P5523 Liquid-to-Gas Media Separator
For high pressure pneumatic calibrations this unit interfaces with hydraulic deadweight testers providing a rateless liquid-to gas separation. Driven by a pneumatic pressure source (nitrogen bottle) and controlled by needle valves, high pressure gas is balanced against the liquid in a hydraulic deadweight tester through a series of fluid traps.
Note: since fluid mist may be transferred during operation we do not recommend this device for oxygen- safe instruments using an oil operated deadweight tester....
Fluke P5540 Metric Adapter Set:
Includes adapters: M14x1.5, M20x1.5, 1/8" BSP, and 1/4" BSP female.
Designed for use with Fluke P5500 series hydraulic and pneumatic comparison test pumps, excluding P5514B.
Fluke P5541 BSP Adapter Set:
Includes adapters: 1/8", 1/4", 3/8" and 1/2" BSP female.
Designed for use with Fluke P5500 series hydraulic and pneumatic comparison test pumps, excluding P5514B.
Fluke P5542 NPT Adapter Set:
Includes adapters: 1/8", 1/4", 3/8" and 1/2" NPT female.
Designed for use with Fluke P5500 series hydraulic and pneumatic comparison test pumps, excluding P5514B.
Fluke PK-P3000-ADPTR-STD Adapter Set:
Includes adapters: M14x1.5, M20x1.5, 1/8", 1/4", 3/8", 1/2" BSP and NPT female.
Designed for use with Fluke P3000 series series hydraulic and pneumatic deadweigth testers and Fluke P5500 series test pumps, excluding model P38хх and P5514B....
To calibrate gauges with the pressure connection on the rear (for example, panel mount gauges) in their correct operating position, an angle adaptor should be used. The angle adapter uses the standard gauge adapters and positions the gauges at 90º. The maximum working pressure of this unit is 10,000 psi (700 bar)....
This adapter mounts directly to the test port of the calibrator and allows for the calibration of two instruments at the same time, or the connection of a reference test instrument. Maximum working pressure is 10,000 psi (700 bar)....
The Fluke Model P5551 Pointer Remover/Punch is a specialized tool designed to efficiently remove and accurately refit the pointer of a pressure gauge. It is particularly useful for maintenance and calibration tasks involving pressure measurement devices....
This pneumatic comparison pressure comparator is designed for testing pressure measuring instruments against master test instruments.
This cost effective instrument provides precise control for important calibration requirements and include many features found in our popular line of pneumatic deadweight testers.
Features:
High pressure pneumatic operation
Screw press for fine pressure adjustments
High quality needle valves for fine controlTest port adapters which require no PTFE tape or wrenches
Sturdy carrying case with lid
Note: Unit requires pressure source (i.e. nitrogen bottle) for operation....
MPG2-H Manual Hydraulic Pressure Regulator
MPG2-H is a compact, easy-to-use and economical system for manually generating and adjusting pressure from atmosphere to as high as 200 MPa (30 000 psi) in systems where precise pressure adjustment is required.
MPG2-H is very well suited for use as the pressure generating and controlling component in calibration and testing systems using a digital or analog pressure indicator as a reference. It is also ideal for working with oil operated piston gauges. MPG2-H is the standard choice for manual pressure generation and control in a DHI PG7302 high performance oil operated piston gauge system in which power assisted or automated pressure control is not needed.
The MPG2-H is for pressure up to 200 MPa (30 000 psi). The MPG2-H-HV is for larger test volumes with a maximum pressure of 100 MPa (15 000 psi).
MPG2 includes three different means of filling, priming, generating and adjusting pressure.
Filling and priming are accomplished with a syringe style priming pump built into the reservoir cover. The priming pump draws fluid directly from the reservoir and injects it through MPG2 and out its test port, filling the test system and generating a low starting pressure.
The main generating and adjusting element is a screw press variable volume. Operation of the variable volume is smooth and silent, requiring low torque even at the highest pressures. The screw threads through the handle so the handle rotates in the same position as the piston moves. Piston position is clearly indicated on the top of the MPG2 housing. The variable volume is able to set pressure very precisely (typically within 0.01% of the set pressure). For extremely fine pressure adjustment (typically to within 0.001% of the set pressure) the test shut off valve is used as a miniature variable volume.
Two test ports with standard, high pressure gland and collar fittings are provided to connect the MPG2 to the system into which pressure is to be set. The test ports are on the top and rear...