GasPro – Mobile gas sampler

- Approved sample cylinder pressure: 4…8 bar abs.

- Pressure at GasPro: 4,5…8,5 bar overpressure 

- Max. Operating Pressure: 16 bar

- Sample cylinder volume: 500 ml

- Error limit for HS calorific value: 0,112 kWh/m³

  • GasPro – Mobile gas sampler
Brief specifications

Approved sample cylinder pressure: 4…8 bar abs.

Inlet pressure at GasPro: 4,5…8,5 bar overpressure (1,5 bar higher than the selected sample cylinder pressure)

Max. Operating Pressure: 16 bar

Temperature range: -20…+50 °C

Supply voltage: 230 VAC / optional 24 VDC

Sample cylinder volume: 500 ml

Error limit for HS calorific value  (including analysis): 0,112 kWh/m³

More details

GasPro – Mobile gas sampler

Representative cyclical gas sampling to determine gas quality in the gas network.

Analysing the gas quality in the gas network is essential to monitor technical specifications and ensure correct billing. The GasPro is a mobile gas sampler, with which cyclic sampling can be carried out easily and flexibly at any point from dry gas networks. The samples are collected in a sample cylinder in the GasPro and can then be analysed in a laboratory. The GasPro allows the separation of sampling and sample analysis and is therefore more cost effective and flexible than for example fixed installed gas chromatographs.

Applications

Natural gas quality
Assessment of natural gas quality with respect to corresponding regulations (e.g. DVGW) e.g. at network interconnection points and in supply areas with feed-in involving differing gas qualities.

SmartSim-validation
Validation of gas quality tracking systems (SmartSim) – comparison of simulated gas parameters with actual analysis values via GasPro samples.

Biogas quality
Determination of gas parameters at biogas plants.

Hydrogen quality
Determination of hydrogen purity.

Process gas quality
Determination of different process gas qualities
(available process gases on request).

Official calibration regulation of gas characteristics, PTB approval

GasPro is approved by PTB (Physikalisch Technische Bundesanstalt, Germany) for use in gas parameter custody transfer assessment, e.g. for validation of gas quality tracking systems. Due to the optimized gas sampling process with the GasPro the error limit of calorific value is HS = 0.112 kWh/m³ (including analysis).


ВимірюванняГенерація (Імітація)


GasPro – Mobile gas sampler

- Approved sample cylinder pressure: 4…8 bar abs.

- Pressure at GasPro: 4,5…8,5 bar overpressure 

- Max. Operating Pressure: 16 bar

- Sample cylinder volume: 500 ml

- Error limit for HS calorific value: 0,112 kWh/m³

Featured Products

ITS-90 Optimal Fixed Point Cells
ITS-90 Optimal Fixed Point Cells
Isotech Ultra Pure-Metal Freezing Point Cells are designed specifically to realize the liquid-solid equilibrium temperatures of certain high-purity metal elements, for calibration of thermometers at the ITS-90 Fixed Points. When you purchas...
Код: ITS-90
9334A SERIES of Resistance Standards
9334A SERIES of Resistance Standards
GUILDLINE INSTRUMENTS 9334A SERIES of Resistance Standards are designed as very stable laboratory standards for high accuracy resistance calibration in air, without the need for a temperature controlled bath. PRODUCT FEATURES 12 Month Stabi...
Код: 9334A
XGA301 Industrial Gas Analyzer
XGA301 Industrial Gas Analyzer
The XGA301 Industrial gas analyzer from Michell Instruments provides a convenient platform to measure oxygen, dew point, CO2 and CH4. The analyzer can be supplied in one of two bench-mounted chassis and with up to three sensors fitted. Sta...
Код: XGA301
DPI104 Digital Pressure Gauge
DPI104 Digital Pressure Gauge
The DPI104 is a microprocessor-controlled digital pressure gauge that combines precision and functionality in a compact, robust, and simple-to-use package. The DPI 04 matches advanced silicon sensor technology with several convenient design...
Код: DPI104
3050A precision multiproduct calibrator
3050A precision multiproduct calibrator
The 3000A Series multiproduct calibrators have been designed to help you and your business, allowing a wide range of calibration work to be performed quickly, accurately and economically. Modern calibration is a competitive market, and cost...
Код: 3050A
8500 Low Thermal 10 Channel Scanner low thermal scanner
8500 Low Thermal 10 Channel Scanner low thermal scanner
Automation of measurements using the 8500 Low Thermal Scanner allows a completely automated measurement system to be realised. Using the 8500 Scanner together with ProGraph software and the 8000 series multimeter provides a turnkey solution...
4.0000/5 1text_less_review
Код: 8500
Humidity and Temperature Probe Calibrator - Michell OptiCal
Humidity and Temperature Probe Calibrator - Michell OptiCal
The OptiCal is a premium, self-contained calibrator for humidity sensors. It features an integrated chilled-mirror reference which enables the operator to perform calibrations that are traceable to national standards. The calibration chamb...
Код: OptiCal
P3000 Pneumatic Deadweight Testers
P3000 Pneumatic Deadweight Testers
The P3000 Series is the culmination of over 50 years of experience in the production and design of high performance pressure standards. With features designed to improve accuracy and performance, increase reliability and simplify operation ...
Код: P3000
GL1010 SERIES
GL1010 SERIES
GUILDLINE INSTRUMENTS GL 1010 SERIES of Resistance Transfer Standards are very stable and low uncertainty calibration laboratory standards for customers looking to replace the old ESI 1010 series. PRODUCT FEATURES Transfer Accuracy better t...
Код: GL1010
microK Channel Expander
microK Channel Expander
The microsKanner can be used with any member of the microK family to add further channels, up to a maximum of 90 expansion channels. Easy to Use: The use of plug-and-play technology means that the extra channels appear automatically on your...
Код: microK
H8000 Relative Humidity Element
The H8000 capacitive polymer element is the latest generation technology, developed to reliably and accurately measure moisture in a wide range of relative humidity applications. This element is the core measurement element of Michell’s ne...
Код: H8000
IOHOSE-NP1 Pneumatic hose
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Safe area use 1 m/3.28 ft pneumatic hose. Maximum pressure 20 bar/300 psi...
Код: IOHOSE-NP1
Model 944
Model 944
The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from the surface of the hot-plate causes a localised cold spot to be created which means that th...
Код: 944
Medusa R Model 999
Medusa R Model 999
The Medusa R Blackbody Calibration Source allows for calibration of noncontact infrared thermometers over the temperature range 30°C to 550°C. It is suitable for use as a radiation source for infrared thermometers. The cavity is 45 x 285mm ...
Код: 999
Parallel Tube Liquid Bath Model 915MWE
Parallel Tube Liquid Bath Model 915MWE
The Isotech Model 915 Liquid Bath is suitable has a wide temperature range, using silicon oils and other suitable liquids. All components in contact with the liquid are of stainless steel, and are insulated with materials which are complete...
Код: 915MWE
Annealing Furnace
Annealing Furnace
Designed to pre-warm and anneal Standard Platinum Resistance Thermometers Maintenance Free Use Automatic Temperature Cycling The Annealing Furnace, model 414, is designed to heat, anneal and cool Standard Platinum Resistance Thermometers (S...
Код:
Water Triple Point Maintenance Bath
This dedicated apparatus has more than 35 years of proven use and is widely used by the worlds’ leading NMIs. In a recent International study cells from 21 of the world’s leading laboratories were inter-compared; the study used two Isotech ...
Код: Water Triple
Diagnostic Communication Tool for Michell Easidew and Pura
A comprehensive and self-contained tool to make routine service and maintenance of the Easidew and Pura ranges of dew-point transmitters simple to carry out. The Universal Communications Kit comprises: Electronic communications platform ...
Код: Tool
CAL NotePad
CAL NotePad
The purpose of Cal NotePad (CNP) is to automatically log and display the temperature of an Isotech calibration bath together with the unit under test. Cal NotePad can be used with baths (or indicators) without PC interfaces by the user typi...
Код: ePad
Process Sampling System - Michell ES70
Moisture analyzers are only as reliable as the sample extraction, handling and conditioning techniques used. The ES70 Sampling System range offers a set of configuration options to cover all process moisture and dew-point application needs,...
Код: ES70