Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

RBC Resistance Bridge Calibrators

- Temperature Coefficient: < ±0.3 ppm/ °C.

- The problem: Temperature measurement is one of the most demanding applications of resistance measurement. Calibrate thermometry bridges quickly, simply and in-house

- Calibrate ac and dc thermometry bridges

- High accuracy - better than 0.01 ppm at 100 Ohms (RBC100A)

- Patented design licensed from IRL

- Windows application for full analysis and reporting

Brief specifications


More details

Operating principles The problem: Temperature measurement is one of the most demanding applications of resistance measurement. It requires the measurement of resistance ratios to accuracies of 0.1ppm or better. While dc resistance standards are sometimes available at this level, ac resistance standards are generally not. So how can we show our bridges are accurate at this level, and that our resistance and temperature measurements are traceable? The linearity check One simple method for checking a resistance bridge is to measure a pair of resistors separately, and then measure the two in series. Ideally the series measurement should equal the sum of the two individual measurements. If not, then the measurements give us a bit of information about the errors in the bridge readings. Note that we do not need to know the values of the resistors to make this test work. The complement check Another check is to measure the ratio of two resistances, say R1/R2, then swap the resistors and measure the reciprocal ratio (or complement), R2/R1. Ideally the product of the two measurements should equal 1.0 exactly, if not, the measurements give us more information on the bridge errors. Once again, we do not need to know the values of the resistors to make this test work. The combinatorial method The RBC exploits the same principles as the linearity and complement check. It uses a network of four stable four terminal resistors that can be connected in 35 different series and parallel combinations. By measuring each RBC combination in the two different ways (as with the complement check) up to 70 different measurements can be made. Since the RBC has just four unknown resistance values, we have up to 66 independent measurements containing information about the errors in the bridge readings. The combinatorial calibration method is particularly powerful because it is not necessary to know the actual values of the four resistors, or their frequency dependence. This means we can calibrate any ac or dc bridge to any accuracy, so long as the various resistance combinations are accurate. The patented RBC Calibrators are a result of research carried out by Rod White at the Measurement Standards Laboratory of New Zealand, which operates within Industrial Research Ltd (IRL). Isothermal Technology Ltd has an exclusive licence from IRL to develop, sell and produce the RBC. Introducing the RBC


ВимірюванняГенерація (Імітація)


RBC Resistance Bridge Calibrators

- Temperature Coefficient: < ±0.3 ppm/ °C.

- The problem: Temperature measurement is one of the most demanding applications of resistance measurement. Calibrate thermometry bridges quickly, simply and in-house

- Calibrate ac and dc thermometry bridges

- High accuracy - better than 0.01 ppm at 100 Ohms (RBC100A)

- Patented design licensed from IRL

- Windows application for full analysis and reporting

Featured Products

P3200 Hydraulic Deadweight Tester
P3200 Hydraulic Deadweight Tester
The P3000 Series is the culmination of over 50 years experience in the production and design of primary pressure standards. With features designed to improve accuracy and performance, increase reliability and simplify operation these deadwe...
Код: P3200
Humidity Validator - Michell HygroCal100
Humidity Validator - Michell HygroCal100
The HygroCal100 provides a stable test chamber to quickly evaluate the performance of relative humidity sensors across a wide range of 5 to 95% relative humidity. Its intuitive 4” touch screen display and interface allows the probes under ...
Код: HygroCal100
Pegasus R Model 970
Pegasus R Model 970
The Pegasus R is a compact furnace for calibrating radiation pyrometers. The temperature of the furnace is set on a controller, whilst an independent indicator, whose sensor fits into the cavity, indicates the actual radiance temperature. T...
Код: 970
PV212 Hydraulic Pressure Test Pump
PV212 Hydraulic Pressure Test Pump
The PV212 is a high-quality hand pump designed to quickly and easily generate hydraulic pressures. The construction materials make it compatible with most fluid media and an optional seal kit can be supplied for many applications. The built...
Код: PV212
VMF – Measuring system for high-precision flow measurement of air or gas
VMF® – VenturiMasterFlow® Flow measurement of air and gases We develop and manufacture venturi tubes and nozzles as individual components or as complete VMF® systems. The VenturiMasterFlow® measuring system, or VMF® for short, is used...
Код: VMF
PACE6000 Pressure Controller
PACE6000 Pressure Controller
The Pneumatic Druck PACE5000 / PACE6000 Modular Pressure Controllers bring together the latest control and measurement technology to offer an elegant fast flexible and economical solution to pressure control for automated production, test a...
Код: PACE6000
RPS/DPS8000 Series  High-Accuracy Resonant Pressure Sensor
RPS/DPS8000 Series  High-Accuracy Resonant Pressure Sensor
The RPS/DPS 8000 is the first product to incorporate the exciting new TERPS technology. TERPS is a resonant silicon pressure sensor technology platform that provides an order of magnitude greater accuracy and stability than current pressure...
Код: RPS/DPS8000
Dew-Point Transmitter - Michell Easidew 34
The Easidew 34 is a dew-point transmitter with a 3/4” process connection. Designed for use in industrial conditions, it has a wide measurement range from -110 to + 20 °C dew point. Based on Ceramic Metal-Oxide Moisture Sensor the Easidew 3...
Код: Easidew 34
Local Evaluation Unit OPS
Local Evaluation Unit OPS
The Local Evaluation Unit OPS is a local microcomputer designed for comparison of reference impulses coming from the standard meter with optical impulses or reflexes from the black mark on the disk of the meter. Value of the measured error ...
Код: Unit OPS
AII GPR-35 Ambient Oxygen Monitors
0-25% FS ranges Accuracy < 2% of range at constant conditions Advanced Sensor Technology: • Long Life Sensor, Low maintenance with typically 32 months oxygen sensor life • Extended Operating Range • Sensitivity 0.5% Full Scale No Fals...
Код: GPR-35
IO620-HOSE-H2 High pressure hydraulic hose
A high pressure hydraulic hose rated to 1,000 bar (15,000 psi) and terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. The hose is self sealing to avoid leakage...
Код: IO620-HOSE-H2
Meteorology RH and T Probes - Rotronic MP100A/MP400A
The MP100A is a combined humidity and temperature probe designed primarily for meteorological and general outdoor applications. Operation from DC voltage and low power consumption make the MP101A particularly suitable for operation at remot...
Код: MP100A/MP400A
DG2, DG3, DG4 and VDS3 - Michell Dew-Point Generators
DG2, DG3, DG4 and VDS3 - Michell Dew-Point Generators
The Michell range of dew-point generators provides flexibility and control at a competitive price. Based on the volumetric mixing of dry and wet gases, the instruments can be controlled either manually or automatically to suit a wide range ...
Код: DG
Rotronic CO2 Display for Indoor Air Quality Monitoring (CL11, CP11)
Rotronic CO2 Display for Indoor Air Quality Monitoring (CL11, CP11)
Indoor Air Quality (IAQ) measurements in offices, conference rooms, schools, etc. Application range: 0...50 °C / 0...95 %rh, non-condensing CO2 Measurement principle: Infrared (NDIR) with automatic calibration (ABC) CO2 Display Wal...
Код: CL11_ CP11
Miniature Fixed Resistor Model 836
Isotech produces a miniature resistor with ultra-low temperature coefficient and ultra-high stability. This is achieved because the resistors are oil filled and hermetically sealed. The function of hermetic sealing is to eliminate the ingre...
Код: 836
RPM4 Reference Pressure Monitor
RPM4 Reference Pressure Monitor
RPM4 is much more than a traditional pressure indicator State of the art performance from very low pressure to 280 MPa (40 000 psi)… advanced on-board features…compact and rugged…full local and remote communications…RPM4 is the perfect sol...
Код: RPM4
GL1050 Series of Resistance Transfer Standards
GL1050 Series of Resistance Transfer Standards
Guildline Instruments GL 1050 Series of Resistance Transfer Standards are designed as very high stability calibration laboratory transfer standards for customers looking to replace the old ESI SR1050 Series. PRODUCT FEATURES Very High Quali...
Код: GL1050
Additel 875-1210 Thermocouple Calibration Furnaces
Additel 875-1210 Thermocouple Calibration Furnaces
We understand the many challenges associated with thermocouple calibration work. That is precisely why we decided to introduce the ADT875-1210 and ADT878-1210 Thermocouple Calibration Furnaces. With an unmatched stability, uniformity and an...
Код: ADT878-1210
2465A Gas Piston Gauge
2465A Gas Piston Gauge
The Model 2465 Gas Piston Gauge has a long history of serving national standards laboratories, commercial industry and government organizations as a primary pressure standard for over 40 years. Since its original introduction, enhancements ...
Код: 2465A
Cryostat Model 459
Cryostat Model 459
When we considered low temperature comparison calibration, we had to take into account Health and Safety considerations, both of the liquids used in compressors to generate low temperatures and also the liquids used in the calibration volum...
4.6667/5 3text_more_review
Код: 460