Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

Model 944

- 30°C to 350°C

- The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from the surface of the hot-plate causes a localised cold spot to be created which means that the temperature indicated by the hot plate is not necessarily the temperature at the point of measurement.

- Indicates True Surface Temperature

- 30°C to 350°C

- Resolution 0.1°C

Brief specifications


More details

The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from the surface of the hot-plate causes a localised cold spot to be created which means that the temperature indicated by the hot plate is not necessarily the temperature at the point of measurement. An ideal system would not disturb the heat-flux from the hot-plate. During 1993 such a system was described (ref. “Progress in Contact Thermometry” 1993 B. D. Foulis) and Isotech have the inventor’s permission to make and market the device World-wide. Principal of Operation A fine wire type N thermocouple is used as the surface temperature sensor, a second junction 2 to 3mm along the thermocouple, senses the temperature difference due to heat flux along the sensor. A heater heats the thermocouple stem until the temperature gradient is zero, thus creating a measurement without stem conduction, or disturbance of the hot-plate’s surface. The 944 can be used with the Isotech Small Hot Plate model 983. A traceable calibration certificate is available to order.


ВимірюванняГенерація (Імітація)


Model 944

- 30°C to 350°C

- The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from the surface of the hot-plate causes a localised cold spot to be created which means that the temperature indicated by the hot plate is not necessarily the temperature at the point of measurement.

- Indicates True Surface Temperature

- 30°C to 350°C

- Resolution 0.1°C

Featured Products

7252/7252i  Pressure Controllers
7252/7252i  Pressure Controllers
Adding to the flexibility of the Series 7252, two performance models are available: the Model 7252i that offers percent of reading performance further extending the capabilities of a single calibrator, or the Model 7252, that provides perce...
Код: Fluke 7252
DPS5000 Series  Digital Pressure Sensors
DPS5000 Series  Digital Pressure Sensors
The DPS5000 I2C from Druck, part of the UNIK5000 family, offers integrated digital electronics to enhance the performance level of the UNIK5000 Pressure Sensing Platform to levels unmatched by traditional analog sensors. It features an I2C ...
Код: DPS5000
Ice mantle maker for water triple point cells
Ice mantle maker for water triple point cells
Are you fed up with cold wet hands, and hours of frustration when you produce an ice mantle in your Triple Point Cell? Change your life and try the Isotech Ice Mantle Maker. It works by using a specially designed anti-gravity heat pipe. The...
Код: Ice mantle
QuickCal Blackbody
QuickCal Blackbody
When the high accuracy of the Gemini R is not necessary this product offers a cost effective solution for the calibration and testing of infrared thermometers. The QuickCal Blackbody is ideal for rapid and portable checking of infrared ther...
4.8182/5 11text_less_review
Код: QuickCal Blackbody
xTHP Hydraulic Calibration Test Pumps
xTHP Hydraulic Calibration Test Pumps
Whenever a high pressure calibration pump is needed, we offer several portable, hydraulic test pump models designed to work seamlessly with a reference gauge and process connection. The QTHP reaches test pressures up to 5000 psi (35 MPa) wh...
Код: xTHP
Flexible Current Probe SymmProFlex FCP 3x21
Precision Flexible AC Current Probes SymmProFlex® FCP 3121 and FCP 3321 are current probes based on Rogowski principle designed to measure alternating current up to 3000 A, 6000 A, 12000 A or more. Current Probes SymmProFlex® FCP 3121 (sing...
Код: SymmProFlex
PM700E External Pressure Sensors
PM700E External Pressure Sensors
PM705E is a remote pressure module designed for high-precision pressure measurement of liquid and gaseous media in industrial and laboratory applications. The module provides reliable data readings under conditions of increased vibration an...
Код: PM700E
Dew-Point Hygrometer - Michell Easidew Online
Dew-Point Hygrometer - Michell Easidew Online
Easy to install and maintain, the Easidew Online Hygrometer measures and displays dew point and moisture content for use in a wide range of moisture applications. The Easidew Online display provides analog, digital, and dual relay alarm out...
Код: Easidew Online
IO620-COMP Comparator adaptor
IO620-COMP Comparator adaptor
Comparator adaptor Allows the PV62XG pressure station to be used as a comparator. The adaptor connects to the stations pressure port and provides two outlet ports for making gauge comparisons. Compatible with the test point adaptors supplie...
Код: IO620-COMP
PROCAL -TRACK laboratory management software
PROCAL -TRACK laboratory management software
ProCal-Track provides tools for the management of instruments from goods inwards through to despatch and all points in between. ProCal-Track can be used independently of ProCal, or can be integrated for full laboratory automation. Ease of u...
Код: PROCAL
Self-Contained Hygrometer- Michell Drycheck
Self-Contained Hygrometer- Michell Drycheck
A simple and efficient, self-contained dew-point hygrometer, with filtration and flow control, for measurement of dew point or moisture content at point of use. It uses the Easidew On-Line to measure dew point in the range –100 to + 20 °C d...
Код: Drycheck
Drago 4934
Drago 4934
Need advice on which model? Dry Block Selection Guide The Hyperion and Drago have large calibration volumes, 65mm x 160mm deep, which makes them ideal to use as portable liquid baths. Stirred liquid baths are suitable for temperature sensor...
Код: 4934
AII GPR-3500 MOVR Portable Purity Oxygen Analyzer
The GPR-3500 MOVR Portable Oxygen Purity Analyzer is the only electrochemical oxygen sensor based analyzer capable of measuring 100% oxygen on a continuous 24/7 basis for the purpose of verifying the purity of medical grade oxygen transport...
Код: GPR-3500
9915-878 Protective transport case
9915-878 Protective transport case
9915-878 The protective transport case is designed for storage and safe transport of Additel ADT878 series temperature calibrators. The case has an impact-resistant body made of corrosion-resistant PP Alloy material and provides protecti...
Код: 9915-878
IO620-CASE-1 Carrying case
IO620-CASE-1 Carrying case
Carrying case Protective carrying case with belt loop, shoulder strap and large detachable pocket for test leads and accessories...
Код: IO620-CASE-1
IOHOSE-NP1 Pneumatic hose
Pneumatic hose terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. Safe area use 1 m/3.28 ft pneumatic hose. Maximum pressure 20 bar/300 psi...
Код: IOHOSE-NP1
ADT12X Pressure Manifolds
The 12X series pressure manifolds are designed for expanding pressure test ports during pressure calibration. The Additel 121 pressure manifold is used for pneumatic pressure calibration up to 3,000 psi (200bar), while the Additel 123 mani...
5.0000/5 2text_more_review
Код: ADT12X
ADT680P Digital Pressure Gauge
ADT680P Digital Pressure Gauge
Additel’s 680P Series Digital Pressure Gauges are designed to be used in panel mount applications. With features such as data logging (optional) and Bluetooth technology included, you will find these gauges to be high in value at a reasonab...
Код: ADT680P
IO620-MET A set of test point adaptors
IO620-MET A set of test point adaptors
A set of test point adaptors to connect the tool less quick fit PV62XG, MC620G and the extension hoses to the device under test...
Код: IO620-MET
Fast-Cal Low
Fast-Cal Low
Fast-Cal – the product range you designed During early 2004 20 experienced engineers from many parts of the world were asked to produce their ideal specification for industrial calibration. Their top ten requirements, in order of priority, ...
Код: Low
Спасибо!