Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

Temperature Controlled Fixed Resistors

- Nominal Temperature Coefficient of Resistance: +0.02ppm/°C (with temperature control on) 18 to 25°C

- Model 456. By temperature controlling an otherwise very stable resistor a performance close to the very best available World-wide can be achieved at a surprisingly low price.

- Nominal Temperature Coefficient of Resistance: +0.02ppm/°C (with temperature control on) 18 to 25°C

- Power Rating: 0.5 Watt at +25°C

- Standard models: 10, 25, 100, 1000 and 10,000Ω

- Current Noise: <0.010µV (RMS) / Volt of Applied Voltage

- Thermal EMF: 0.1µV/°C Max; 0.05µV/°C Typical

- The most precise and stable resistors available

- Impervious to harmful environments - oil filled

Brief specifications


More details

By temperature controlling an otherwise very stable resistor a performance close to the very best available World-wide can be achieved at a surprisingly low price. The resistor itself is oil filled and hermetically sealed. The function of hermetic sealing is to eliminate the ingress of moisture and oxygen both of which play a role in the long term degradation of unsealed resistors. A further enhancement in both short and long term stability is achieved by oil filling. The oil also acts as a thermal conductor allowing the device to accept short periods of overload without degradation. With accuracies of ±0.005%, a wide resistance range and long term drift of less than 5ppm, these devices are virtually secondary standards that can be kept in a laboratory as references to calibrate other devices. The Resistor is held in a temperature controlled environment heated to 30°C ±0.1°C other temperatures are available to special order. The heater requires 2 watts at 5V which can be supplied by a battery or an unregulated DC supply. In an ambient of 20°C the Resistor’s heater will warm up in typically 30 minutes, and an LED shows when the temperature has been reached. A test pocket is provided so that the resistors’ temperature can be monitored if required. Stability of 0.1 ppm/month or better can be expected. Standard models are: 10, 25, 100, 1000, 10,000Ω. For other values please contact Isotech. For the highest quality traceability we recommend that the 456 be UKAS Certified. We can offer the 2 Sigma Uncertainties shown in the table.


ВимірюванняГенерація (Імітація)


Temperature Controlled Fixed Resistors

- Nominal Temperature Coefficient of Resistance: +0.02ppm/°C (with temperature control on) 18 to 25°C

- Model 456. By temperature controlling an otherwise very stable resistor a performance close to the very best available World-wide can be achieved at a surprisingly low price.

- Nominal Temperature Coefficient of Resistance: +0.02ppm/°C (with temperature control on) 18 to 25°C

- Power Rating: 0.5 Watt at +25°C

- Standard models: 10, 25, 100, 1000 and 10,000Ω

- Current Noise: <0.010µV (RMS) / Volt of Applied Voltage

- Thermal EMF: 0.1µV/°C Max; 0.05µV/°C Typical

- The most precise and stable resistors available

- Impervious to harmful environments - oil filled

Featured Products

Dryers for Humidity Calibration Systems - PSD2 and PSD4
Pressure Swing dryers provide a source of very dry compressed air for use as a zero gas in humidity calibration systems, or for general laboratory applications. The Michell PSD Series Pressure Swing Dryers use two columns filled with 4Å mo...
Код: PSD2,4
Greybody Source Model 975
Greybody Source Model 975
When the high accuracy of the Gemini R is not necessary this product offers a cost effective solution for the calibration and testing of infrared thermometers. The Greybody Model 975 gives fast accurate results with a larger sensing area. A...
Код: 975
IO620-HOSE-P2-IS Pneumatic hose in hazardous area use
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Hazardous area use 1 m/3.28 ft pneumatic hose. Maximum pressure 400 bar/5800 psi...
Код: IO620-HOSE-P2-IS
9333 SERIES of Air Resistance Standards
9333 SERIES of Air Resistance Standards
GUILDLINE INSTRUMENTS NEW 9333 SERIES of Air Resistance Standards are cost effective laboratory, portable or just general purpose resistance standards. They are very stable and are designed to be used across a wide temperature range. PRODUC...
Код: 9333
Large Volume Liquid Bath Model 820
Large Volume Liquid Bath Model 820
If you have a large number of sensors to calibrate then this economically priced stirred liquid bath is the solution. The 820 bath has been introduced to provide a liquid calibration bath with a large volume. This is to allow the bath to be...
5.0000/5 1text_less_review
Код: 820
Moisture in Natural Gas Analyzer - Michell OptiPEAK TDL600
Moisture in Natural Gas Analyzer - Michell OptiPEAK TDL600
The next generation TDLAS Analyzer for automatic online measurement of moisture in variable compositions of natural gas and biomethane. The OptiPEAK TDL600 Tuneable Diode Laser Analyzer employs the latest techniques in laser absorption spec...
Код: TDL600
AII GPR-35 Ambient Oxygen Monitors
0-25% FS ranges Accuracy < 2% of range at constant conditions Advanced Sensor Technology: • Long Life Sensor, Low maintenance with typically 32 months oxygen sensor life • Extended Operating Range • Sensitivity 0.5% Full Scale No Fals...
Код: GPR-35
P5513 Pneumatic Comparator
P5513 Pneumatic Comparator
This pneumatic comparison pressure comparator is designed for testing pressure measuring instruments against master test instruments. This cost effective instrument provides precise control for important calibration requirements and includ...
Код: P5513
Medusa R Model 999
Medusa R Model 999
The Medusa R Blackbody Calibration Source allows for calibration of noncontact infrared thermometers over the temperature range 30°C to 550°C. It is suitable for use as a radiation source for infrared thermometers. The cavity is 45 x 285mm ...
Код: 999
ADT960 Hydraulic Pressure Test Pump
ADT960 Hydraulic Pressure Test Pump
The new Additel 960 Hydraulic Pressure Test Pump is a benchtop pressure pump designed to generate pressure to 60,000 psi (4,200 bar). This pump incorporates a dual-piston system which is ideal for filling large volume workload with the hand...
Код: ADT960
3010A precision multiproduct calibrator
3010A precision multiproduct calibrator
The 3000A Series multiproduct calibrators have been designed to help you and your business, allowing a wide range of calibration work to be performed quickly, accurately and economically. Modern calibration is a competitive market, and cost...
Код: 3010A
Additel 875-1210 Thermocouple Calibration Furnaces
Additel 875-1210 Thermocouple Calibration Furnaces
We understand the many challenges associated with thermocouple calibration work. That is precisely why we decided to introduce the ADT875-1210 and ADT878-1210 Thermocouple Calibration Furnaces. With an unmatched stability, uniformity and an...
Код: ADT878-1210
PV210  Low-Pressure Pneumatic Vacuum Pump
PV210  Low-Pressure Pneumatic Vacuum Pump
The PV210 is a lightweight, yet rugged and durable, low pressure and vacuum hand pump offering exceptional fine control. Thermally insulated to eliminate hand held temperature effects and supplied with a built-in pressure relief valve to pr...
Код: PV210
7334 Series of AC/DC Air Resistance Standards
7334 Series of AC/DC Air Resistance Standards
Guildline Instruments 7334 Series of AC/DC Air Resistance Standards are designed for high accuracy resistance calibration in air, without the need for stabilization in a temperature controlled bath. PRODUCT FEATURES Typical AC/DC Error ...
Код: 7334
E-DWT 6531/6532 Electronic Deadweight Tester
E-DWT 6531/6532 Electronic Deadweight Tester
The E-DWT-H is used in the lab or instrument shop or can be taken into the field for performing in-situ calibrations and tests. This hydraulic pressure calibration system combines a high performance electronic reference pressure monitor and...
Код: E-DWT
SMF – Calibration system for flow measurement of air and other gases
SMF® – SonicMasterFlow® Highly precise flow measurement of gases and air The SMF® – SonicMasterFlow® series are calibration systems for high-precision flow measurement of air and other gases (optional) (volume and mass flows) using cr...
Код: SMF
PRTCalc
PRTCalc
PRTCalc is a free utility for those involved with PT100 platinum resistance thermometers. It allows for the accurate conversion of resistance to temperature or temperature to resistance. PRTCalc conforms with IEC 751 Amendment 2: December 1...
Код: PRTCalc
Additel 875 Dry Well Calibrator
Additel 875 Dry Well Calibrator
If you are serious about portable temperature calibration tools, then you know a good dry well calibrator is more than just a stable heat source. The Additel 875 Series Dry Well Calibrators combine excellent performance in stability, radial...
Код: ADT875-350
Gold / Platinum Thermocouple
Gold / Platinum Thermocouple
Since 1995 Isotech have been producing various designs of special Au/Pt, Pt/Pd, Pd/Au thermocouples for researchers. From our experience we can now offer the most popular of these, the Pt/Au thermocouple in a standard form. All wires are 99...
Код:
Industrial Humidity Transmitters HVAC - Rotronic HygroFlex HF3 and HF4
Industrial Humidity Transmitters HVAC - Rotronic HygroFlex HF3 and HF4
The HygroFlex3 series is ideal for all applications where good accuracy measurement of humidity and temperature is of critical importance. The transmitters can be used in a wide range of industries...
Код: HF3_HF4
Спасибо!