20
Compact Sampling System - Michell ES20
The ES20 Compact Sampling System is designed to reliably and accurately measure dew point or moisture content in a wide variety of industrial gas applications up to 20 barg. This sampling system is an economical and high-quality solution wi...
Код: ES20
8270A High-Pressure Controller
8270A High-Pressure Controller
The 8270A measures and controls pressures from vacuum to 44 MPa (6400 psi). It can be configured with ranges as low as 100 kPa (15 psi). Fluke Calibration’s unique control technology enables you to use these calibrators at low or high pres...
Код: 8270A
ACal (9530) Calibration Software
ACal (9530) Calibration Software
Additel ACal (9530) is a powerful software package designed for varying degrees of automation of calibrations and management of your laboratory. ACal combines pressure and temperature instrument calibration automation features with laborato...
Код: Acal
DPI620 Genii Advanced Modular Calibrator
DPI620 Genii Advanced Modular Calibrator
Multifunction Calibrators Measure pressure, temperature, and electrical signals with greater accuracy with Druck’s portable multifunction calibration tools. Druck multifunction calibrators provide an all-in-one solution for your pressure me...
Код: DPI620G
AII GPR-7500 PPM H2S Analyzer
AII GPR-7500 PPM H2S Analyzer
The GPR-7500 analyzer utilizes the low-power electro-chemical sensor technology to provide a cost-effective and easy to maintain online-installation hydrogen sulfide measurement in a small package. The GPR-7100 is a portable H2S analyzer ve...
Код: GPR-7500
Medusa 510
Medusa 510
Isotech have a wide range of Dry Blocks to suit probes requiring a large immersion depth. These products feature large and deep calibration volumes. As such they are less portable than the earlier Dry Blocks, but have higher capacities and ...
Код: 510
DPI800/802 Pressure Indicator /Loop Calibrator
DPI800/802 Pressure Indicator /Loop Calibrator
DPI 800/802 Druck Pressure Indicator/Loop Calibrator The DPI 800 Series is a complete range of advanced, robust and simple to use hand-held instruments. Highly cost effective, these tools are ideal for test/calibration of many popular proce...
Код: DPI800/802
INSERTION PROBES HYGROCLIP2 HC2-P05/HP28
The insertion probe is suitable for measurement in dust-free bulk materials, bricks, concrete, etc (10 mm insertion probe: measurements in dusty bulk materials such as flour, sugar, etc.). It measures humidity and temperature and calculates...
Код: HC2-P05/HP28
ADT783 Pressure Controller
ADT783 Pressure Controller
These modular pressure controllers combine cutting-edge control/measurement technology, modular design, and user-friendly features. The Additel 783 controller series is optimized for high speed to pressure without compromising accuracy and ...
Код: ADT783
Handheld Water Activity Meter - Rotronic HygroPalm HP23-AW
Handheld Water Activity Meter - Rotronic HygroPalm HP23-AW
In many situations it can be very useful to measure water activity at goods-in, production or storage rooms, e.g. inspection of bulk materials to ensure they meet specifications...
Код: HP23-AW
GPR-28
GPR-28
The GPR-35, GPR-2500 SN and GPR-2800 IS/AIS-S are reliable oxygen deficiency monitors for measuring the oxygen concentration in rooms where there is potential for gas leaks to prevent oxygen depletion or asphyxiation and ensure safety of pe...
Код: GPR-28
AII GPR-1000 Portable PPM Oxygen Analyzer
Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in the...
Код: GPR-1000
Gas Flow Model 984
The higher temperature Isotech Blackbody Fixed Point Cells consist of high purity metals within a graphite body. Graphite reacts with air to form Carbon Dioxide. The rate of the reaction is temperature dependant. The effect is small at low ...
2.0000/5 1text_less_review
Код: 984
Weather Shields - Rotronic AC Series
Weather Shields - Rotronic AC Series
Naturally ventilated shields are used where the natural ventilation (wind) suffices, e.g. measurement stations in the mountains...
Код: AC
microK Channel Expander
microK Channel Expander
The microsKanner can be used with any member of the microK family to add further channels, up to a maximum of 90 expansion channels. Easy to Use: The use of plug-and-play technology means that the extra channels appear automatically on your...
Код: microK
precis.io
precis.io
Application works as Control Software for products of Applied Precision. It can show measured values, control meter error measurement and generation of signals (in PTE device)...
Код: precis
6625A is the only true modular Resistance and Current Measurement System
6625A is the only true modular Resistance and Current Measurement System
Guildline Instruments 6625A is the only true modular Resistance and Current Measurement System providing users with unique industry leading features and capabilities. PRODUCT FEATURES Complete Turn-Key System – Fully Integrated, Wired, Test...
Код: 6625A
Process Moisture Analyzer - Michell Promet I.S
Process Moisture Analyzer - Michell Promet I.S
Promet I.S. Process Moisture Analyzers are heavy duty, industrial hygrometer systems for measurement of high pressure, process gases and vaporized liquids on natural gas platforms and terminals, petrochemical plants and industrial gas manuf...
Код: Promet I.S
Rotronic CO2 Display for Indoor Air Quality Monitoring (CL11, CP11)
Rotronic CO2 Display for Indoor Air Quality Monitoring (CL11, CP11)
Indoor Air Quality (IAQ) measurements in offices, conference rooms, schools, etc. Application range: 0...50 °C / 0...95 %rh, non-condensing CO2 Measurement principle: Infrared (NDIR) with automatic calibration (ABC) CO2 Display Wal...
Код: CL11_ CP11
Спасибо!