Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

CAL NotePad

- The purpose of Cal NotePad (CNP) is to automatically log and display the temperature of an Isotech calibration bath together with the unit under test. Cal NotePad can be used with baths (or indicators) without PC interfaces by the user typing in values from the keyboard.

Brief specifications


More details

The purpose of Cal NotePad (CNP) is to automatically log and display the temperature of an Isotech calibration bath together with the unit under test. Cal NotePad can be used with baths (or indicators) without PC interfaces by the user typing in values from the keyboard. The Cal NotePad can be used to identify the operator and the unit under test. With the click of a button data is logged with time information, it is also possible to log continually. The calibration bath temperature can be changed from the PC or from the calibration baths controller – Cal NotePad will display the temperature changes as they occur on the re-scalable chart display. For traceable calibration the unit under test should be compared to a calibrated standard thermometer. Cal NotePad can record the actual temperature of the bath from either the in-built indicator of an Isotech SITE model or from a variety of external instruments see list. If the external instrument has two channels (e.g. Isotech TTI) then the unit under test may be connected to channel B for logging with CNP. Alternatively the value can be typed in from the keyboard. Similarly the calibration bath controller value, actual temperature, SITE indicator value or unit under test value may also be entered manually. Then the manually entered data is combined with that gathered automatically and the resultant file can be opened in an external application such as Excel for the preparation of reports, certificates etc. Cal NotePad is designed for ease of use, it will give a chart of the system. When the operator determines the system is stable – easily seen from the chart then clicking a button will record time, operator, serial numbers of unit under test along with controller and indicator values. Cal NotePad can be used for semi-automatic calibration, see I-Cal Easy for a fully automated calibration solution.


ВимірюванняГенерація (Імітація)


CAL NotePad

- The purpose of Cal NotePad (CNP) is to automatically log and display the temperature of an Isotech calibration bath together with the unit under test. Cal NotePad can be used with baths (or indicators) without PC interfaces by the user typing in values from the keyboard.

Featured Products

Terminal Adapter Model 956
Terminal Adapter Model 956
Our TTI range use high quality ‘Lemo’ connectors for the Pt100 inputs. This simple accessory provides 4mm Terminal Posts for the connection of bare wires, spade terminals or 4mm plugs – useful if a lot of probes are going to be used with th...
4.5000/5 2text_more_review
Код: 956
ISOTowers
ISOTowers
The most accurately defined temperatures are those defining points (fixed points) of ITS-90. The leading Primary Laboratories use large fixed point cells in deep calibration furnaces that utilise heat pipes to eliminate temperature gradient...
Код: ISOTowers
DCAP Pneumatic Scissor Hand Pumps
DCAP Pneumatic Scissor Hand Pumps
Manual pneumatic pumps Ralston DCAP are reliable tools for precise pressure calibration, designed to perform in a wide range of environments. With their straightforward and intuitive design, these pumps are an ideal choice for both laborato...
Код: DCAP
Humidity Temperature Probes - Rotronic HC2A-S/S3/SM
The HC2A series are digital humidity-temperature probes based on the AirChip3000 technology. These probes feature a UART serial interface and two 0…1 V linear analog output signals. The HC2A probes are designed for use with the HygroClip2...
Код: HC2A-S/S3/SM
6624CT-3000 DC High Current Transformer
6624CT-3000 DC High Current Transformer
Guildline's 6624CT-3000 DC High Current Transformer provides very accurate DC current measurements up to 3000 Amperes. The direct current transformer is designed with an open window to pass a single cable, set of cables, or buss bar that ca...
Код: 6624CT-3000
Chilled Mirror Hygrometer - Michell S8000 Remote
Chilled Mirror Hygrometer - Michell S8000 Remote
The S8000 Remote is a compact chilled mirror hygrometer with a remote sensor. It provides it provides fundamentally derived, high precision relative humidity readings necessary for validating the results of environmental tests. It offers a...
Код: S8000 Remote
Additel Land DataStored Software
With Additel/Land software, you may download test results stored in the internal memory of Additel calibrators to a PC, and export the results to an excel file. It is a free software package...
Код: Land
AA405F Accessories to ADTS
AA405F Accessories to ADTS
Includes a range of accessories from power cables to extended hoses and more...
Код: AA405F
Precision Electronically Compensated Current Transformer CMR-I ™
Precision Electronically Compensated Current Transformer CMR-I ™
Other Features The CMR-I 2x30 is equipped with Load Monitoring, Protection Circuits and Load Bypass via serial remote control. The CMR-I can be implemented into any existing test system with negligible additional power losses. Current ratio...
Код: CMR-I
4610M ADVANCED MULTIPRODUCT CALIBRATOR
4610M ADVANCED MULTIPRODUCT CALIBRATOR
4610M DC VOLTAGE 0 - ±1025V DC CURRENT 0 - 30A AC VOLTAGE 2mV - 1000V, 10Hz - 1MHz AC CURRENT 20uA - 30A, 10Hz - 30kHz RESISTANCE (PASSIVE) 0 Ohms - 1 GOhm CAPACITANCE (PASSIVE) 1nF - 10uF FREQUENCY 10Hz - 1MHz TEMPERATURE (THERMOCOUPLE) J ...
Код: 4610M
2468A Pitot/Static Primary Standard
2468A Pitot/Static Primary Standard
The Model 2468 Pitot Static Primary Standard is specifically designed for calibrating today’s high performance flight line and Air Data Test Systems. With the new autofloat controller, operator intervention is reduced to simply applying the...
Код: 2468A
PM200, PM500, PM600 Pressure Modules
PM200, PM500, PM600 Pressure Modules
PM200 Pressure Measurement Modules Key features: - 0.02% FS specification makes it ideal for calibrating or testing pressure dial gauges, lower accuracy transmitters, or pressure switches. - Rugged silicon pressure sensor design allo...
Код: PM
AII GPR-2500 Percent Oxygen Analyzer
AII GPR-2500 Percent Oxygen Analyzer
The GPR-2500 is a wall-mounted Industrial Acid Analyzer for acid measurement in both general-purpose and explosion-proof rooms. Wide choice of housing construction plastic, metal, aluminum and different finishes for standard and non-danger...
Код: GPR-2500
Dew-Point Transmitter - SF52
Dew-Point Transmitter - SF52
The SF52 dew-point transmitter is a simple, cost effective moisture sensor designed for use in harsh industrial dryer applications. It is reliable and tough enough to withstand the high temperatures often associated with industrial drying. ...
Код: SF52
Flexible Current Transformer FCT 2161
Flexible Current Transformer FCT 2161
Precision Flexible AC Current Transformer SymmProFlex® FCT 2161 is based on Rogowski principle designed to measure alternating current and to transform the measured current to standardized 5 A level...
Код: 2161
Medusa R Model 999
Medusa R Model 999
The Medusa R Blackbody Calibration Source allows for calibration of noncontact infrared thermometers over the temperature range 30°C to 550°C. It is suitable for use as a radiation source for infrared thermometers. The cavity is 45 x 285mm ...
Код: 999
Gallium Fixed Point Apparatus
Gallium Fixed Point Apparatus
Model 17402B Gallium Apparatus is not an adaptation from general purpose equipment, but is designed specifically to realize and maintain the Gallium Cell on the melt plateau, for calibration of thermometers on the International Temperature ...
Код:
2271A Pressure Controller & Calibrator
2271A Pressure Controller & Calibrator
The Fluke Calibration 2271A Industrial Pressure Calibrator provides a complete, automated solution for calibrating a wide variety of pressure gauges and sensors. Thanks to its modular design, it can be configured to meet different needs and...
Код: 2271A
Jupiter 4852
Jupiter 4852
Need advice on which model? Dry Block Selection Guide The Jupiter Dry Block range offers industry-leading performance in an easy to use portable package – ideal for the calibration of thermocouples and platinum resistance thermometers. It h...
5.0000/5 1text_less_review
Код: 4852
Large Volume Liquid Bath Model 820
Large Volume Liquid Bath Model 820
If you have a large number of sensors to calibrate then this economically priced stirred liquid bath is the solution. The 820 bath has been introduced to provide a liquid calibration bath with a large volume. This is to allow the bath to be...
5.0000/5 1text_less_review
Код: 820
Спасибо!