Gallium Fixed Point Apparatus

- Automate your Gallium point Model 17402B Gallium Apparatus is not an adaptation from general purpose equipment, but is designed specifically to realise and maintain the Gallium Cell on the melt plateau, for calibration of thermometers on the International Temperature Scale of 1990.

- Simple, automatic and safe operation

- Reproducibility day-to-day of ±0.000025°C

- 20 years of world-wide deliveries without breakage

- 99.999999% purity

Brief specifications


More details

Model 17402B Gallium Apparatus is not an adaptation from general purpose equipment, but is designed specifically to realize and maintain the Gallium Cell on the melt plateau, for calibration of thermometers on the International Temperature Scale of 1990. The apparatus will permit the gallium to melt coaxially over 12 to 16 hours. It is uniquely designed to also freeze the cell from the bottom up, which eliminates the danger of damage due to the expansion of gallium during freezing. Model 17401 Gallium Cell may be used in a well controlled bath without the need for the thermal environment provided by Model 17402B Gallium Apparatus. However, because of the advantages of automatic operation, convenience and cell protection, Isotech recommend the use of the Model 17402B environment in most cases. No external connections other than power are required. A completely automatic electronic control system provides a precise means for realization and maintenance of the plateau. The Apparatus can be turned on by a timer an hour before the laboratory day begins, the plateau utilized throughout the working day and the system recycled overnight. A thermal sink is provided which forces the gallium to refreeze upwards from the bottom (gallium expands when it freezes, requiring a specific freeze orientation to avoid rupturing the cell). Confidence is a major requirement in a standard. The Isothermal Gallium Cell and Apparatus have a long (20 year) history and have been successfully used in most National and Primary Laboratories world-wide. This is one of the main reasons for choosing the Isothermal Cell and Apparatus. The Cell and Apparatus are manufactured to the strict requirements of BS 5750 and ISO 9000. Each finished unit becomes part of the Isotech UKAS working Calibration Laboratory for two weeks or more, during which use the control circuits are set and checked for optimum performance. It is released only when Isotech are entirely satisfied with its performance.


ВимірюванняГенерація (Імітація)


Документация

Gallium Fixed Point Apparatus

- Automate your Gallium point Model 17402B Gallium Apparatus is not an adaptation from general purpose equipment, but is designed specifically to realise and maintain the Gallium Cell on the melt plateau, for calibration of thermometers on the International Temperature Scale of 1990.

- Simple, automatic and safe operation

- Reproducibility day-to-day of ±0.000025°C

- 20 years of world-wide deliveries without breakage

- 99.999999% purity

Featured Products

8400B “Autosal” Laboratory Salinometer
8400B “Autosal” Laboratory Salinometer
The 8400B “Autosal” Laboratory Salinometer is the “Industry Standard” for salinity measurements. A very stable temperature control bath and heat exchanger maintain the sample at a precisely defined temperature during analysis, avoiding the ...
Код: 8400B
IO620-CASE-2 Carrying case
IO620-CASE-2 Carrying case
System carrying case Protective carrying case for system components including the DPI620G, MC620G, PM620 modules, test leads, hose and adaptors...
Код: IO620-CASE-2
Stirred Ice Bath Model 813
Stirred Ice Bath Model 813
The most used temperature for calibration is 0°C. The normal way of creating 0°C is via a mixture of ice and water in a Dewar Flask. However, this can give errors of up to 4°C because water is densest at 4°C and so as the ice melts the temp...
Код: 813
POTTS – Medusa Model 510 & 511
Isotech have a wide range of Dry Blocks to suit probes requiring a large immersion depth. These products feature large and deep calibration volumes. As such they are less portable than the earlier Dry Blocks, but have higher capacities and ...
5.0000/5 1text_less_review
Код: 510 & 511
9334A SERIES of Resistance Standards
9334A SERIES of Resistance Standards
GUILDLINE INSTRUMENTS 9334A SERIES of Resistance Standards are designed as very stable laboratory standards for high accuracy resistance calibration in air, without the need for a temperature controlled bath. PRODUCT FEATURES 12 Month Stabi...
Код: 9334A
millisKanner Channel Expander
millisKanner Channel Expander
The millisKanner channel expander has eight input channels, and each can be configured individually for SPRT, PRT, Thermistor or Thermocouple input. This gives ultimate flexibility with no need for separate devices for resistance or thermoc...
Код:
Miniature Fixed Resistor Model 836
Isotech produces a miniature resistor with ultra-low temperature coefficient and ultra-high stability. This is achieved because the resistors are oil filled and hermetically sealed. The function of hermetic sealing is to eliminate the ingre...
Код: 836
Orion Model 796L
Orion Model 796L
The Isotech Hydra range of calibration baths have proved very successful since their introduction in 2003. The Orion range has been introduced to fit alongside the Hydra models. The Orion calibration baths offer deeper calibration volumes t...
Код: 796L
H8000 Relative Humidity Element
The H8000 capacitive polymer element is the latest generation technology, developed to reliably and accurately measure moisture in a wide range of relative humidity applications. This element is the core measurement element of Michell’s ne...
Код: H8000
Humidity Temperature Probes - Rotronic HC2A-S/S3/SM
The HC2A series are digital humidity-temperature probes based on the AirChip3000 technology. These probes feature a UART serial interface and two 0…1 V linear analog output signals. The HC2A probes are designed for use with the HygroClip2...
Код: HC2A-S/S3/SM
787 Model
787 Model
The Model 787 calibrator redefines industry standards by blending industry leading performance and speed of operation within a robust design tailored for extreme conditions. The maximum operating temperature is 660°C allowing wide range of ...
Код: 786
ADT960 Hydraulic Pressure Test Pump
ADT960 Hydraulic Pressure Test Pump
The new Additel 960 Hydraulic Pressure Test Pump is a benchtop pressure pump designed to generate pressure to 60,000 psi (4,200 bar). This pump incorporates a dual-piston system which is ideal for filling large volume workload with the hand...
Код: ADT960
Heavy Duty Transmitter Temperature and Humidity - Rotronic HF73A
Heavy Duty Transmitter Temperature and Humidity - Rotronic HF73A
The HF73A transmitter series is designed for fixed installation in industrial applications where conditions are within the range of 0 to 100 %rh and -100 to 150 °C (-148 to 302 °F). The probe of the HF73A can survive exposure to temperature...
Код: HF73A
3000CS precision curent shunts precision references and standards
The 3000CS provides a precision set of current shunts for current ranges from 10mA through to 10A to provide additional ranges for multimeters that either lack sufficient accuracy at required currents, or lack the required current ranges en...
4.5000/5 14text_more_review
Код: 3000CS
6640Q QUANTUM HALL RESISTANCE (QHR) BRIDGE
6640Q QUANTUM HALL RESISTANCE (QHR) BRIDGE
GUILDLINE INSTRUMENTS 6640Q QUANTUM HALL RESISTANCE (QHR) BRIDGE has been completely redesigned to provide better uncertainties and more operational capability. PRODUCT FEATURES New Patented Toroid Design New Dual Processor Design New Dedic...
Код: 6640Q
TRU Model 938
TRU Model 938
The TRU (Thermocouple Reference Unit) supplies a stable and accurate 0°C, or elevated reference temperature. It is a self-contained all solid-state unit using Peltier technology which provides maintenance free operation. The TRU features ra...
Код: 938
PV212 Hydraulic Pressure Test Pump
PV212 Hydraulic Pressure Test Pump
The PV212 is a high-quality hand pump designed to quickly and easily generate hydraulic pressures. The construction materials make it compatible with most fluid media and an optional seal kit can be supplied for many applications. The built...
Код: PV212
Meteorology RH and T Probes - Rotronic MP100A/MP400A
The MP100A is a combined humidity and temperature probe designed primarily for meteorological and general outdoor applications. Operation from DC voltage and low power consumption make the MP101A particularly suitable for operation at remot...
Код: MP100A/MP400A
ADT680 Digital Pressure Gauge
ADT680 Digital Pressure Gauge
DISCONTINUED. RECOMMENDED REPLACEMENT ADT680A We designed the 680 series digital pressure gauges with two main objectives in mind. First, to provide an affordable digital gauge to replace mechanical gauges. If you’re looking to move from...
Код: ADT680
Industrial Grade Chilled Mirror Hygrometer - Michell Optidew 401/501
Industrial Grade Chilled Mirror Hygrometer - Michell Optidew 401/501
The Optidew 401 and Optidew 501 are fast-responding chilled mirror hygrometers utilizing the latest developments in chilled mirror technology. Ideal for use in industrial humidity control and precision laboratory applications. Available in ...
Код: Optidew