Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

Orion Model 796M

- -80°C to 300°C, 470mm Immersion.

- The Isotech Hydra range of calibration baths have proved very successful since their introduction in 2003. These deep stirred liquid baths are suitable for the low uncertainty calibration of long thermometers including liquid in glass and extended length SPRTS.

- Can accept large Water Triple Point Cells

- Variable Cooling Power

- Low Filling Cost

Brief specifications


More details

The Isotech Hydra range of calibration baths have proved very successful since their introduction in 2003. The Orion range has been introduced to fit alongside the Hydra models. The Orion calibration baths offer deeper calibration volumes than the Isotech Hydra series with world class temperature stability. There is a high temperature model (30°C to 300°C) and a model with built in refrigeration (-40°C to 125°C). These deep stirred liquid baths are suitable for the low uncertainty calibration of long thermometers including liquid in glass and extended length SPRTS. The Orion unit has sufficient depth, 470mm (18.5”), to accommodate Isotech’s largest Water Triple Point Cells providing a cost effective sub mK calibration system. There are accessories to hold Mercury, Water, Gallium and Indium ITS-90 Fixed Point Cells. Isotech baths have always been designed for thermometer calibration, setting the standard for immersion depth versus filling costs. As the Orion requires just 8.5L of fluid it offers significant cost savings, both initial and the ongoing running costs, when compared to other larger volume baths. In operation the liquid level is within 10mm of the top lid allowing calibration of liquid in glass thermometers without the need for complicated accessories. In addition to using a monocular to aid reading the scale I-Cal Easy automatic calibration software can capture images with low cost digital webcams. The Isotech Orion range provides many features that laboratories need but which other manufacturers often cannot supply.


ВимірюванняГенерація (Імітація)


Orion Model 796M

- -80°C to 300°C, 470mm Immersion.

- The Isotech Hydra range of calibration baths have proved very successful since their introduction in 2003. These deep stirred liquid baths are suitable for the low uncertainty calibration of long thermometers including liquid in glass and extended length SPRTS.

- Can accept large Water Triple Point Cells

- Variable Cooling Power

- Low Filling Cost

Featured Products

9915-878 Protective transport case
9915-878 Protective transport case
9915-878 The protective transport case is designed for storage and safe transport of Additel ADT878 series temperature calibrators. The case has an impact-resistant body made of corrosion-resistant PP Alloy material and provides protecti...
Код: 9915-878
PROGRAPH Measurement Analysis Software
Software Designed to be used in conjunction with the 8000 Precision Multimeter Series and 8500 Low Thermal Scanner, ProGraph provides an instant solution for graphing stability, temperature and many other parameters. ProGraph is a 'plug and...
Код: PROGRAPH
POTTS – Oceanus-6 Model 580
POTTS – Oceanus-6 Model 580
The multi-functions of the Oceanus-6 is a unique concept from Isotech, so unique that it is currently the subject of a patent application. The Oceanus-6 is a complete calibration laboratory working over the temperature range 45°C below ambi...
Код: 580
Miniature Fixed Resistor Model 836
Isotech produces a miniature resistor with ultra-low temperature coefficient and ultra-high stability. This is achieved because the resistors are oil filled and hermetically sealed. The function of hermetic sealing is to eliminate the ingre...
Код: 836
I-Cal EASY
I-Cal EASY
Use I-Cal Easy to automate sensor calibration, enter up to 20 calibration points and let the software set the bath, wait for stability and log the data automatically. Choose the stability criteria and how many points to record at each calib...
Код: EASY
9333 SERIES of Air Resistance Standards
9333 SERIES of Air Resistance Standards
GUILDLINE INSTRUMENTS NEW 9333 SERIES of Air Resistance Standards are cost effective laboratory, portable or just general purpose resistance standards. They are very stable and are designed to be used across a wide temperature range. PRODUC...
Код: 9333
ITS-90 Optimal Fixed Point Cells
ITS-90 Optimal Fixed Point Cells
Isotech Ultra Pure-Metal Freezing Point Cells are designed specifically to realize the liquid-solid equilibrium temperatures of certain high-purity metal elements, for calibration of thermometers at the ITS-90 Fixed Points. When you purchas...
Код: ITS-90
Additel 878 Reference Dry Well Calibrator
Additel 878 Reference Dry Well Calibrator
Additel takes temperature calibration to the next level with the ADT878 reference dry block calibrators. If you're looking for the best dry-block calibrator on the market, you've found it! Additel's commitment to continuous improvement, qua...
Код: ADT878-160
Multi Junction Laboratory Probes
Multi Junction Laboratory Probes
Probes are suitable for use with all Isotech thermocouple reference units or may be used with any other equipment including ice flasks and ice point reference units. They can be supplied to suit a single thermocouple, or up to ten double ju...
Код:
Temperature Controlled Fixed Resistors
Temperature Controlled Fixed Resistors
By temperature controlling an otherwise very stable resistor a performance close to the very best available World-wide can be achieved at a surprisingly low price. The resistor itself is oil filled and hermetically sealed. The function of h...
5.0000/5 1text_less_review
Код:
7810 WIDEBAND TRANSCONDUCTANCE AMPLIFIER
7810 WIDEBAND TRANSCONDUCTANCE AMPLIFIER
GUILDLINE INSTRUMENTS 7810 WIDEBAND TRANSCONDUCTANCE AMPLIFIER is the latest innovation for High Current, Wide Bandwidth AC Outputs. PRODUCT FEATURES 50 A and 100 A Models Calibrated Frequency Range (DC to 100 kHz) Uncalibrated 100 kHz to 2...
Код: 7810
PPCH High-Pressure Controller
PPCH High-Pressure Controller
PPCH™, is a pressure generator/controller/calibrator for liquid pressure operation from 1 to 200 MPa. As with the rest of the Fluke Calibration PPC family of pressure controllers, the emphasis is on high end performance, minimizing measurem...
Код: PPCH
Oxygen Combustion Control Analyzer - Michell XZR500
Oxygen Combustion Control Analyzer - Michell XZR500
The XZR500 oxygen analyzer from Michell Instruments is designed to determine the excess air required for optimum combustion. It uses advanced Zirconium Oxide technology to measure levels of oxygen in harsh conditions such as boilers, incine...
Код: XZR500
ADT158Ex Digital Pressure Modules
ADT158Ex Digital Pressure Modules
With advanced microprocessor technology and state-of-the-art silicon pressure sensors, Additel’s 158Ex series Digital Pressure Modules provide an accurate, reliable, and economic solution for wide range of pressure applications. Our intrins...
Код: ADT158Ex
ADT916A Pneumatic Pressure Test Pump
ADT916A Pneumatic Pressure Test Pump
The 916A Pneumatic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 600psi (40bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to...
Код: ADT916A
Standard Thermocouple Model 1600
Standard Thermocouple Model 1600
The Isothermal range of Thermocouple Standards are the result of many years development. The type R and S standards will cover the range from 0°C to 1600°C. The measuring assembly comprises a 7mm x 300mm or 600mm gas tight 99.7% recrystalli...
Код: 1600
MC620G Module Carrier
MC620G Module Carrier
The MC620 module carrier attaches to the head of the DPI620 to provide two independent pressure measurement channels. These can be fitted with any PM620 pressure module from 25 mbar to 1,000 bar (10 inH2O to 15,000 psi). A simple screw fit ...
Код: MC620G
Parallel Tube Liquid Bath Model 915MWE
Parallel Tube Liquid Bath Model 915MWE
The Isotech Model 915 Liquid Bath is suitable has a wide temperature range, using silicon oils and other suitable liquids. All components in contact with the liquid are of stainless steel, and are insulated with materials which are complete...
Код: 915MWE
CAL NotePad
CAL NotePad
The purpose of Cal NotePad (CNP) is to automatically log and display the temperature of an Isotech calibration bath together with the unit under test. Cal NotePad can be used with baths (or indicators) without PC interfaces by the user typi...
Код: ePad
3041A precision multiproduct calibrator
3041A precision multiproduct calibrator
The 3000A Series multiproduct calibrators have been designed to help you and your business, allowing a wide range of calibration work to be performed quickly, accurately and economically. Modern calibration is a competitive market, and cost...
Код: 3041A
Спасибо!