Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

Hyperion 4936

- -25°C to 140°C

- The Hyperion and Drago (30°C to 250°C) have large calibration volumes, 65mm x 160mm deep, which makes them ideal to use as portable liquid baths for high accuracy calibration of awkwardly shaped sensors.

- Multi Function: Six Modes including Dry Block and Liquid Bath

- 65mm Volume: Ideal Liquid Bath

- Calibrate entire measurement loop - using a heat source rather than an electrical simulator, a test instrument and sensor can be calibrated as a system

Brief specifications


More details

Need advice on which model? Dry Block Selection Guide The Hyperion and Drago (30°C to 250°C) have large calibration volumes, 65mm x 160mm deep, which makes them ideal to use as portable liquid baths for high accuracy calibration of awkwardly shaped sensors. Stirred liquid baths are suitable for temperature sensors of all types, sizes and shapes. Liquid Baths can provide smaller calibration uncertainties than dry blocks and when used with suitable reference thermometers, accuracies of up to 0.005°C can be achieved. These models are part of the award winning Isocal-6 family and with a reference probe can be used with different accessories for Dry Block, Infrared, Surface Calibration and even with ITS-90 Fixed Point Cells for uncertainties to 0.001°C. In Dry Block Mode, the large 65mm diameter block allows for the calibration of either larger probes or for calibrating many sensors simultaneously. As a Liquid bath the sensors can be placed directly into the stirred liquid thus avoiding the need for specially drilled blocks. If the liquid is directly in the block then the controller only model, or Basic (B) model, can be selected. However, instead of putting liquids directly in the block liquid containers can be used to facilitate rapid change of fluids. For greater accuracy, or when using a liquid container, Dry Block Insert, Blackbody Target or the Surface Sensor Kit a separate reference thermometer should be used to compensate for the varying offset between the controller and the accessory temperature. An ideal arrangement would be to include the handheld Isotech TTI-10 or the bench top Isotech milliK Precision Thermometer and Model 935-14-16 Semi Standard Platinum Resistance Thermometer. Alternatively the SITE or ADVANCED model can be selected; the SITE includes a temperature indicator for a reference probe. The ADVANCED also includes inputs for test thermometers, automatic temperature cycling, logging and additional sophisticated features. All models include I-Cal Easy LOG software and the ADVANCED models additionally include software to manage logged data and configure the unit, more details.


ВимірюванняГенерація (Імітація)


Hyperion 4936

- -25°C to 140°C

- The Hyperion and Drago (30°C to 250°C) have large calibration volumes, 65mm x 160mm deep, which makes them ideal to use as portable liquid baths for high accuracy calibration of awkwardly shaped sensors.

- Multi Function: Six Modes including Dry Block and Liquid Bath

- 65mm Volume: Ideal Liquid Bath

- Calibrate entire measurement loop - using a heat source rather than an electrical simulator, a test instrument and sensor can be calibrated as a system

Featured Products

Fast-Cal High
Fast-Cal High
Fast-Cal – the product range you designed During early 2004 20 experienced engineers from many parts of the world were asked to produce their ideal specification for industrial calibration. Their top ten requirements, in order of priority, ...
5.0000/5 1text_less_review
Код: High
Fast-Cal Medium
Fast-Cal Medium
Fast-Cal – the product range you designed During early 2004 20 experienced engineers from many parts of the world were asked to produce their ideal specification for industrial calibration. Their top ten requirements, in order of priority, ...
5.0000/5 1text_less_review
Код: Medium
99100A Capacitance Reference System
Guildline Instruments 99100A Capacitance Reference System provides for ratio calibration of Capacitance Measurement Systems. The 99100A System comprises a number of highly stable hermetically sealed capacitors with a switch array and a vari...
Код: 99100A
Laminar Flow Elements
Laminar Flow Elements
Laminar Flow Elements Flow measurement elements with highest accuracy EP Ehrler Prüftechnik manufactures LFEs in the flow range from 0.012 to 4000 m³/h. In addition to the standard range, EP offers customer-specific LFEs that are perf...
Код: LFE
Michell XTC501 Thermal Conductivity Analyser
Michell XTC501 Thermal Conductivity Analyser
A lightweight and compact binary gas analyzer for measuring gas mixtures – such as air in argon or carbon dioxide in air. Suitable for installation in safe areas the XTC501 has a tough, IP55-rated housing. Available with an optional display...
Код: XTC501
ADT780 Pressure Controller
ADT780 Pressure Controller
For years, we’ve provided the most durable, accurate, quality pressure calibration products for field applications. The Additel 780 series controller incorporates the same durability, accuracy, and quality into a new bench top controller pa...
Код: ADT780
Compact Sampling System - Michell ES20
Compact Sampling System - Michell ES20
The ES20 Compact Sampling System is designed to reliably and accurately measure dew point or moisture content in a wide variety of industrial gas applications up to 20 barg. This sampling system is an economical and high-quality solution wi...
Код: ES20
9200B PORTABLE electrical tesr equipment calibrator
9200B PORTABLE electrical tesr equipment calibrator
The industry leading 3200B series provides by far the fastest and safest solution for calibration of Loop, RCD, PAT's and insulation testers. By using the 3200B series, calibration time can be drastically reduced, while superior accuracy me...
Код: 9200B
Intrinsically safe dew-point transmitter - Michell Easidew PRO I.S.
Intrinsically safe dew-point transmitter - Michell Easidew PRO I.S.
The Easidew PRO I.S. intrinsically safe dew-point transmitter measures moisture in demanding process and refinery applications in either gases or non-polar liquids. It offers a wide measurement range of –110 to +20°Cdp, is easily integra...
Код: Easidew PRO I.S.
2090 PROGRAMMABLE DECADE RESISTANCE BOX precision references and standards
Connect the 2090 via RS232 connection (USB to RS232 adapter available) to a computer to automate any task performed by a decade resistance box to automate calibration or ATE tasks. Providing a basic accuracy of up to 0.1% (0.01% accuracy op...
Код: 2090
IO620-NPT A set of test point adaptors
IO620-NPT A set of test point adaptors
A set of test point adaptors to connect the tool less quick fit PV62XG, MC620G and the extension hoses to the device under test...
Код: IO620-NPT
Dual and Heat Pipe Furnaces
Dual and Heat Pipe Furnaces
Heat Pipe Furnaces Isotech metrology furnaces have more than 35 years of proven use and are widely used by the worlds’ leading NMIs. For the optimal use of fixed point cells the temperature uniformity should be less than 10mK over the lengt...
Код:
RH and Temperature Probe Calibrator - Rotronic HygroGen 2
RH and Temperature Probe Calibrator - Rotronic HygroGen 2
The HygroGen2 is a generator of controlled relative humidity and temperature environments, primarily for use in calibrating humidity instrumentation, but is also well suited to the calibration of temperature instrumentation, particularly ...
Код: HG2
Moisture in Liquid Analyzer - Michell Liquidew I.S.
Moisture in Liquid Analyzer - Michell Liquidew I.S.
Intrinsically safe moisture in liquids analyzer for fast, reliable on-line measurements. Continuous online measurement allows monitoring and control of processes to maximise efficiency for production and maintenance. Based on the Michell C...
Код: Liquidew I.S.
Blackbody Source Model 989
Blackbody Source Model 989
Isotech first introduced the Model 988 to assist in relation to the SARS outbreak during the early 2000s. Used to increase the accuracy of thermal imagers being used to measure human skin temperature in temperature screening of applications...
5.0000/5 2text_more_review
Код: 989
Fast-Cal Low
Fast-Cal Low
Fast-Cal – the product range you designed During early 2004 20 experienced engineers from many parts of the world were asked to produce their ideal specification for industrial calibration. Their top ten requirements, in order of priority, ...
Код: Low
Flexible Current Transformer FCT 2161
Flexible Current Transformer FCT 2161
Precision Flexible AC Current Transformer SymmProFlex® FCT 2161 is based on Rogowski principle designed to measure alternating current and to transform the measured current to standardized 5 A level...
Код: 2161
Cryostat Model 459
Cryostat Model 459
When we considered low temperature comparison calibration, we had to take into account Health and Safety considerations, both of the liquids used in compressors to generate low temperatures and also the liquids used in the calibration volum...
4.6667/5 3text_more_review
Код: 460
Moisture in Natural Gas Analyzer - Michell OptiPEAK TDL600
Moisture in Natural Gas Analyzer - Michell OptiPEAK TDL600
The next generation TDLAS Analyzer for automatic online measurement of moisture in variable compositions of natural gas and biomethane. The OptiPEAK TDL600 Tuneable Diode Laser Analyzer employs the latest techniques in laser absorption spec...
Код: TDL600
IO620-BSP  A set of test point adaptors
IO620-BSP  A set of test point adaptors
A set of test point adaptors to connect the tool less quick fit PV62XG, MC620G and the extension hoses to the device under test...
Код: IO620-BSP
Спасибо!