RBC Resistance Bridge Calibrators

- Temperature Coefficient: < ±0.3 ppm/ °C.

- The problem: Temperature measurement is one of the most demanding applications of resistance measurement. Calibrate thermometry bridges quickly, simply and in-house

- Calibrate ac and dc thermometry bridges

- High accuracy - better than 0.01 ppm at 100 Ohms (RBC100A)

- Patented design licensed from IRL

- Windows application for full analysis and reporting

Brief specifications


More details

Operating principles The problem: Temperature measurement is one of the most demanding applications of resistance measurement. It requires the measurement of resistance ratios to accuracies of 0.1ppm or better. While dc resistance standards are sometimes available at this level, ac resistance standards are generally not. So how can we show our bridges are accurate at this level, and that our resistance and temperature measurements are traceable? The linearity check One simple method for checking a resistance bridge is to measure a pair of resistors separately, and then measure the two in series. Ideally the series measurement should equal the sum of the two individual measurements. If not, then the measurements give us a bit of information about the errors in the bridge readings. Note that we do not need to know the values of the resistors to make this test work. The complement check Another check is to measure the ratio of two resistances, say R1/R2, then swap the resistors and measure the reciprocal ratio (or complement), R2/R1. Ideally the product of the two measurements should equal 1.0 exactly, if not, the measurements give us more information on the bridge errors. Once again, we do not need to know the values of the resistors to make this test work. The combinatorial method The RBC exploits the same principles as the linearity and complement check. It uses a network of four stable four terminal resistors that can be connected in 35 different series and parallel combinations. By measuring each RBC combination in the two different ways (as with the complement check) up to 70 different measurements can be made. Since the RBC has just four unknown resistance values, we have up to 66 independent measurements containing information about the errors in the bridge readings. The combinatorial calibration method is particularly powerful because it is not necessary to know the actual values of the four resistors, or their frequency dependence. This means we can calibrate any ac or dc bridge to any accuracy, so long as the various resistance combinations are accurate. The patented RBC Calibrators are a result of research carried out by Rod White at the Measurement Standards Laboratory of New Zealand, which operates within Industrial Research Ltd (IRL). Isothermal Technology Ltd has an exclusive licence from IRL to develop, sell and produce the RBC. Introducing the RBC


ВимірюванняГенерація (Імітація)


RBC Resistance Bridge Calibrators

- Temperature Coefficient: < ±0.3 ppm/ °C.

- The problem: Temperature measurement is one of the most demanding applications of resistance measurement. Calibrate thermometry bridges quickly, simply and in-house

- Calibrate ac and dc thermometry bridges

- High accuracy - better than 0.01 ppm at 100 Ohms (RBC100A)

- Patented design licensed from IRL

- Windows application for full analysis and reporting

Featured Products

Hydrocarbon Dew-Point Analyzer - Michell Condumax II
Hydrocarbon Dew-Point Analyzer - Michell Condumax II
The Condumax II hydrocarbon and water dew-point analyzer provides continuous, automatic measurements of these two critical parameters of natural gas quality. It uses the ‘Dark Spot’ direct chilled-mirror technique to measure hydrocarbon dew...
Код: Condumax II
ITS-90 Optimal Fixed Point Cells
ITS-90 Optimal Fixed Point Cells
Isotech Ultra Pure-Metal Freezing Point Cells are designed specifically to realize the liquid-solid equilibrium temperatures of certain high-purity metal elements, for calibration of thermometers at the ITS-90 Fixed Points. When you purchas...
Код: ITS-90
IDOS Intelligent Digital Output Sensors
IDOS Intelligent Digital Output Sensors
IDOS (Intelligent Digital Output Sensor) are smart, Universal Pressure Modules that are interchangeable between any IDOS compatible Druck instruments. They are truly “Plug and Play” modules in that they do not require calibration or set-up ...
Код: IDOS
8500 Low Thermal 10 Channel Scanner low thermal scanner
8500 Low Thermal 10 Channel Scanner low thermal scanner
Automation of measurements using the 8500 Low Thermal Scanner allows a completely automated measurement system to be realised. Using the 8500 Scanner together with ProGraph software and the 8000 series multimeter provides a turnkey solution...
4.0000/5 1text_less_review
Код: 8500
Mercury Triple Point Apparatus
The Isotech Model ITL-M-17725 apparatus is a self-contained, mechanically-refrigerated, system with a main well to house one mercury cell and two auxiliary wells for pre-chilling of thermometers. The cryostat temperature is adjustable from ...
Код:
microK Precision Thermometry Bridge
microK Precision Thermometry Bridge
The microK 70 and 125 models are designed for the Primary Temperature Laboratories whilst the microK 250 and 500 models were designed for the Secondary Laboratory as well as a wide range of high accuracy industrial and scientific calibratio...
3.0000/5 4text_more_review
Код: croK
PACE1000 Precision Pressure Indicator
PACE1000 Precision Pressure Indicator
The Druck PACE1000 precision pressure indicator brings together the latest measurement technology to offer an elegant, fast, flexible and economical solution to pressure measurement for test, calibration and monitoring. PACE employs digital...
Код: PACE1000
TTI-7+
This instrument has now been replaced by the superior milliK Precision Thermometer The TTI-7 PLUS is a very high accuracy multi purpose digital thermometer for both platinum resistance thermometers and thermocouples. Laboratory users will w...
5.0000/5 1text_less_review
Код: TTI-7+
AII GPR-1000 Portable PPM Oxygen Analyzer
Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in the...
Код: GPR-1000
Orion Model 796L
Orion Model 796L
The Isotech Hydra range of calibration baths have proved very successful since their introduction in 2003. The Orion range has been introduced to fit alongside the Hydra models. The Orion calibration baths offer deeper calibration volumes t...
Код: 796L
IO620-CASE-4 Modular systerm transit case
Modular system transit case (P/N IO620-CASE-4) A rigid transit case with wheels and an extendable handle. Accommodates two PV62XG pressure stations, DPI620G, MC620G and PM620 modules, with ample storage space for accessories. Size: 736 mm x...
Код: IO620-CASE-4
ADT925 Hydraulic Pressure Test Pump
ADT925 Hydraulic Pressure Test Pump
The 925 Hydraulic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 85% vacuum to 6,000psi (400bar). With the patented screw press technology, the high pressure can be easily generated, as well as increa...
Код: ADT925
Oberon R Model 426
Oberon R Model 426
The Oberon R uses a Sodium heat Pipe to ensure an exceptionally low temperature gradient along the furnace core. It is ideal for the realization of Aluminium, Silver or Copper ITS-90 Fixed Points. It may be used as a blackbody source over t...
Код: 427
Standard Thermocouple Model 1600 NCJ
Standard Thermocouple Model 1600 NCJ
The Isothermal range of Thermocouple Standards are the result of many years development. The type R and S standards will cover the range from 0°C to 1600°C. The measuring assembly comprises a 7mm x 300mm or 600mm gas tight 99.7% recrystalli...
4.5000/5 2text_more_review
Код:
Humidity Temperature Probes - Rotronic HC2-HK/C
HC2-HK25 / HC2-HK40 The handheld probe is especially suitable for mobile measurements of high temperatures. It measures humidity and temperature and calculates the dew/frost point. Applications Climatic and temperature chambers, dryers, ...
Код: HC2-HK/C
3000ZR precision zener reference precision references & standards
3000ZR precision zener reference precision references & standards
The 3000ZR is an integrated 1.018V and 10V reference standard using multiple independent zeners. Backup power is provided via an internal rechargeable battery for transportation for calibration and use in your laboratory. The 3000ZR is fitt...
Код: 3000ZR
9334A SERIES of Resistance Standards
9334A SERIES of Resistance Standards
GUILDLINE INSTRUMENTS 9334A SERIES of Resistance Standards are designed as very stable laboratory standards for high accuracy resistance calibration in air, without the need for a temperature controlled bath. PRODUCT FEATURES 12 Month Stabi...
Код: 9334A
Humidity Temperature Probes - Rotronic HC2A-IC/IM/IE
Humidity Temperature Probes - Rotronic HC2A-IC/IM/IE
The HC2A series are digital humidity-temperature probes based on the AirChip3000 technology. These probes feature a UART serial interface and two 0…1 V linear analog output signals. The HC2A probes are designed for use with the HygroClip2...
Код: HC2A-IC/IM/IE
Dual and Heat Pipe Furnaces
Dual and Heat Pipe Furnaces
Heat Pipe Furnaces Isotech metrology furnaces have more than 35 years of proven use and are widely used by the worlds’ leading NMIs. For the optimal use of fixed point cells the temperature uniformity should be less than 10mK over the lengt...
Код:
ADT226 Multifunction Calibrator
ADT226 Multifunction Calibrator
Additel’s new Multi-functional Process Calibrator series takes portability, functionality, and accuracy to a whole new level and packages it with an intuitive and easy to use color touchscreen display. The ADT226 is a powerful yet cost effe...
Код: ADT226
Спасибо!