Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

Temperature Controlled Fixed Resistors

- Nominal Temperature Coefficient of Resistance: +0.02ppm/°C (with temperature control on) 18 to 25°C

- Model 456. By temperature controlling an otherwise very stable resistor a performance close to the very best available World-wide can be achieved at a surprisingly low price.

- Nominal Temperature Coefficient of Resistance: +0.02ppm/°C (with temperature control on) 18 to 25°C

- Power Rating: 0.5 Watt at +25°C

- Standard models: 10, 25, 100, 1000 and 10,000Ω

- Current Noise: <0.010µV (RMS) / Volt of Applied Voltage

- Thermal EMF: 0.1µV/°C Max; 0.05µV/°C Typical

- The most precise and stable resistors available

- Impervious to harmful environments - oil filled

Brief specifications


More details

By temperature controlling an otherwise very stable resistor a performance close to the very best available World-wide can be achieved at a surprisingly low price. The resistor itself is oil filled and hermetically sealed. The function of hermetic sealing is to eliminate the ingress of moisture and oxygen both of which play a role in the long term degradation of unsealed resistors. A further enhancement in both short and long term stability is achieved by oil filling. The oil also acts as a thermal conductor allowing the device to accept short periods of overload without degradation. With accuracies of ±0.005%, a wide resistance range and long term drift of less than 5ppm, these devices are virtually secondary standards that can be kept in a laboratory as references to calibrate other devices. The Resistor is held in a temperature controlled environment heated to 30°C ±0.1°C other temperatures are available to special order. The heater requires 2 watts at 5V which can be supplied by a battery or an unregulated DC supply. In an ambient of 20°C the Resistor’s heater will warm up in typically 30 minutes, and an LED shows when the temperature has been reached. A test pocket is provided so that the resistors’ temperature can be monitored if required. Stability of 0.1 ppm/month or better can be expected. Standard models are: 10, 25, 100, 1000, 10,000Ω. For other values please contact Isotech. For the highest quality traceability we recommend that the 456 be UKAS Certified. We can offer the 2 Sigma Uncertainties shown in the table.


ВимірюванняГенерація (Імітація)


Temperature Controlled Fixed Resistors

- Nominal Temperature Coefficient of Resistance: +0.02ppm/°C (with temperature control on) 18 to 25°C

- Model 456. By temperature controlling an otherwise very stable resistor a performance close to the very best available World-wide can be achieved at a surprisingly low price.

- Nominal Temperature Coefficient of Resistance: +0.02ppm/°C (with temperature control on) 18 to 25°C

- Power Rating: 0.5 Watt at +25°C

- Standard models: 10, 25, 100, 1000 and 10,000Ω

- Current Noise: <0.010µV (RMS) / Volt of Applied Voltage

- Thermal EMF: 0.1µV/°C Max; 0.05µV/°C Typical

- The most precise and stable resistors available

- Impervious to harmful environments - oil filled

Featured Products

Extension Cables for Rotronic Humidity Probes HC2-A and HC2
Extension Cables for Rotronic Humidity Probes HC2-A and HC2
The HC2-A extension cables extend the HC2-A probes away from transmitters, handheld instruments or data loggers and data loggers. The HC2-A extension cables can be used up to 5 meters...
Код: HC2
Isorac Model 844
Isorac Model 844
The function of this reference unit differs from other rack mounted systems in that the temperature of the metal block in which the thermocouple and copper leads are inserted actually varies with ambient temperature. A separate output signa...
Код: 845
ADT960 Hydraulic Pressure Test Pump
ADT960 Hydraulic Pressure Test Pump
The new Additel 960 Hydraulic Pressure Test Pump is a benchtop pressure pump designed to generate pressure to 60,000 psi (4,200 bar). This pump incorporates a dual-piston system which is ideal for filling large volume workload with the hand...
Код: ADT960
Water Activity Probe - Rotronic HC2-AW
Water Activity Probe - Rotronic HC2-AW
The ROTRONIC probe type HC2-AW-(USB) measures the humidity and the temperature of hygroscopic products. The digital probe signal is processed by an indicator such as the HygroLab C1 or the HP23- AW-A, or from a pc (HC2-AW-USB)...
Код: HC2-AW
HPPP480 Calibration system for gas meters with natural gas
HPPP480 Calibration system for gas meters with natural gas The calibration system serves as a standard for the calibration of gas meters of natural gas. The supply of natural gas occurs directly from a pipeline. The gas used for calibrat...
Код: HPPP480
PG7202 High Pressure Gas/Hydraulic Piston Gauge
PG7202 High Pressure Gas/Hydraulic Piston Gauge
The piston gauge’s fundamental operating principle and excellent long term stability have made it an indispensable tool in high accuracy pressure metrology. As accuracy levels increase, quality assurance requirements intensify and automatio...
Код: PG7202
DPI800/802 Pressure Indicator /Loop Calibrator
DPI800/802 Pressure Indicator /Loop Calibrator
DPI 800/802 Druck Pressure Indicator/Loop Calibrator The DPI 800 Series is a complete range of advanced, robust and simple to use hand-held instruments. Highly cost effective, these tools are ideal for test/calibration of many popular proce...
Код: DPI800/802
TRU Model 938
TRU Model 938
The TRU (Thermocouple Reference Unit) supplies a stable and accurate 0°C, or elevated reference temperature. It is a self-contained all solid-state unit using Peltier technology which provides maintenance free operation. The TRU features ra...
Код: 938
ADT946A Hydraulic Pressure Test Pump
ADT946A Hydraulic Pressure Test Pump
The new Additel 946A Hydraulic Pressure Test Pump is a benchtop pressure pump designed to generate pressure to 15,000 psi (1,000 bar). This pump incorporates a dual-piston system which is ideal for filling large volume workload with the han...
Код: ADT946A
Multi Junction Laboratory Probes
Multi Junction Laboratory Probes
Probes are suitable for use with all Isotech thermocouple reference units or may be used with any other equipment including ice flasks and ice point reference units. They can be supplied to suit a single thermocouple, or up to ten double ju...
Код:
H8000 Relative Humidity Element
The H8000 capacitive polymer element is the latest generation technology, developed to reliably and accurately measure moisture in a wide range of relative humidity applications. This element is the core measurement element of Michell’s ne...
Код: H8000
ADT104-HP Set of Adapters and Fittings
ADT104-HP Set of Adapters and Fittings
The Additel ADT104-HP is a high-pressure adapter kit designed to support various calibration and pressure testing needs. It includes a set of 17 adapters with a 1/4HP male (Autoclave M-250-C) connection, compatible with Additel models such ...
Код: ADT104
Additel 875-1210 Thermocouple Calibration Furnaces
Additel 875-1210 Thermocouple Calibration Furnaces
We understand the many challenges associated with thermocouple calibration work. That is precisely why we decided to introduce the ADT875-1210 and ADT878-1210 Thermocouple Calibration Furnaces. With an unmatched stability, uniformity and an...
Код: ADT875-1210
INSERTION PROBES HYGROCLIP2 HC2-P05/HP28
The insertion probe is suitable for measurement in dust-free bulk materials, bricks, concrete, etc (10 mm insertion probe: measurements in dusty bulk materials such as flour, sugar, etc.). It measures humidity and temperature and calculates...
Код: HC2-P05/HP28
POTTS – Medusa Model 510 & 511
Isotech have a wide range of Dry Blocks to suit probes requiring a large immersion depth. These products feature large and deep calibration volumes. As such they are less portable than the earlier Dry Blocks, but have higher capacities and ...
5.0000/5 1text_less_review
Код: 510 & 511
Weather Shields - Rotronic AC Series
Weather Shields - Rotronic AC Series
Naturally ventilated shields are used where the natural ventilation (wind) suffices, e.g. measurement stations in the mountains...
Код: AC
P5523 Liquid-to-Gas Media Separator
For high pressure pneumatic calibrations this unit interfaces with hydraulic deadweight testers providing a rateless liquid-to gas separation. Driven by a pneumatic pressure source (nitrogen bottle) and controlled by needle valves, high pre...
Код: P5523
Additel 878 Reference Dry Well Calibrator
Additel 878 Reference Dry Well Calibrator
Additel takes temperature calibration to the next level with the ADT878 reference dry block calibrators. If you're looking for the best dry-block calibrator on the market, you've found it! Additel's commitment to continuous improvement, qua...
Код: ADT878-425
Dew-Point Transmitter - SF82
Dew-Point Transmitter - SF82
The SF82 is a fast-responding moisture sensor for control of dew point and moisture content in compressed air dryers to maximize energy efficiency. Compressor rooms are often hot with temperatures reaching +50 °C. The SF82 is capable of rel...
Код: SF82
8 Way Selector Switches Models 954 and 958
8 Way Selector Switches Models 954 and 958
Isotech produces two eight way selector switches, one for resistance thermometers Model 954 and Model 958 for thermocouples. These switches have been designed for use in conjunction with our TTI range. The switches allow easy selection of c...
Код: 958