- Brand
- Fluke
Fluke
8270A High-Pressure Controller
The 8270A measures and controls pressures from vacuum to 44 MPa (6400 psi). It can be configured with ranges as low as 100 kPa (15 psi).
Fluke Calibration’s unique control technology enables you to use these calibrators at low or high pressures, all in the same instrument. Control precision is 0.002% of active range.
Flexible configuration options
The 8270A are modular system that can be configured with up to five measurement modules at the same time, so they can handle high pressure, low pressure, and everything in between. Three families of modules provide three levels of performance that let you set up a system matching your needs for accuracy and value.
Safety is the top priority in the design and manufacture of our pressure products, especially high-pressure pneumatic controllers. The 8270A meet all appropriate safety standards. Each unit is equipped with over-pressure protection as well as a frontpanel abort button. Pressing the abort button vents the test pressure and returns the unit to a safe condition. Additionally, an abort valve accessory allows for faster, directed vent, as well as automated venting at loss of power. High-pressure gas does have more stored energy than high-pressure oil, but it is a safe option under the right conditions. By using the 8270A with the available accessories, you have safe operation with a clean pressure media.
Calibrate without risk of contamination
The 8270A coupled with the optional CPS, can calibrate both gas-filled and liquid-filled devices without concern of contamination. With its wide pressure range coverage, one controller can accomplish the task that used to require two separate standards.
Easiest to use high-pressure standards available
Automated pressure controllers are some of the simplest, easiest-to-use pressure standards. Controlling and measuring pressure is as simple as typing in the required pressure and pressing Enter. Unlike deadweight testers, you do not need to spin weights at a particu...
8370A High-Pressure Calibrator
The 8370A measures and controls pressures from atmosphere to 107 MPa. It can be configured with ranges as low as 700 kPa.
Fluke Calibration’s unique control technology enables you to use these calibrators at low or high pressures, all in the same instrument. Control precision is 0.002% of active range. For example, an 8370A with a 70 MPa high range module and a 700 kPa low range module will be able to control pressures below 700 kPa to within ±0.014 kPa without reducing the supply pressure.
Flexible configuration options
The 8370A are modular system that can be configured with up to five measurement modules at the same time, so they can handle high pressure, low pressure, and everything in between. Three families of modules provide three levels of performance that let you set up a system matching your needs for accuracy and value.
Safety is the top priority in the design and manufacture of our pressure products, especially high-pressure pneumatic controllers. The 8370A meet all appropriate safety standards. Each unit is equipped with over-pressure protection as well as a frontpanel abort button. Pressing the abort button vents the test pressure and returns the unit to a safe condition. Additionally, an abort valve accessory allows for faster, directed vent, as well as automated venting at loss of power. High-pressure gas does have more stored energy than high-pressure oil, but it is a safe option under the right conditions. By using the 8370A with the available accessories, you have safe operation with a clean pressure media.
Calibrate without risk of contamination
The 8370A coupled with the optional CPS, can calibrate both gas-filled and liquid-filled devices without concern of contamination. With its wide pressure range coverage, one controller can accomplish the task that used to require two separate standards.
Easiest to use high-pressure standards available
Automated pressure controllers are some of the simplest, easiest-to-use pressure standard...
PG7202 High Pressure Gas/Hydraulic Piston Gauge
The piston gauge’s fundamental operating principle and excellent long term stability have made it an indispensable tool in high accuracy pressure metrology. As accuracy levels increase, quality assurance requirements intensify and automation spreads through the workplace, the piston gauge must evolve to continue to fill its essential role in the measurement system. PG7000, the first truly new, high end piston gauge introduced since the late 1970s, responds to this challenge.
PG7000 development was undertaken with four main inter-related design objectives:
• Deliver real improvements in fundamental metrological performance to assure that today’s and tomorrow’s ever increasing accuracy requirements can be supported.
• Integrate automated monitoring of environmental and instrument operating conditions with extensive on-board intelligence to provide a modern stand alone instrument that outputs fully validated reference pressures, real time, through an intuitive operator interface.
• Reduce and when possible eliminate the influence of the operator on measurements to assure more consistent performance.
• Improve piston gauge ergonomics for greater operator satisfaction and increased productivity.
The PG7000 design objectives were pursued with the refinement of existing techniques, innovative new design, process improvements and the thorough application of today's digital and information processing technologies. The result is a coherent line of piston gauges that sets a new standard for both performance and usability, redefining the state of the art in high end pressure metrology.
PG7202 is a member of the PG7000 family of reference level piston gauges that covers the range of high pressure gas up to 110 MPa (16 000 psi). Operating directly in gas avoids difficult to use liquid/gas separators that add uncertainty to the measurement process. PG7202’s gas operated, liquid lubricated piston-cylinder design overcomes the disadvantages of lubricating the pi...
P3800 Hydraulic Deadweight Testers
The Pressurements P3800 Series is the culmination of over 50 years experience in the design and manufacture of primary pressure standards. With features and options designed to improve accuracy, increase reliability, and simplify operation, the P3800 Series can be used to calibrate virtually any high pressure sensing device including transducers, transmitters, gauges or pressure switches.
Three models are available, P3830, P3840 and P3860 offering pressure ranges of 30,000, 40,000 and 60,000 psi respectively (2000, 3000 and 4000 bar). All models are available in two accuracy classes, 0.02% or 0.015% of Reading. The Series P3800 offers an accurate and economical approach to calibrating high pressure devices.
Instrument base
The Instrument base includes all items required for operation. A high quality hand pump is coupled to a 7 to 1 intensifier, allowing the operator to easily generate high pressure in the system. An oil reservoir is included so the pump to be recharged when calibrating large volume devices. A Test Station is provided for connecting the Device under Test to the P3800 Series. Adjustable feet and the level vial allow the operator to insure the instrument is level to achieve the ultimate performance. A Piston Float Reference allows the operator to determine when the piston is in the ideal, “mid float” position.
Piston/cylinder
The piston/cylinder is the “heart” of the deadweight tester. P3800 Series pistons are manufactured from tungsten carbide which provides excellent long term stability, durability, and extremely low coefficients for temperature and pressure.
Weight sets
Standard weight masses are series 3 non-magnetic stainless steel. Each mass is marked with the serial number of the instrument and the nominal pressure value. Select either psi, bar or MPa pressure units. PressCal software can be used to support additional pressure units.
Gravity correction
Gravity varies significantly with geographical locations. Each instrument can be cali...
RPM4 Reference Pressure Monitor
RPM4 is much more than a traditional pressure indicator
State of the art performance from very low pressure to 280 MPa (40 000 psi)… advanced on-board features…compact and rugged…full local and remote communications…RPM4 is the perfect solution in a wide variety of high end pressure calibration, testing and measurement applications.
SDS™ Q-RPT Self Defense System™
All Q-RPT modules up to 7 MPa (1 000 psi) include the Fluke Calibration unique Self Defense System (SDS). SDS valves automatically isolate and vent the module’s Q-RPT when it is not in use or an overpressure is about to occur. With SDS, any Q-RPT module can be left connected to pressure up to 10 MPa (1 500 psi) without needing to isolate or disconnect it.
Infinite Ranging™ and AutoRange™
Infinite Ranging gives RPM4 unprecedented versatility in adapting to the specific range of operation. With the easy to use AutoRange function, a few simple key strokes or a single remote command string at the start of a test adapt every feature of the pressure monitor to optimize it for the range to be covered. Just enter the maximum pressure and the measurement mode.
AutoRange then:
• Selects and activates the most appropriate Q-RPT to cover the specified range and measurement mode.
• Sets the pressure unit of measure.
• Activates absolute, gauge or compound gauge measurement.
• Adjusts display resolution to the appropriate level for the range.
• Adjusts overpressure alarms to the actual range of operation.
• Reduces measurement uncertainty proportionally to the selected range (premium class Q-RPTs only).
Quartz reference pressure transducer (Q-RPT) modules
RPM4’s outstanding pressure measurement specifications are made possible by DHI's exclusive quartz reference pressure transducer (Q-RPT) modules.
Q-RPTs measure pressure by measuring the change in the natural oscillating frequency of a quartz crystal with pressure induced stress. To be qualified for use in a Q-RPT module, each transducer is individually ...
The piston gauge’s fundamental operating principle and excellent long term stability have made it an indispensable tool in high accuracy pressure metrology. As accuracy levels increase, quality assurance requirements intensify and automation spreads through the workplace, the piston gauge must evolve to continue to fill its essential role in the measurement system. PG7000, the first truly new, high end piston gauge introduced since the late 1970s, responds to this challenge.
PG7000 development was undertaken with four main inter-related design objectives:
• Deliver real improvements in fundamental metrological performance to assure that today’s and tomorrow’s ever increasing accuracy requirements can be supported.
• Integrate automated monitoring of environmental and instrument operating conditions with extensive on-board intelligence to provide a modern stand alone instrument that outputs fully validated reference pressures, real time, through an intuitive operator interface.
• Reduce and when possible eliminate the influence of the operator on measurements to assure more consistent performance.
• Improve piston gauge ergonomics for greater operator satisfaction and increased productivity.
The PG7000 design objectives were pursued with the refinement of existing techniques, innovative new design, process improvements and the thorough application of today's digital and information processing technologies. The result is a coherent line of piston gauges that sets a new standard for both performance and usability, redefining the state of the art in high end pressure metrology.
PG7302 is recommended for covering gauge and absolute pressure with oil as the pressurized medium. Absolute mode is supported by automated measurement and addition of atmospheric pressure using PG7302’s internal barometer or any external barometer supporting RS232 communications. To cover gas pressures under 11 MPa (1 600 psi), see PG7202 and PG7601.
Features
Includ...
PPCH™, is a pressure generator/controller/calibrator for liquid pressure operation from 1 to 200 MPa. As with the rest of the Fluke Calibration PPC family of pressure controllers, the emphasis is on high end performance, minimizing measurement uncertainty and maintaining precise control over a very wide pressure range—in a compact and rugged instrument.
New, individually characterized, quartz reference pressure transducer (Q-RPT) modules increase precision and reduce measurement uncertainty. The AutoRange™ feature supports infinite ranging, automatically optimizing all aspects of operation for the exact range to be explored and taking pressure controller rangeability to a new level.
A unique pressure generation and control system provides unlimited, on-demand pressure, very high control resolution and 10:1 pressure control turndown. Four different control modes are included for maximum versatility.
Open architecture allows reference pressure measurement to be internal to or remote from the controller. If desired, the reference can be located at the test measurement point and independently removed for recalibration.
With all of this, PPCH opens new doors in automated high pressure hydraulic calibration and test applications.
Quartz reference pressure transducer (Q-RPT) modules
PPCH’s outstanding pressure measurement specifications are made possible by the Fluke Calibration exclusive quartz reference pressure transducer (Q-RPT) modules.
Q-RPTs measure pressure by measuring the change in the natural oscillating frequency of a quartz crystal with pressure induced stress. To be qualified for use in a Q-RPT module, each transducer is individually evaluated and characterized using automated primary pressure standards. Only transducers exhibiting required levels of linearity, repeatability and stability are selected. A proprietary compensation model, derived from more than 15 years experience with thousands of quartz pressure transducers, is applied to op...
The piston gauge’s fundamental operating principle and excellent long term stability have made it an indispensable tool in high accuracy pressure metrology. As accuracy levels increase, quality assurance requirements intensify and automation spreads through the workplace, the piston gauge must evolve to continue to fill its essential role in the measurement system. PG7000, the first truly new, high end piston gauge introduced since the late 1970s, responds to this challenge.
PG7000 development was undertaken with four main inter-related design objectives:
• Deliver real improvements in fundamental metrological performance to assure that today’s and tomorrow’s ever increasing accuracy requirements can be supported.
• Integrate automated monitoring of environmental and instrument operating conditions with extensive on-board intelligence to provide a modern stand alone instrument that outputs fully validated reference pressures, real time, through an intuitive operator interface.
• Reduce and when possible eliminate the influence of the operator on measurements to assure more consistent performance.
• Improve piston gauge ergonomics for greater operator satisfaction and increased productivity.
The PG7000 design objectives were pursued with the refinement of existing techniques, innovative new design, process improvements and the thorough application of today's digital and information processing technologies. The result is a coherent line of piston gauges that sets a new standard for both performance and usability, redefining the state of the art in high end pressure metrology.
PG7601 is recommended for covering absolute and gauge pressures with gas including pressures near and under atmospheric pressure. PG7601 measurements can be referenced to vacuum by evacuating the bell jar that covers the mass load. If absolute and gauge pressures near and under the atmosphere are not required and/or pressure greater than 7 MPa (1 000 psi)is required, PG7202, ...
PPC4 is a stand-alone pressure controller intended for precision setting and control of gas pressure into a closed volume as is commonly needed for the calibration and testing of pressure measuring instruments. It has been designed to provide very high performance combined with maximum versatility and ease of use.
PPC4 can be equipped with a low cost utility sensor for pressure monitoring or one or two Quartz Reference Pressure Transducers (Q-RPTs) to allow it to set and measure pressure with very low measurement uncertainty. Up to two external Q-RPTs in an external Reference Pressure Monitor (RPM4) can also be integrated into a PPC4 system. In some cases, a barometer is included.
Pressure control is achieved by a patented pneumatic module based on digitally controlled solenoid valves and differential pressure regulators.
PPC4 is controlled locally by the operator using a front panel display, keypad and function keys or remotely by a computer using ASCII character command strings over RS232, IEEE-488.2 or Ethernet.
PPC4 models are available to measure and control pressure in ranges from as low as - 3 to 3 kPa to as high as 0 to 14 MPa in absolute, gauge and compound gauge measurement modes.
Quartz reference pressure transducer (Q-RPT) modules
PPCH’s outstanding pressure measurement specifications are made possible by the Fluke Calibration exclusive quartz reference pressure transducer (Q-RPT) modules.
Q-RPTs measure pressure by measuring the change in the natural oscillating frequency of a quartz crystal with pressure induced stress. To be qualified for use in a Q-RPT module, each transducer is individually evaluated and characterized using automated primary pressure standards. Only transducers exhibiting required levels of linearity, repeatability and stability are selected. A proprietary compensation model, derived from more than 15 years experience with thousands of quartz pressure transducers, is applied to optimize the metrological characteri...
The 7050LP low pressure digital pressure indicator, part of the versatile Series 7250 family, is specifically designed to meet the demanding performance requirements of calibrating low pressure sensors, transducers, mechanical gauges, portable calibrators and their plug-in modules. To accommodate bidirectional devices, the 7050LP can be supplied to operate in both positive and negative gauge modes. The 7050LP offers unmatched performance and measurement precision. Utilizing multiple ranges in a single instrument, the 7050LP combines precision, stability, and affordability. The 7050LP has a unique quartz sensor, the most accurate pressure sensing technology available in a digital pressure calibrator. Each quartz sensor is manufactured and tested to provide the ultimate performance required by a Fluke Calibration pressure calibrator, ensuring that every customer receives the highest quality, precision and stability in their instrument. Advanced precision The 7050LP is available in three different range configurations, each a dual range instrument. Select either the 10 inH20 and 30 inH2O combination, or the 20 inH2O and 60 inH2O or the 35 inH2O and 100 inH2O range combination. Each combination provides a precision to 0.005 % of reading from 10 to 100 % of the higher range. For pressures from 0 to 10 %, the precision is a fixed error equal to 0.005 % of 10 % FS. This unmatched precision is achieved by the unique quartz pressure sensing technology that puts the pressure in direct contact with the quartz element, eliminating mechanical linkages and metal diaphragms. Since this is a differential sensor, the reference side of the 7050LP can be connected to the reference side (low side) of the device under test. Therefore, disturbances due to room drafts, HVAC systems and opening/closing doors, which can have a detrimental effect on the calibration process, are eliminated. The 7050LP provides both unequalled precision and excellent long term stability due to the inherent pro...
The PG9607 is the next generation of absolute pressure piston gauge from Fluke Calibration. It supports the use of a 100 kg mass set to define gauge and absolute pressures from 11 to 500 kPa with a single piston-cylinder. The PG9602 is the next generation of absolute pressure piston gauge from Fluke Calibration. It includes multiple piston cylinder range options to support absolute or gauge pressure measurements from 12 kPa to 10 MPa. This piston gauge is designed for use as a true primary pressure reference in metrology and research institutes. Its performance is centered around a 50 mm piston-cylinder assembly with dimensional characteristics suitable for low-uncertainty dimensional traceability. The piston mounting post allows controlled clearance operation and reduced uncertainty on piston-cylinder temperature measurement. The new platform architecture promotes improved temperature stability around the piston-cylinder. PG9607 features AMH automated mass handling technology to allow fully automated testing in both gauge and absolute mode. Manual steps are removed from its operation, saving time and delivering metrological advantages. When AMH is coupled with automatic pressure control and computer software, repeated and extended tests become practical, making PG9607 a powerful calibration and research tool. PG9607 is the result of Fluke Calibration's extensive work with national metrology institutes (NMIs) to minimize pressure measurement uncertainty and years of supplying PG7000 piston gauges to NMIs and other top pressure metrology labs worldwide. PG9602/9607’s piston-cylinder assembly builds upon more than 15 years of design, manufacture and calibration of 50 mm piston-cylinders. PC-9607-5 is a 5 kPa/kg piston-cylinder with a stationary piston and floating cylinder design. Improved manufacturing and testing methods are used to produce a very low distortion assembly. The 50 mm piston-cylinder provides exceptional performance up to 500 kPa with a 100 kg mass loa...
7050/7050i Pressure Indicators
The Series 7050 digital pressure indicator expands upon the popular line of Series 7000 products such as the Series 7250 digital pressure controller and Series 7252 dual output pressure controller. The 7050 provides an instrument for applications that only require pressure measurement. Three models are available to meet a wide range of applications: Model 7050i with advanced percent of reading precision Model 7050 with a high performance-to-price ratio Model 7050LP for low pressure measurements The Model 7050i, 7050 and 7050LP all use a unique quartz sensor, the most accurate pressure sensing technology available. Each quartz sensor is manufactured and tested to provide the ultimate performance required by a Fluke Calibration pressure calibrator, ensuring that every customer receives quality, precision and long term stability in their instrument. Standard precision The Model 7050 offers an economical approach to high-accuracy pressure measurement, with a precision of 0.003 % of full scale. Various ranges from 0 to 5 to 0 to 1,500 psi (0 to 400 mbar to 0 to 100 bar) are available. For absolute mode operation, select either the barometric reference option, or the vacuum reference option, which requires an external vacuum pump connected to the reference port. The latter features an on-board vacuum sensor that allows automatic zeroing in absolute mode. Permanent absolute ranges to 50 psia (4 bar) are also available. Advanced precision The Model 7050i offers advanced percent of reading precision for increased capability with a single instrument, reducing the investment required to measure a wide pressure range. This model provides 0.005 % of reading precision from 25 % to 100 % of the instrument’s range. For pressures below the lower threshold of 25 %, the 7050i precision is 0.005 % of the lower threshold value. For example, a 100 psi (7 bar) Model 7050i provides 0.005 % of reading from 25 to 100 psi (1.7 to 7 bar); the precision for pressures from 0 to 25 psi (0 to 1.7 ...

-350x280.jpg)
-350x280.jpg)





-350x280.jpeg)