Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

Drago 4934

- 30°C to 250°C

- The Drago and Hyperion (-25°C to 140°C) have large calibration volumes, 65mm x 160mm deep, which makes them ideal to use as portable liquid baths for high accuracy calibration of awkwardly shaped sensors.

- Multi Function: Six Modes including Dry Block and Liquid Bath

- 65mm Volume: Ideal Liquid Bath

- Calibrate entire measurement loop - using a heat source rather than an electrical simulator, a test instrument and sensor can be calibrated as a system

Brief specifications


More details

Need advice on which model? Dry Block Selection Guide The Hyperion and Drago have large calibration volumes, 65mm x 160mm deep, which makes them ideal to use as portable liquid baths. Stirred liquid baths are suitable for temperature sensors of all types, sizes and shapes. Liquid Baths can provide smaller calibration uncertainties than dry blocks and when used with suitable reference thermometers, accuracies of up to 0.005°C can be achieved. These models are part of the award winning Isocal-6 family and with a reference probe can be used with different accessories for Dry Block, Infrared, Surface Calibration and even with ITS-90 Fixed Point Cells for uncertainties to 0.001°C. In Dry Block Mode, the large 65mm diameter block allows for the calibration of either larger probes or for calibrating many sensors simultaneously. As a Liquid bath the sensors can be placed directly into the stirred liquid thus avoiding the need for specially drilled blocks. If the liquid is directly in the block then the controller only model, or Basic (B) model, can be selected. However, instead of putting liquids directly in the block liquid containers can be used to facilitate rapid change of fluids. For greater accuracy, or when using a liquid container, Dry Block Insert, Blackbody Target or the Surface Sensor Kit a separate reference thermometer should be used to compensate for the varying offset between the controller and the accessory temperature. An ideal arrangement would be to include the handheld Isotech TTI-10 or the bench top Isotech milliK Precision Thermometer and Model 935-14-16 Semi Standard Platinum Resistance Thermometer. Alternatively the SITE or ADVANCED model can be selected; the SITE includes a temperature indicator for a reference probe. The ADVANCED also includes inputs for test thermometers, automatic temperature cycling, logging and additional sophisticated features. All models include I-Cal Easy LOG software and the ADVANCED models additionally include software to manage logged data and configure the unit, more details.


ВимірюванняГенерація (Імітація)


Drago 4934

- 30°C to 250°C

- The Drago and Hyperion (-25°C to 140°C) have large calibration volumes, 65mm x 160mm deep, which makes them ideal to use as portable liquid baths for high accuracy calibration of awkwardly shaped sensors.

- Multi Function: Six Modes including Dry Block and Liquid Bath

- 65mm Volume: Ideal Liquid Bath

- Calibrate entire measurement loop - using a heat source rather than an electrical simulator, a test instrument and sensor can be calibrated as a system

Featured Products

3210T Thermometry Auto-Switch with Pre-Heat
3210T Thermometry Auto-Switch with Pre-Heat
Guildline's NEW 3210 Series of Thermometry Auto-Switch with Pre-Heat automates temperature measurements including fixed points and thermometer calibrations. Up to eight PRTs or other temperature devices can be connected with individually pr...
Код: 3210T
IO620-COMP Comparator adaptor
IO620-COMP Comparator adaptor
Comparator adaptor Allows the PV62XG pressure station to be used as a comparator. The adaptor connects to the stations pressure port and provides two outlet ports for making gauge comparisons. Compatible with the test point adaptors supplie...
Код: IO620-COMP
Cyclops Model 878
Cyclops Model 878
The Cyclops Model 878 is a spherical blackbody source. It consists of an inner black sphere that sits inside a spherical furnace and is suitable for use as a radiation source for infrared thermometers. The inner sphere has a nominal diamete...
4.0000/5 2text_more_review
Код: 879
Humidity Temperature Probes - Rotronic HC2-HK/C
HC2-HK25 / HC2-HK40 The handheld probe is especially suitable for mobile measurements of high temperatures. It measures humidity and temperature and calculates the dew/frost point. Applications Climatic and temperature chambers, dryers, ...
Код: HC2-HK/C
3130 Portable Pressure Calibrator
3130 Portable Pressure Calibrator
The 3130 Portable Pneumatic Pressure Calibrator is ideal for calibrating pressure transmitters, transducers, gauges and similar devices. The 3130 contains everything you need to generate, control and measure pressure, as well as read the ou...
Код: 3130
ADTS552F Air data test system
ADTS552F Air data test system
The ADTS552F air data test set is a portable two-channel flightline pitot static tester with large pitot static volume capability for use on a wide range of aircraft, from light aircraft to wide body passenger and freight aircraft. It provi...
Код: ADTS552F
3000ZR precision zener reference precision references & standards
3000ZR precision zener reference precision references & standards
The 3000ZR is an integrated 1.018V and 10V reference standard using multiple independent zeners. Backup power is provided via an internal rechargeable battery for transportation for calibration and use in your laboratory. The 3000ZR is fitt...
Код: 3000ZR
AII GPR-2900 Oxygen Analyzer With Remote Sensor
AII GPR-2900 Oxygen Analyzer With Remote Sensor
A panel mounted oxygen analyser with a remote sensor allows flexibility of installation. The GPR-1900 gas analyzer is suitable for trace oxygen measurements as low as 0-10 ppm; the GPR-2900 measures O2 up to 100%. The remote sensor block al...
Код: GPR-2900
Dew-Point Calibration System - Michell DCS
Dew-Point Calibration System - Michell DCS
The DCS system is a complete rack-mounted calibration station capable of producing a flow of air (or nitrogen) at a pre-specified range of dew-point temperatures from a minimum of -100°C (-148°F) to a maximum of +20°C (+68°F). Through custo...
Код: DCS
Stirred Ice Bath Model 813
Stirred Ice Bath Model 813
The most used temperature for calibration is 0°C. The normal way of creating 0°C is via a mixture of ice and water in a Dewar Flask. However, this can give errors of up to 4°C because water is densest at 4°C and so as the ice melts the temp...
Код: 813
Miniature Fixed Resistor Model 836
Isotech produces a miniature resistor with ultra-low temperature coefficient and ultra-high stability. This is achieved because the resistors are oil filled and hermetically sealed. The function of hermetic sealing is to eliminate the ingre...
Код: 836
RBC Resistance Bridge Calibrators
RBC Resistance Bridge Calibrators
Operating principles The problem: Temperature measurement is one of the most demanding applications of resistance measurement. It requires the measurement of resistance ratios to accuracies of 0.1ppm or better. While dc resistance standards...
5.0000/5 1text_less_review
Код: RBC
TRU Model 938
TRU Model 938
The TRU (Thermocouple Reference Unit) supplies a stable and accurate 0°C, or elevated reference temperature. It is a self-contained all solid-state unit using Peltier technology which provides maintenance free operation. The TRU features ra...
Код: 938
Flow generator
Flow generator Simulating breathing air flows for the calibration of flow sensors (air) The test bench is used to calibrate air flow sensors for lung function diagnostics and is designed for simulating the human breathing air. By usin...
Код: FG
Gallium Fixed Point Cell
Gallium Fixed Point Cell
Second only to the Water Triple Point and in many ways, because of its ease of use and purity, superior to it, is the Gallium Melt Point. At 29.7646°C this is a very convenient temperature. Total Confidence Confidence is a major requirement...
Код: Gallium
DххP Pneumatic Cylinder Hand Pump
DххP Pneumatic Cylinder Hand Pump
An economical solution for low-pressure applications, we offer three cylinder hand pump options with a modular design that makes field maintenance quick and easy. Our DP0V model provides reliable test pressure up to 125 psi (860 kPa), the D...
Код: DxxP
Jarrett-Isotech Water Triple Point Cells
Jarrett-Isotech Water Triple Point Cells
The Water Triple Point is the most important fixed point, the only point common to the ITS-90 and the Thermodynamic Temperature Scale. It is an essential reference point for every temperature laboratory. The Jarrett-Isotech cells are the be...
Код: Jarrett
ADT686 Digital Pressure Gauge
ADT686 Digital Pressure Gauge
Additel's ADT686 Advanced Digital Pressure Gauges will redefine the way you want to measure pressure! With wireless remote connectivity, microprocessor technology, state of-the-art silicon pressure sensors and optional onboard storage capac...
Код: ADT686
IO620-IDOS-USB IDOS to USB converter
IO620-IDOS-USB IDOS to USB converter
IDOS to USB converter Allows connection of an IDOS universal pressure module to the DPI620G. P/N IO620-USB-PC is also required to connect the converter to the DPI620G USB port. (not compatible with DPI620G-IS)...
Код: IO620-IDOS-USB
IO620-HOSE-P1-IS Pneumatic hose in hazardous area use
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Hazardous area use 1 m/3.28 ft pneumatic hose. Maximum pressure 400 bar/5800 psi...
Код: IO620-HOSE-P1-IS
Спасибо!