- Automate your Gallium point Model 17402B Gallium Apparatus is not an adaptation from general purpose equipment, but is designed specifically to realise and maintain the Gallium Cell on the melt plateau, for calibration of thermometers on the International Temperature Scale of 1990.

- Simple, automatic and safe operation

- Reproducibility day-to-day of ±0.000025°C

- 20 years of world-wide deliveries without breakage

- 99.999999% purity

Brief specifications


More details

Model 17402B Gallium Apparatus is not an adaptation from general purpose equipment, but is designed specifically to realize and maintain the Gallium Cell on the melt plateau, for calibration of thermometers on the International Temperature Scale of 1990. The apparatus will permit the gallium to melt coaxially over 12 to 16 hours. It is uniquely designed to also freeze the cell from the bottom up, which eliminates the danger of damage due to the expansion of gallium during freezing. Model 17401 Gallium Cell may be used in a well controlled bath without the need for the thermal environment provided by Model 17402B Gallium Apparatus. However, because of the advantages of automatic operation, convenience and cell protection, Isotech recommend the use of the Model 17402B environment in most cases. No external connections other than power are required. A completely automatic electronic control system provides a precise means for realization and maintenance of the plateau. The Apparatus can be turned on by a timer an hour before the laboratory day begins, the plateau utilized throughout the working day and the system recycled overnight. A thermal sink is provided which forces the gallium to refreeze upwards from the bottom (gallium expands when it freezes, requiring a specific freeze orientation to avoid rupturing the cell). Confidence is a major requirement in a standard. The Isothermal Gallium Cell and Apparatus have a long (20 year) history and have been successfully used in most National and Primary Laboratories world-wide. This is one of the main reasons for choosing the Isothermal Cell and Apparatus. The Cell and Apparatus are manufactured to the strict requirements of BS 5750 and ISO 9000. Each finished unit becomes part of the Isotech UKAS working Calibration Laboratory for two weeks or more, during which use the control circuits are set and checked for optimum performance. It is released only when Isotech are entirely satisfied with its performance.


ВимірюванняГенерація (Імітація)


Документация

Gallium Fixed Point Apparatus

- Automate your Gallium point Model 17402B Gallium Apparatus is not an adaptation from general purpose equipment, but is designed specifically to realise and maintain the Gallium Cell on the melt plateau, for calibration of thermometers on the International Temperature Scale of 1990.

- Simple, automatic and safe operation

- Reproducibility day-to-day of ±0.000025°C

- 20 years of world-wide deliveries without breakage

- 99.999999% purity

Featured Products

4857 Gemini 550
4857 Gemini 550
Need advice on which model? Dry Block Selection Guide The Gemini range of Dry Blocks have high capacity allowing a large number of probes to be calibrated together. They are also suitable to accept large diameter probes with the block volum...
Код: 4858
Isobox Model 842
Isobox Model 842
The function of this reference unit differs from other cased systems in that the temperature of the metal block in which the thermocouple and copper leads are inserted, actually varies with ambient temperature. A separate output signal is p...
Код: 843
IOHOSE-NP2 Pneumatic hose
IOHOSE-NP2 Pneumatic hose
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Safe area use 2 m/3.28 ft pneumatic hose. Maximum pressure 20 bar/300 psi...
Код: IOHOSE-NP2
P5543 Angle Adapter
To calibrate gauges with the pressure connection on the rear (for example, panel mount gauges) in their correct operating position, an angle adaptor should be used. The angle adapter uses the standard gauge adapters and positions the gauges...
Код: P5543
Cost Effective Humidity Validator - Michell S904
Cost Effective Humidity Validator - Michell S904
The S904 is a stand-alone and transportable humidity calibrator which is easy to use and maintain. The calibration chamber features 5 interchangeable ports to accommodate virtually any brand, type or model of humidity sensor. This calibrato...
Код: S904
Isotech Model 96178 HTSPRT
Isotech Model 96178 HTSPRT
Isotech has produced over 200 high temperature thermometers which have been sold world-wide for use up to the silver point. As a consequence of our predelivery testing alone we have probably made more silver point calibrations than anyone e...
Код: 96178
IO620-HOSE-P1-IS Pneumatic hose in hazardous area use
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Hazardous area use 1 m/3.28 ft pneumatic hose. Maximum pressure 400 bar/5800 psi...
Код: IO620-HOSE-P1-IS
Automatic Humidity Probe Calibrator - Michell HG10
Automatic Humidity Probe Calibrator - Michell HG10
The Michell HG10 Humidity Calibration System is a computer-controlled automatic calibration system for humidity sensors. The HG10 is capable of repeatable generation of temperature and relative humidity set points over the range 1 to 95% RH...
Код: HG10
8270A High-Pressure Controller
8270A High-Pressure Controller
The 8270A measures and controls pressures from vacuum to 44 MPa (6400 psi). It can be configured with ranges as low as 100 kPa (15 psi). Fluke Calibration’s unique control technology enables you to use these calibrators at low or high pres...
Код: 8270A
7223CT-2S Series of Precision AC Current Transformers
7223CT-2S Series of Precision AC Current Transformers
Guildline Instruments NEW 7223CT-2S Series of Precision AC Current Transformers provides very accurate AC current measurements at high current and for high voltages. The 7223CT-2S is part of the 7223CT Series which are Commercially Availabl...
Код: 7223CT-2S
Dew-Point Hygrometer - Easidew Advanced Online
Dew-Point Hygrometer - Easidew Advanced Online
Код: Easidew Advanced Online
Gas Flow Model 984
The higher temperature Isotech Blackbody Fixed Point Cells consist of high purity metals within a graphite body. Graphite reacts with air to form Carbon Dioxide. The rate of the reaction is temperature dependant. The effect is small at low ...
2.0000/5 1text_less_review
Код: 984
PG9602/9607 Piston Gauge
PG9602/9607 Piston Gauge
The PG9607 is the next generation of absolute pressure piston gauge from Fluke Calibration. It supports the use of a 100 kg mass set to define gauge and absolute pressures from 11 to 500 kPa with a single piston-cylinder. The PG9602 is the ...
Код: PG9602/9607
Humidity Validator - Michell HygroCal100
Humidity Validator - Michell HygroCal100
The HygroCal100 provides a stable test chamber to quickly evaluate the performance of relative humidity sensors across a wide range of 5 to 95% relative humidity. Its intuitive 4” touch screen display and interface allows the probes under ...
Код: HygroCal100
AC/DC shunts precision references and standards
AC/DC shunts precision references and standards
Transmille offer a set of current shunts enabling measurement of current from 1mA through to 100A. Each shunt develops 0.7V at nominal full scale, enabling a wide range of multimeters to be used without loss of resolution due to changing ra...
Код: AC/DC
Differential Pressure Transmitter - Rotronic PF4/5
Differential Pressure Transmitter - Rotronic PF4/5
Measuring and Monitoring differential Pressure in Clean Rooms, Food and Pharma. Choice of two different sensor technologies (thermal measuring method and diaphragm sensor) The new differential pressure transmitters PF4 and PF5 with two dif...
Код: PF4/5
IO620-NPT A set of test point adaptors
IO620-NPT A set of test point adaptors
A set of test point adaptors to connect the tool less quick fit PV62XG, MC620G and the extension hoses to the device under test...
Код: IO620-NPT
1000A PORTABLE ultra portable calibrator
1000A PORTABLE ultra portable calibrator
The 1000 series has transformed the world of calibration - its innovative design utilises the latest in cutting edge digital and analogue electronics, combined with the latest manufacturing techniques to create the world's first ultra-porta...
Код: 1000A
ADT912-X-KIT Test kit for connection
A set for connecting measuring equipment with each other using silicone tubes (fittings, silicone tubes and adapters). X = connection type, eg N - 1/4 NPT male, N2 - 1/2 NPT male, B - 1/4 BSP male, B2 - 1/2 BSP male, M - M20X1.5 male...
Код: ADT912-X-KIT
Industrial Humidity Transmitters HVAC - Rotronic HygroFlex HF3 and HF4
Industrial Humidity Transmitters HVAC - Rotronic HygroFlex HF3 and HF4
The HygroFlex3 series is ideal for all applications where good accuracy measurement of humidity and temperature is of critical importance. The transmitters can be used in a wide range of industries...